Immunity
See Also: Immunity Test, Radiated Immunity, EMC
-
Product
Transient Immunity Tester
KES7700
-
Transient Immunity Tester KES7700 Series are transient surge tester that utilizes a compact unit system. A surge generator circuit is installed for each pulse unit as the tester meets the requirement of ISO7637-2, ISO7637-3, ISO16750-2, JASO D001, SAEJ1113, and other standards. The KES7700 Series meets a broad range of independent automobile manufacturer standards as well.
-
Product
Immunity
EFT coupling
-
s used for direct-contact measurements of impulse immunity in IC pins, according to IEC 62215-3 and IEC 61000-4-4.
-
Product
Immunity
ESD coupling
-
is used for conducted coupling of Langer ESD pulses (200ps rise time) into ICs.
-
Product
Immunity DC
PGA 1240
-
The power generator PGA 1240 is suitable for EMC testing in accordance with standard IEC / EN 61000-4-16 in the frequency range from DC to 300 kHz.
-
Product
Impulse Magnetic Field Immunity Tester
IMF61000-9
-
IMF61000-9 impulse magnetic field immunity tester is high performance test instrument which special designed for to do impulse magnetic field immunity test and fully meet IEC61000-4-9, EN61000-4-9 and GB/T17626.9 standards, also it come with high intelligent, high stable performance and easy operation characteristics.
-
Product
Electromagnetic Immunity Scanner
SmartScan 350
-
Reproducing similar soft or hard failure to the gun test - Flexible automatic failure detection module - Susceptibility map generation- Automatic report generation- Flexible scan area editor (SAE)- Flexible display (3D, histogram)- Matlab support- Expandability (EMI scan, phase measurement, NFFF transformation)- Custom design probes
-
Product
Conducted Immunity Test System
-
Conducted RF immunity tests acc. to IEC/EN61000-4-6 and BCI tests acc. to ISO 11452-4 and MIL-STD 461 CS 114 Signal generator,RF-power amplifier, RF-power meter and directional coupler (optional) in one 19”-caseStand-alone operation possible with optional available netbookControl-software includedMost important parameters are shown on an integrated displayAutomatic EUT-monitoringOperation via USB port of a PC or NotebookComplete range of CDNs available
-
Product
Multifunctional Immunity Test System For Automotive Electronics
EMS-ISO7637
-
EMS-ISO7637 automotive multifunctional immunity test system meet newest ISO7637-2 requirement of
. This standard was issued by international organization for standardization, and this system included all of ISO-7637 required test waveform and meet most of automotive manufacturer’s requirement for automotive electronic immunity test. -
Product
Coupling Decoupling Network for Conducted Common Mode Immunity Testing According to IEC 61000-4-6
CDN
-
The CDN M5 is intended to inject common mode disturbance signals to power supply of mains lines (unscreened) in the frequency range from 150KHz to 230MHz. A variety of calibration adapters and other accessories are available as an option. RF Standard connector: BNC type, AC socket 4mm safety bananas.
-
Product
Damped Oscillatory Magnetic Field Immunity Tester
DOMF61000-10
-
DOMF61000-10 damped oscillatory magnetic field immunity test system included damped oscillating wave generator and single ring coil, it’s designed for to do damping oscillation magnetic field immunity test and fully meet IEC 61000-4-10, EN61000-4-10 and GB/T 17626.10 standards requirement.
-
Product
Immunity
RF coupling
-
is used for the conducted measurement of the immunity according to IEC 62132-4.
-
Product
Software for Immunity Test METES-EMS series
-
METES-EMS is software for Automated Test Solution to meed Immunity Std. each for Keys : Support for latest Windows OS Access via USB/LAN interface to measurement equipments to achieve
-
Product
RF Conducted Immunity Test System
RFCI61000-4-6
-
RFCI61000-4-6 RF Conducted Immunity Test System is an automatic test system which is for the conduction sensitivity testing, it is fully meets IEC61000-4-6.2006, ISO11452-4, GB/T17626.6-2008 and GTB152B-CS114 etc standards. RFCI61000-4-6 internal source and broadband power amplifier can be generated 3 voltage test levels: 1v, 3v and 10v, and has the function of the real detect output level. It has two operation software which is calibration software and test software. When measuring, the signal is in 1 KHZ sine wave amplitude modulation system (80%) to simulate the actual harassment, and can through the coupling/decoupling network (CDN or electromagnetic clamp) to make the harassment signal coupled to the device.
-
Product
15W to 60W - Single Output / Multiple Output
DPX Series
-
*Single, Dual and Triple Outputs*9.5-36 Vdc, 18-75 Vdc Inputs*Meets EN55022 Class B*1600 Vdc Isolation*-40 up to 95 °C Operating Temperature*EN61000-4 Immunity*Narrow 24.5 mm width
-
Product
Radiated Immunity Test System
-
Beijing KeHuan Century EMC Technology Co,.LTD
Radiation Immunity Test System.
-
Product
EMC Testing Knowledge & Equipment
-
Creating, delivering, installing, and training on EMC test systems; RF Immunity systems, RF Radiated and Conducted Emissions systems, Conducted Immunity and Pre-compliant EMC systems.
-
Product
EOS Tester
KT-200SG
-
This test instrument stands for the EMI(Electro Magnetic Immunity) ability test to the electric devices, electronic circuit boards & electric equipments. Recently this instrument is widly used in many companies in Korea & other countries to test the immunity to thier products-power supply, drive PCBs, communication systems, LCD display panels whether they are safe or not against the impulse & noise.All for the purpose, of this object, it generates 4 ~ 5 kinds of different impulse test waveforms.Output test voltage level : 5 ~ 200 V ImpulseOutput voltage polarity : Positive, NegativeType of waveforms
-
Product
14W to 60W - Single Output
ZPSA Series
-
*Wide Range AC Input*Low Profile, Industry Standard Footprint*Global Safety Agency Compliance*EN61000-4 Immunity
-
Product
15W - Single Output / Multiple Output
PXB Series
-
*Industry Standard 1" x 1" Footprint*9-18, 9-36, 18-36, 18-75, 36-75 Vdc Inputs*3.3, 5, 12, 15, ±5, ±12, ±15 Vdc Outputs*1600 Vdc Isolation*-40 to 100 °C Case Temperature*Six-sided Shielding*EN61000-4 Immunity
-
Product
IEC61000-4-4 4.8KV Electrical Fast Transient Immunity Generator
EFT-404BX
-
Shenzhen Chuangxin Instruments Co., Ltd.
EFT-404BX Impulse Generator is fully met requirements of the standards IEC61000-4-4 and GB/T17616.4.
-
Product
EMC Testing Services
-
Our sophisticated technology can meet the diversified needs of customers. Component Tests: Immunity, Radiated Immunity, ALSE, TEM cell, Bulk Current Injection, Stripline, Conducted Immunity, Transient Immunity, Power Supply Variations, Electrostatic Discharge Emissions, Radiated Emissions, Conducted Emissions, Transient Emissions. Vehicle Tests - Radiated Immunity, Radiated Emissions.
-
Product
Immunity Development System
-
Used for EMI suppression in printed circuit boards during the development phase. The developer can use the E1 set to quickly identify the causes of burst and ESD interference. This allows the developer to design suitable measures to solve the causes of the interference. It can also be used to test the effectiveness of the measures taken.
-
Product
Semiconductor Products
-
International Testware Corporation
International Testware supports all major ATE models for today's semiconductor products.CredenceAdvantestCaesarHewlett-PackardLTXIMSSchlumbergerAndo...and MANY moreTeradyneMosaidOur Solutions offer:Mixed-SignalEMI ReductionR/FCustom TailoredLow NoiseReliable PerformancePrecise Length MatchingSuperior Impedance ControlCrosstalk "Immunity"Minimal Inductance
-
Product
Bulk Current Monitoring Probe
MP-50
-
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.
-
Product
Immunity Testing Systems
CIS Series
-
The CIS series test systems are configured to perform conducted immunity testing according to IEC 61000-4-6. The system includes an ACS series power amplifier, coupling/decoupling Network (CDN), directional coupler, 150Ω to 50Ω adapters, power attenuators, cables and [optional] CSAT software. These systems, when properly configured, are capable of testing your products to all levels given in IEC 61000-4-6 up to 230 MHz. You can choose from three systems. Follow the links below for detailed information, including a comprehensive datasheet listing system specs.
-
Product
Anechoic Chamber
EMC-3
-
A 3 meter test range ensuring fully compliant Emission and Immunity testing. Ferrite and hybrid pyramidal absorbers are combined in a unique pattern within a SmartShield high performance chamber. Operating at a 3m test distance, this chamber is compliant to CISPR-16 with a measurement zone diameter of 1-2 meters.
-
Product
RF swept immunity package
EMiSweep
-
This is a flexible Windows immunity package which provides the utilmate flexible Graphical User interface. Other visual aids provides a swept as well as spot frequency assessment.
-
Product
EMC Testing
-
D.L.S. Electronic Systems, Inc
EMC testing and consulting services to the Electronics, Medical Equipment, Automotive, Aerospace, Computer, Telecommunications, and other industries. We are a NVLAP certified test facility, capable of testing electronic equipment to today's high frequency requirements. Our 14 Test chambers and 3 Open Area Test Sites can perform full scan Immunity and Emission testing at frequencies up to 40 GHz. Please contact us for your specific requirements.
-
Product
Anechoic Chamber room for Automotive components
-
Anechoic Chamber room of most suitable Automotive devices EMI/EMS test of the method of ALSE, which meet the global standard like a 2004/104/EC, several emmission standard like a CISPR25 which automotive manufacturers in EU/USA refer to, Immunity standard like a ISO11452 and others for the Automotive devices.
-
Product
EMI EMC test Solutions for Immunity
-
Scientific Mes-Technik Private Ltd
EMI EMC test Solutions for Immunity