Protection Relay
acts as a circuit breaker in the event of a fault.
-
Product
Epoxy Resin Silicon Rubber Outdoor Voltage Transformer
JDZW-10RG
-
Beijing GFUVE Electronics Co.,Ltd.
Outdoor voltage transformer of the type JDZW-10 is single phase and epoxy resin silicon rubber insulated product, it's used for metering electric energy, voltage control and relay protection in 50/60HZ rated voltage less than 12kV electric system. It can be used for medial voltage AIS, or can be used for medial voltage switchgears. They can operate in all kinds of environments (such as wide range temperature (-50~70℃), high altitude, high humidity, high pollution or salt). This model JDZW-10 outdoor voltage transformer is also as voltage source to supply 220V voltage.
-
Product
NI TB-2646B Terminal Block for NI 2532B as 1-Wire Quad 4x32 or 2-Wire Dual 4×32 Matrix Matrix Topology Without Column Protection Resistors
782385-13
Terminal Block
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
Protection Testing Library
-
The OMICRON software technology including the OMICRON Control Center, XRIO, and LinkToXRIO enables users to create specific test templates which adapt automatically to the actual relay settings. This functionality is the technological basis of the Protection Testing Library (PTL), a comprehensive test template library for a wide range of protection relays.
-
Product
Portable Relay Tester
-
The protective devices such as relays, overload coils, circuit breakers must be checked regularly to ensure that, they are always ready to operate correctly. If a fault occurs in the equipment, which they are protecting, routine relay testing will quickly detect the faulty, incorrectly adjusted protection circuit and will possibly prevent serious damage to plant or injury to personnel. Apart from checking the protective circuits correctly, it is usually necessary to measure its operating time. The micro controller based time interval meter is used for this purpose in all AJIT brand relay tester.
-
Product
NI TB-2646B Terminal Block for NI 2532B as 1-Wire Quad 4x32 Matrix topology With Column Protection Resistors
782385-14
Terminal Block
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
Product
Three-Phase Relay Protection Tester
GDJB-PC
-
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
1.GDJB-PC Universal Secondary Injection Relay Test Set is applied to test the relay unit in relay protection system. 2.At the same time GDJB-PC Universal Secondary Injection Relay Test Set could be considered as a universal three phase AC/DC voltage source or current source. 3.It can work alone or connected to computer, inside the relay controller there are new speed digital signal mini PC and real DAC (Digital-to-Analog Converter) template with new high fidelity and high power, the machine has large panel screen and rotating mouse. It is small in volume, high precision.
-
Product
IEC61850 Relay Test Set
NF802
-
NF802 is full digital IEC61850 relay test set, equipped with 8 optical ports, and powerful data processing capability, can realize full digital IEC61850 protection relay testing.
-
Product
Relay And Protection Testing
-
As the first protection relay test set manufacturer in China, PONOVO has been always offering reliable protection relay testing equipment for customer for more than 20 years. More than 20,000 relay test kits has been supplied to users in China and other countries, including 6-phase, 3-phase, single phase relay test sets, capable of testing all kinds of protection relays, from electromagnetic relays, solid state, numerical, microcomputer relays and digital relays based on IEC61850 as well as other testings, such as, energy meter, transducer, etc. With various models with different specifications, users can definitely choose the model suitable for their testings.
-
Product
Protective Relay Test System
MTS-5100
-
The MTS-5100 is the only all-in-one relay test set with a direct front panel interface for all functions, without exception!
-
Product
Protective Relay Test Set
POM2-6143
-
POM2 series protective relay test equipment is the best modular designed relay tester with local control system. There are 2 models, the POM2-6143 and POM2-3243, the POM2-6143 with 6×15A and 4×300V.
-
Product
Secondary Injection Equipment for Relay Testing
-
Portable equipment to test all types of protective relays and power system protection schemes. Automatic relay testing software, Comtrade transient playback and test reporting.
-
Product
Transformer Demagnetization Tester
-
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
Product
Advanced Line Protection System
ALPS
-
ALPS is a multi-function digital protective relay system intended toprovide distance protection for HV or EHV transmission lines. It maybe applied on or adjacent to series compensated lines. It is availablefor single or three phase tripping applications. Typical operatingtimes are to 1 cycle.
-
Product
Primary Current Injection
PCI-600
-
The VIC Model PCI-600 is a programmable, high-current source that is designed specifically for utility-substation applications. This alternating current(ac) test device is used primarily for injection testing of protective relays. This same device can also be used for testing thermal, magnetic and solid-state motor-protection relays and molded-case circuit breakers.
-
Product
Enlarge Environmental Chamber
REXMED REC-450
-
MOD. REC-450, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,644 Watts, 12,433 BTU/hr, 3,140 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
Product
20Hz Generator
-
Signals & Systems India Private Limited
In order to implement a 100 % stator earth fault protection based on subharmonic injection, a 20Hz voltage is injected into the generator star point. The 20-Hz generator SGEN-1001 is used in combination with the Band Pass Filter SBPF-1001 in the Stator Earth fault protection. The injection can be performed by connecting the SGEN-1001 and the SBPF-1001 to the load resistor of an earthing or neutral transformer. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. From the driving voltage and the fault current, the protective relay determines the fault resistance.
-
Product
Protective Cover, I2 MX, Receiver, EMI-Shielded
310113667
Protective Cover
Protective Cover, i2 MX, Receiver, EMI-Shielded
-
Product
Protective Cover, 9025, 9025VXI & 9025TR, ITA
410112578
Protective Cover
The ITA Protective cover is made up of aluminum making it more durable and shock resistant to protect your contacts and modules when the ITA is not in use.
-
Product
Protective Cover, Mini Fiber Optic, Receiver
510109501
Protective Cover
For use with modules p/n 510104243 and 510104120.
-
Product
Protective Cover, S6, Receiver
310113432
Protective Cover
The Receiver Protective cover is designed to protect your modules and contacts while the test system is not in use.
-
Product
Protective Cover, G12, Receiver
310113402
Protective Cover
The Receiver Protective Cover prevents damage to your modules and contacts and keeps your test system in proper working order.
-
Product
Protective Cover, G18, Receiver
310113327
Protective Cover
The Receiver Protective Cover is provided to keep your modules and contacts enclosed to prevent damage, keeping your test system in proper working order.
-
Product
Replacement Protective Cover, G12, ITA, Vinyl
410112681
Protective Cover
The ITA Protective Cover protects your contacts and modules. An ITA Protective Cover is included with the G12 ITA.
-
Product
Protective Cover, G10, Receiver
310113154
Protective Cover
The Receiver Protective Cover is optional to keep your modules and contacts enclosed when the Receiver is not in use.
-
Product
Replacement Protective Cover, ICon, Receiver
310113460
Protective Cover
The receiver protective cover is designed to protect your modules and contacts while the test system is not in use. A protective cover is included with the iCon Receiver. The receiver protective cover comes with a beaded chain and mounting hardware.
-
Product
Protective Cover, G20, 6.75" Series Adapters, Receiver
310113422
Protective Cover
Protective Cover, G20, 6.75" Series Adapters, Receiver
-
Product
Protective Cover, 75 Module, Receiver
310113352
Protective Cover
The Receiver Protective Cover is available and encloses your modules and contacts when the ITA is not engaged.
-
Product
PXI Power Relay Module, 16xSPST, 16 A, With Interlock
40-161A-001-HI
Relay
The 40/42-161A-001-HI is a PXI/PXIe 16xSPST power relay module with optional hardware interlock. It is part of a range of high density power switching solutions with a choice of SPST, and SPDT relay configurations with or without hardware interlock.
-
Product
PXI/PXIe Microwave Relay, Single SPDT, 110 GHz, 50 Ω, SMA-1.0, External Termination, Latching
42-781A-921-LA
Relay
Externally terminated switches have the advantage that the terminations can be removed and replaced with higher power RF loads. This also allows alternative configurations such as terminated 4-port bypass (1 termination removed) and 5-port DP3T (both terminations removed). See the datasheet for diagrams of these configurations.





























