High Frequency
High Frequency operating at 3–30 MHz.
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
High Frequency Probe
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
Product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03B-006
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Dielectric VTE Rating (k VAC): 1Nominal Impedance (Ohms): 50Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
Product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03G-003
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
Product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
High Frequency Probe
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes
-
Product
Active Differential Probe, 100 kHz to 7 GHz
U1818A
High Frequency Probe
The Keysight U1818A 100 kHz to 7 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818A allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40G-021
High Frequency Probe
Your product description goes here.
-
Product
High Frequency (RF) Testing
-
C.C.P. Contact Probes Co., LTD.
CCP designs high frequency testing probes, coaxial probe sockets and pressurized conductive rubber sockets.
-
Product
High Frequency Connectors
-
C.C.P. Contact Probes Co., LTD.
CCP is an expert in the design of high frequency connectors. We offer 5G ready connectors and USB 3.2 connectors.
-
Product
High-Frequency Test Coil
-
West Coast Custom Designs, LLC
is most commonly used by the neon industry for detecting leaks in a pumping system; the spark generated by the coil via the solid tip, will enter the tube through the leak and become bright white at the point at which it enters.
-
Product
Ultra High Frequency Vibrometer
UHF-120
-
Polytec?s New UHF-120 Vibrometer Laser-Doppler Vibrometers (LDV) can characterize the out-of-plane vibrations at ultra-high frequencies. Polytec?s UHF-120 extends the vibration frequency bandwidthup to 600 MHz.
-
Product
High Frequency Current Transformer
HFCT Ø 140mm
-
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
Product
High-Frequency Ultrasonic Imaging System
USPC 3060 UHF
-
Ingenieurbüro Dr. Hillger Ultrasonic-Techniques
The ultrasonic imaging system USPC 3060 UHF is optimized for the testing wih high frequencies and delivers high resolution B-, C-, Dand F- scans. It consists of a scanning system with water tank and the external pulser-/receiver module as well as a 19”-rack with scanner controller and the ultrasonic system and monitor, keyboard and mouse.
-
Product
High Frequency/Microwave
-
SemiProbe high frequency probing solutions provide a broad array of capabilities for measurements ranging from DC to over 300 GHz. We design PS4L systems for high frequency applications with carefully selected components including chucks, probe arms, probes, cables, tuner modules, and calibration suites that are optimized for the frequency range that the application will operate in.
-
Product
High Frequency Chambers
-
Specialized, shielded rooms designed to absorb electromagnetic reflections.
-
Product
High-Frequency Amplifiers
-
Tabor’s line of High-Frequency Amplifiers allows for a better, more advanced utilization of the already available digital outputs on some of Tabor’s arbitrary waveform generators.
-
Product
High-Frequency Switch
VCH-604
-
High-Frequency Switch VCH-604 is designed for switching high-frequency (1 – 100 MHz) and pulse TTL signals. VCH-604 contains two groups of channels; each group has 25 inputs and 2 outputs. VCH-604 can be controlled from PC via GPIB and RS-232 interfaces or directly from front panel.
-
Product
RF High Frequency Probes
High Frequency Probe
*Low impedance*High bandwidth up to 20 GHz*Repeatable measurements*Coaxial design*Interchangeable center conductor
-
Product
Signal Generator High-Frequency GSM AXIe
-
The hardware-software complex "High-frequency GSM signal generator AXIe" is designed to generate harmonic sinusoidal signals with analog modulation (AM, FM, PM, IM) or without modulation in the frequency range from DC to 10 GHz.
-
Product
High Frequency Retrofits and Relocations
-
Our services also include upgrades of existing HF chambers to meet new program requirements, absorber installations, and relocations of chambers from one site to another.
-
Product
High Frequency Synthesizer
HFS Series 1.25” x 1” x 0.25”
-
*Surface Mount Package *Broadband Designs Available *Optional Internal Reference *Optional Reference Detect Switch *Internal Reference Output Available *Off-the-Shelf Products Available
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75R
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
Product
High Frequency Spring Probes
-
We have spring probes for high frequency for 0.5 and 0.8mm pitch. We provide spring probe with low insertion loss by shorten the total length to 1.5mm (use length 1.1mm).
-
Product
Cable Assembly, Receiver, High Frequency, 20", 10 SMA Plugs
540153010112
Cable Assembly
Cable Assembly, Receiver, High Frequency, 20", 10 SMA Plugs
-
Product
Signature Model High Frequency Surge Testers
S
-
Bench size performance & durability with PJ's exclusive/unique High Frequency Technology capable of testing the integrity of any turn to turn insulation, including low inductance windings. These Digital Surge Testers come standard with a rack-mounted, Tektronix TDS1002, 1 Billion Samples/sec, real time, programmable, storage oscilloscope.
-
Product
Standard 3.27 (93.00) - 8.13 (231.00) High Frequency Probe
K-50L-QG
High Frequency Probe
Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 0.80Nominal Impedance (Ohms): 50Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 225Recommended Travel (mm): 5.72Overall Length (mil): 1,830Overall Length (mm): 46.48
-
Product
High Frequency Coaxial Analytical Probes
-
D-COAX offers four analytical probe models: HyPac model for package characterization, and two models, Omni and OmniJet, for board level characterization, and DP1.4mm differential, single-ended probe.
-
Product
1202a High Frequency Distribution
-
Precise Time and Frequency, Inc.
The ptf 1202A High Frequency Distribution amplifier provides high performance frequency references for laboratory or system use requiring distribution at frequencies of 30MHz and above.The ptf 1202A is especially designed to distribute the high frequency input signal to 12 separate outputs, with minimum signal distortion and maximum isolation between individual output signals.
-
Product
High-Frequency Probe, 300 kHz to 3 GHz
85024A
ICT/FCT Probe
85024A high-frequency probe makes it easy to perform in-circuit measurements. An input capacitance of only 0.7 pF shunted by 1 megohm of resistance permits high frequency probing without adversely loading the circuit under test. Excellent frequency response and unity gain guarantee high accuracy in swept measurements with this probe. High probe sensitivity and low distortion levels allow measurements to be made while taking advantage of the full dynamic range of RF analyzers.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
High Frequency Probe
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes