Filter Results By:
Products
Applications
Manufacturers
-
product
Military-Style DC Solid-State Relay for High-Current Pulse Load Applications
Part No. M33-2N
The M33-2N is a military-style DC solid-state relay designed for high-current pulse load applications. It features the latest power FET output technology to minimize ON resistance. This feature provides minimum output voltage drop and allows the M33-2N to switch high pulse currents up to 100 amps at higher temperatures than those allowable with bipolar devices. The M33-2N utilizes transformer isolation to protect against transients, and are through-hole mountedMSL 1 Available options include:M33-2 7Adc, 60Vdc Load; 4.5-5.5Vdc (bias voltage), 80µA (CMOS) Control;
-
product
JFET Input Amplifiers
Analog Devices JFET input op amps or FastFET high speed (>50 MHz) input op amps provide high input impedance and ultralow input bias currents for high speed applications. The majority of our FET input op amps feature wide supply ranges from +5 V to 12 V or higher and feature rail-to-rail outputs enabling wide dynamic range.
-
product
Low Input Bias Current Op Amps (≤100 pA)
Low input bias current op amps are required whenever the difference of currents or voltage is small and needs to be measured accurately. These op amps are used so that the signal is not loaded down by the input of the op amps. Low input bias current op amps are critical for interfacing sensors in applications from photodiodes, pH meters, or other electrometer related functions to downstream electronics. Analog Devices has many precision op amps that fit the definition and range of these applications.
-
product
Linear Regulators
It is designed to operate from a single input supply with an input voltage as low as 1.10 V without the requirement of an external bias supply to increase efficiency and provide up to 5 A of output current (IOUT).
-
product
PRECISION MAGNETICS ANALYZER
3260B SERIES
At the design stage of component development it is vitally important to understand how the component performs under different operating conditions. This might include operation at diverse frequencies, AC drive levels or DC bias currents.
-
product
Resistors
A passive two-terminal electrical component that implements electrical resistance as a circuit element. In electronic circuits, resistors are used to reduce current flow, adjust signal levels, to divide voltages, bias active elements, and terminate transmission lines, among other uses. High-power resistors that can dissipate many watts of electrical power as heat may be used as part of motor controls, in power distribution systems, or as test loads for generators. Fixed resistors have resistances that only change slightly with temperature, time or operating voltage. Variable resistors can be used to adjust circuit elements (such as a volume control or a lamp dimmer), or as sensing devices for heat, light, humidity, force, or chemical activity.
-
product
DC Bias Current Power Supply
TH1775
Shenzhen Chuangxin Instruments Co., Ltd.
TH1775 is a DC Bias Current Source (or DC Magnetization Current Source) used for inductance measurement of inductors and transformer windings with DC bias current. Except for constant current output, low additional error and wide frequency response range are important for bias current inductance measurement. High frequency LCR meter could be used, when the frequency response range is wide enough. MPU controlled auto current balance technology is adopted to realize AC+DC current overlap and constant current output from 0 to ±20A. Two TH1775 can be paralleled to supply a maximum current up to 40A.TH1775 permits high frequency measurement up to 1 MHz and can be directly controlled by TH2816A, TH2817A, TH2818 and TH2819. TH1773/TH1775 with its low additional error, wide frequency response range and sweep output function is widely used in DC biased inductance measurement. TH1775 also provides a perfect solution for magnetic material analysis.
-
product
RF Amplifiers Bias Controllers
RF amplifier bias controllers generate a regulated drain voltage and actively adjusts the gate voltage of an external amplifier to achieve constant bias current. It can be used to bias any enhancement and depletion type amplifier operating in Class-A regime with drain voltages (VDRAIN) as specified. These devices achieve excellent bias stability over supply, temperature and process variations, and eliminates the required calibration procedures used to prevent RF performance degradation due to such variations.
-
product
Passive Component ATS
Test and packing speeds from 80ppm to1,800ppmStandard functions - Inductance/quality factor test - Winding resistance test - Polarity testOptional functions - Layer short test - Insulation resistance test - Bias current testCircular vibrating plate design feeds inductors steadily and rapidlyIndex disc design eliminates dropped inductorsFour-wire measurement test socket designAutomatic discharge mechanism when feeding errors occurEach test station has an independent NG (No Good) product collection boxTest without packaging function provided, good products gathered in bulk collection boxExclusive data collection software designed for monitoring product quality in real timeReserved stations for number spraying and automatic optical inspectionSwitchable Chinese/English/Japanese operating interfaceEquipment is fast, stable and safe
-
product
SQUID Electronics
XXF-1
It is designed to satisfy the needs of nearly all low-Tc SQUID applications. Additional integrated current sources provide e.g. bias current and calibration pulses for TES applications. These current sources together with an additional switchable feedback path make two-stage SQUID operation very convenient.
-
product
Micro probes 1 MHz up to 1 GHz
MFA 02 set
The two in the set included micro probes are used to measure low-frequency magnetic fields up to 1 GHz, e.g. at signal conductors (150µm), SMD componets (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the BT 706 Bias tee. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee to a spectrum analyzer or an oscilloscope. The MFA 02 set delivery of Langer EMV-Technik GmbH includes correction lines. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.
-
product
DC BIAS CURRENT UNIT
3265B SERIES
To evaluate components at currents up to 125 A the 3265B DC Bias Units are used with either the Wayne Kerr 3255B series of Inductance Analyzers or the 3260B Precision Magnetics Analyzer. When one 3265B/25A or 3265BQ/25A DC Bias Unit is connected to an instrument up to 25 A of DC bias current can be set in steps of 25 mA with one unit. Additional DC Bias Units can be added such that with five units connected in parallel it is possible to set DC bias currents up to a maximum of 125 A DC.
-
product
PIN Diodes
PIN photodiodes convert light to current – without a bias voltage having to be applied. Silicon is commonly used as an inexpensive detector material in the Vis range. For higher demands, InGaAs is used; it covers the widest spectral range from the Vis to the NIR. We offer silicon carbide as a “solar-blind” detector specifically for the UV range.
-
product
SQUID Series Arrays
The SQUID series arrays are ideal for readout of TES sensors or as amplifier stage for discrete two-stage applications. Integrated bias resistors for TES or two-stage applications reduce wiring complexity. Various arrays with input inductances of 3 to 6 nH, input sensitivities of 17 to 23 µA/Phi0, and a current noise between 5 and 10 pA/sqrt(Hz) @ 4 K are available.
-
product
High Current Probes
*Low internal resistance to minimize arching*PogoPlus bias ball design*High current optimized base material and plating*Higher temperature spring design*Specialized high current tip geometry
-
product
Four Channel Low-Noise DC Bias Card
PI-41702
The PI-41702 is a four channel bipolar DC Bias supply that can provide an output current up to 100 mA per channel. The output voltage ranges from –8 V to +8 V, and this card has special filter circuitry to reduce the output noise for those applications that require a low noise bias output. Additionally there is a ‘D’ type connector that allows the introduction of laboratory type supplies to reduce the noise further. To change from using the internal power supplies to external power supplies requires repositioning jumpers. The PI-41702 also has voltage and current sense for remote measurement of the voltage and current levels.
-
product
External DC Bias Adapter
16200B
The 16200B test fixture is designed to operate with high frequency LCR meters and impedance analyzers. It allows you to supply a bias current across the device of up to 5 Adc through a 7 mm port by using an external DC current source.
-
product
High Output Current Op Amplifiers ≥ 100mA
Analog Devices high speed , high output current (≥100 mA) op amps deliver high output current while driving low impedance loads with excellent linearity. Whether it's high output current, low input bias current, wide bandwidth, high slew rate, or low distortion, no one sets more performance standards for next-generation designs with the widest portfolio of leading edge products than Analog Devices.
-
product
Operational Amplifiers
Operational amplifiers from ams are ideally suited to audio applications. These CMOS devices are available as single, quad or differential amps. They feature good common-mode rejection, have low input bias currents, good gain bandwidth, low total harmonic distortion and an excellent rail-to-rail output-drive capability of 200mA peak.
-
product
8-CH 24-Bit High-Resolution Dynamic Signal Acquisition Module
PCIe-9529
The ADLINK PCIe/PXIe-9529 is a high-performance, high density, 8-CH analog input dynamic signal acquisition module. The PCIe/PXIe-9529 features eight 24-bit simultaneously sampling analog input channels. The 24-bit sigma-delta ADC provides a sampling rate of 192 kS/s at high resolution, making it ideal for higher dynamic range signal measurement. All channels are sampled simultaneously and accept input range up to ±10V, and the analog inputs support software-selectable AC or DC coupling and 4 mA bias current for integrated electronic piezoelectric (IEPE) sensors. The module is especially designed to meet the requirements of vibration analysis and audio testing.
-
product
24-Bit High-Resolution Dynamic Signal Acquisition and Generation Module
PCI-9527L
The PCI-9527L is a high-performance, 2-CH analog input and 2-CH analog output dynamic signal acquisition board. This board is specifically designed for audio testing, acoustic measurement, and vibration analysis applications.The ADLINK PCI-9527L features two 24-bit simultaneous sampling analog input channels. The 24-bit sigma-delta ADC provides a sampling rate up to 216 KS/s at high resolutions, making it ideal for higher bandwidth dynamic signal measurements. The sampling rate can be adjusted by setting the onboard DDS clock source to an appropriate frequency. All channels are sampled simultaneously and accept an input range from ±40 V to ±0.316 V. The PCI-9527L analog input supports software selectable AC or DC coupling and 4 mA bias current for integrated electronic piezoelectric (IEPE) sensors.
-
product
Operational Amplifier
Op Amp Series
The amplifier is capable of operating at supply voltages from 0.9V to 3V with specified specs at 1V and 1.8V single supply.The input common mode range extends to both power supply rails without the offset glitch and input bias current phase reversal inherent to most rail to rail input amplifiers.
-
product
DC Current Bias Supply
DC1000A
To guarantee the quality and performance of inductive components such as inductors, chokes and transformers they are tested at their real-life operating point. If the inductor is designed to carry a DC current, then its inductance must be measured with that DC current present. Until now, these measurements were made by an LCR meter connected via special interfacing to a DC bias supply available only from the manufacturer of the LCR meter. The unique NEW DC1000A can be used with any precision LCR meter and connects simply into existing test fixturing.
-
product
Versatile quality control testing system
QuickSun® 550Ei
QuickSun 550Ei is a versatile testing system for qualifying of PV modules with dimensions up to 105 x 205 cm2. Basic set up includes a top class solar simulator which measures modules in sunny side up position enabling e.g. soiling simulations. Several additional measurement methods can be integrated to the same system including high resolution EL imaging with analysis software from one of the most recognized EL system suppliers. Also hot spot revealing IR images can be recorded by applying either forward or reverse bias current, and true nA scale leakage current measurements can be performed with sensitive enough instruments.
-
product
K-Band Waveguide Gunn Oscillator Module
FMWGN1001
FMWGN1001 is a K Band Waveguide Gunn Oscillator with a Center Frequency of 24.125 GHz and a Tuning Range of +/- 1.0 GHz. The unit has a Phase Noise @ 100kHz Offset of -95 dBc/Hz typ and Frequency Stability of -0.4 MHz/°C max. The Gun Oscillator has an Output Power of 10 dBm min and Power Stability of -0.04 dB/°C max. The Waveguide Gun Oscillator uses a Bias Voltage of 5.0 Volts and a Bias Current of 200 mA and has a Waveguide Size of WR-42 with a UG-595/U Flange.
-
product
Low Input Bias Current Amplifiers (<100 pA)
Low input bias current op amps are required whenever the difference of currents or voltage is small and needs to be measured accurately. These op amps are used so that the signal is not loaded down by the input of the op amps. Low input bias current op amps are critical for interfacing sensors in applications from photodiodes, pH meters, or other electrometer related functions to downstream electronics. Analog Devices has many precision op amps that fit the definition and range of these applications.
-
product
Micro probes 1 MHz up to 6 GHz
MFA 01 set
The micro probes are used to measure magnetic fields and they have a high resolution. They measure magnetic fields up to 6 GHz, e.g. at signal conductors (150µm), SMD components (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the Bias tee BT 706. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee BT 706 to a spectrum analyzer or an oscilloscope. Langer EMV-Technik GmbH includes correction lines in the delivery. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.
-
product
Bias Tees From 0.03 MHz To 85 GHz
Pulsar offers a large variety of bias tees that cover frequencies from DC to in both surface mount and connectorized packages. Many models are available with voltages up to 100 volts and currents up to 8 amps and custom requirements are welcomed. Options include higher voltage and current, higher RF input power and a choice of either an RF connector or a feedthrough connection for the DC input port.
-
product
O/E Converter
TIA-4000
The TIA-4000 is comprised of a fibre coupled InGaAs APD detector combined with a variable reverse bias voltage network and fast transimpedance amplifier. The output of the unit is brought out to a type K female SMA connector. Light falling on the detector generates a positive-going proportional current. This current, multiplied by the transimpedance produces a voltage that is proportional to the light incident on the detector surface.
-
product
Laser Diode Drivers
Arroyo Instruments offers a broad range of laser drivers to meet your exact test needs. From 100 milliamps to 100 Amps, all of Arroyo Instruments' LaserSource benchtop laser drivers include unique features not found on competing products such as optically isolated photodiode and modulation inputs, programmable PD bias, and both RS232 and USB computer interfaces. The LaserSource also has laser diode protection circuits such as interlock, ESD protection, and hardware limits for current and voltage.