Harmonic
Sinusoidal component of a perodic wave or for a sine wave, it is an integral multiple frequency of the wave.
-
product
Network Analyzers
MPR2 Series
Dimensions:DIN4 kVArh, Max, Min: available (available)% THD I: none (none) % THD V: none (none)Harmonics 1-51.: RS-485: none (none)Digital Input:Digital Output:Temperature Input:AOV:RLY: Memory:Current Voltage Unbalances: none (none) X5/X1: none (none)Plug & Meter: available (available) 85-300 VAC/DC: available (available)
-
product
RF/Microwave Test Capability
Teledyne Labtech have extensive microwave alignment and microwave testing facilities. This includes the ability to test noise figure, S-parameters and harmonics. This ensures that Teledyne Labtech can supply a fully compliant product and provide a complete turnkey microwave assembly and test solution.
-
product
Microprocessor Multifunction TRMS Power Meter + Harmonics Analyzer
8100 C
Kusam Electrical Industries Limited
INPUT :• Input Voltage Range :Voltage: 55 ~ 300V AC, or 300 ~ 600V AC, 45 ~ 65Hz.P.T. Ratio Programmable upto 9999 / KV.• Input Voltage Over Range :Voltage : 200 % Continuous, 300 % of rating for 10 sec.• Input Current Range :Current : 110 % of rating. 0-1A or 0 - 5AC.T. Ratio programmable upto 9999 / 5A.Input Current Over Range:Current : 400 % Continuous, 2000 % of rating for 10 Sec.• Input Frequency : 45 Hz ~ 70 Hz.• Input Burden :Voltage 0.25 VA / Unit, Current 0.25VA / Unit, at 50 / 60HzOUTPUTDC Current: 0 20 m A DCLoad resistance drive: output drive 10 V DC maximum.DC Voltage: 0 -10 V DCLoad resistance drive: output drive 5mA maximumOutput Protection: No damage even if output is Open or Short Circuit.Output Response Time : £ 1 Sec.Digital Output : RS485 Output, Isolate Type with MODBUS RTU mode., 4800, 9600,19200Baud Rate, User Selectable.
-
product
RF Front-end
The RF integrated passive device (RF IPD) uses a high-resistivity substrate to integrate quality factor components such as capacitors and indictors. Many functions like impedance matching networks, harmonic filters, couplers, baluns, and power combiners/splitters can be designed using IPD technology. ST's IPDs are manufactured using thick film and HiRes Si or glass wafer manufacturing technology and photolithography processing.
-
product
HID Ballast Tester
WT2000-HID
• Input Parameters Measurement: 1) Test voltage, current, power, power factor, power line frequency, total harmonic and 0~50 harmonic 2) Range of voltage and current basic wave frequency: 45Hz~65Hz 3) Range of narrow frequency: 45Hz~5kHz 4) Range of wide frequency: 45Hz~1MHz
-
product
CCFL Ballast Tester
WT2000A-CCFL
This tester is specially designed for analyzing the electrical characteristics of CCFL Electronic Ballast, meets the test requirements in international standard• Input characteristics analysis: measure Vrms, Irms, W, PF, Hz, phase angle Measure THD, 0 to 39th harmonic components, Accuracy: ±(0.4% reading+0.1% range+1 digit)• Output characteristics analysis: measure lamp voltage, lamp current, lamp power, oscillatory frequency, crest factor of lamp current, Accuracy: Class 2• Interface RS-232C provided for easier communication with PC for printing test report
-
product
Differential And I/Q Device Measurements
S95089B
The S95089B combines source-phase control of multiple internal or external sources with frequency-offset mode, enabling simplified test of I/Q modulators/converters, differential mixers, and harmonics or amplifiers.
-
product
Adjustable High Frequency Reference Ballast
HCS-109A
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
product
Waveguide Harmonic Mixer, 75 to 110 GHz
11970W
The 11970W extends the frequency range of the Keysight N9030A PXA high-performance signal analyzer to the W-band (75 to 110 GHz). It is also fully compatible with other Keysight spectrum analyzers including: the E4440A/46A/48A PSA (with Option AYZ), the E4407B ESA-E (with Option AYZ), the 856xEC, the 8566B (with a preamplifier), and the 7000 modular analyzer (with the 70907A/B external mixer interface module).
-
product
Multi-Channel Digital Power Meters
66203/66204
Chroma Systems Solutions, Inc.
Voltage Range :15/30/60/150/300/600 VrmsCurrent Range :0.005/0.02/0.05/0.2/0.5/2/5/20 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bits Analog/Digital convertersHalf rack size, 4 input modules design (66204)Support different wiring configuration power measurement (1P2W/1P3W/3P3W/3P4W)Support external shunt and CT for higher current measurement application5 mA minimum current range & 0.1mW power resolutionMeets ENERGY STAR / IEC 62301 /ErP measurement requirementsAccumulated energy methods for unstable power measurementUser-define criteria provides automatic PASS/FAIL indicationsDual current shunt design provides high accuracy over a wide current rangeTHD and user-specify order distortion measurementInrush current and energy measurementVoltage/ Current harmonics measurement up to 50 orders
-
product
Operational Amplifiers
Operational amplifiers from ams are ideally suited to audio applications. These CMOS devices are available as single, quad or differential amps. They feature good common-mode rejection, have low input bias currents, good gain bandwidth, low total harmonic distortion and an excellent rail-to-rail output-drive capability of 200mA peak.
-
product
AC Power Source
SPS-100
Kongter Test & Measurement Co., Limited
SPS-100 is designed for various tests of analog and digital AC Voltage meter and Current meter, Single/three phase active and reactive power meter, Phase angle meter, Single/three phase power factor meter, frequency meter, and synchronous-meter, Single/three phase active and reactive power meter; it also outputs 2nd ~63rd harmonics.
-
product
Modulators / Demodulators
Mini-Circuits QPSK Modulator and I/Q Modulator / Demodulators are available in connectorized or surface mount packages up to 2000 MHz. These components provide excellent harmonic suppression as well as good carrier and sideband rejection while maintaining low conversion loss over the operating frequency band.
-
product
RF/Microwave Test Capability
Teledyne Labtech have extensive microwave alignment and microwave testing facilities. This includes the ability to test noise figure, S-parameters and harmonics. This ensures that Teledyne Labtech can supply a fully compliant product and provide a complete turnkey microwave assembly and test solution.
-
product
Power Capacitors with Protection Filter
CPFVF / CPMVF
Lifasa - International Capacitors, SA
The capacitors of the CPFVF and CPMVF series are formed by a power capacitor, an antiarmonic protection reactance and fuse or magnetothermic protection. These capacitors are specially designed for the fixed compensation of transformers in networks with a high level of harmonics.
-
product
Fuel Flow and Torque Converter
Model 44SM1
This self-contained, remotely mountable Second Harmonic Fuel Flow Interface accepts data from a second harmonic fuel flow transmitter then converts this information into a frequency output proportional to fuel flow. In addition, this module will accept signals from a T56 Torque Tranducer and provide a DC voltage proportional to Torque. Typical application is for use with Flight Management and Nav Management Systems. The use of field proven designs and carefully selected components assures high reliability field performance.
-
product
Three-Phase AC Power Source 320 Vrms, 6 KVA, 550 Hz
AC6906L
Keysight’s AC6900 Series three-phase power sources provide a complete AC and DC power solution by combining the capabilities of a multimeter, harmonic analyzer, and power analyzer in one instrument.
-
product
SHG Spectrometer
Second harmonic generation (SHG) is an effective technique for surface probing. By SHG, monolayer adsorbtion can be detected. With different input/output beam polarizations SHG can yield information on the average orientation of molecular adsorbates.
-
product
20KVA to 200KVA Industrial UPS (3Ø – 3Ø)
NSP Series 20KVA to 200KVA
- Designed for powering critical Industrial and IT systems- DSP controlled IGBT based PWM technology- Design topology enables N+1 parallel redundancy- Industrial grade high speed CAN bus communication- User Friendly Matrix LCD and LED mimic front control and digital monitoring- Fully rated make before break maintenance bypass operation- Optional break-less load transfer via static switch- Low harmonic distortion- High crest factor tolerance and dynamic stability- Lower TCO- Continuous full rated power at ambient as high as 45°C- N+1 Parallel operation of UPS without any common hardware- Advanced Communication Capability (RS485/Modbus/SNMP)- High branch fuse clearing capacity- On-line battery bank test without load disconnection- Compact, elegant, and light weight enclosure- Easy installation with wheels for maneuverability and front bottom terminals
-
product
Product Safety Testing
NCEE Labs is an A2LA Accredited product safety compliance testing lab. We specialize in compliance testing to US and harmonized international standards. NCEE Labs also offers NRTL testing services. With experienced product safety engineers, we provide expert assistance, whether evaluating early prototypes or assisting with aftermarket design changes.
-
product
UX Range Broadband Power Amplifiers 2 GHZ - 6 GHZ
UX Series
Class A solid stateBroadband (instantaneous single band): 2 GHz 6 GHzTypical output power : 15 W CWLinear output power (1 dB compression) guaranted with harmonics <-20dBc:P1dB > 12 W and H < -20 dBc up to 4 GHz andP1dB > 11 W and H < -20 dBc from 4 GHz to 6 GHzAir cooling: self contained fansCan operate in full mismatch conditions without damageUpgradable to UX 30 possible (4U)Reliable, efficient and robust19" Rack3 years standard warranty
-
product
Three-Path Diode
NRPxxS/SN/SN-V
The R&S®NRPxxS/SN power sensors use three separate diode paths, each operated in the optimum detector range. As a result, the average power can be determined with high accuracy independent of the modulation type. Measurement results are hardly affected by interfering signals or harmonics.
-
product
PXI-2798, 40 GHz, Dual-Transfer PXI Transfer Switch Module
782358-01
40 GHz, Dual-Transfer PXI Transfer Switch Module—The PXI‑2798 can route RF or microwave signals in automated test applications. Designed to operate with less than 1 dB insertion loss at up to 40 GHz, the PXI‑2798 appears almost invisible to signals at much lower frequencies as well. You can use this module for basic signal routing or inserting and removing components in a signal path. The PXI‑2798 is also well-suited for passing high-order harmonics from RF upconverters or routing multiple sources to RF downconverters.
-
product
Phase Noise Measurement Up To 70 GHz
S930317B
S930317B enables phase noise measurements using a PNA or PNA-X vector network analyzer. Simplify your measurement workflow by measuring phase noise on the same connection as your network analysis measurement of 2-port active devices up to 70 GHz, without needing to connect a spectrum analyzer or harmonic mixer.
-
product
9kHz to 20/40GHz Signal Generator
CSG Series
Corech Microwave’s CSG series of Compact Microwave Signal Generators(Signal Source)operate from 9kHz to 20GHz / 40GHz. It offers high dynamic output power -120 to +17dBm, ultra low phase noise: -105dBc/Hz@10KHz, low harmonics and spurious. These exceptional performances make CSG9K20GA / CSG9K40GA an ideal choice for many test and measurement applications, including Semiconductor, Quantum Technology, Radar and Communication etc.
-
product
Power Analyzers & Wattmeters
Measurements International Ltd.
Direct Replacement for 2010A Wattmeter in the AccuLoss® Loss Measurement Systems, Basic Power Accuracy < 0.005 %, 10 Current Ranges, 2 Voltage Ranges, Line-and-Line and Line-to-Ground Voltage Measurements, Full Power Factor Range, Complete Waveform Analysis, Total Harmonic Distortion Analysis, Phasor Analytical Representation.
-
product
AC Power Sources
CSW Series
AMETEK Programmable Power, Inc.
The CSW Series represents a new generation of AC/DC power sources that address the increasing demands on test equipment to perform additional functions at a lower cost. By combining a flexible AC/DC power source with a high performance power analyzer, the Compact CSW Series is capable of handling complex applications that have traditionally required multiple systems. The sleek integrated approach of the CSW avoids cable clutter that is commonly found in test systems. All connections are made internally and the need for digital multimeters, power harmonics analyzers, and current shunts or clamps is eliminated.
-
product
NI-9242, 250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module
783107-01
250 Vrms L-N, 400 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9242 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, standard potential transformers, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9242 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta.
-
product
Digital Harmonics Clamp Tester
HWT-301
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Harmonics and leakage current measurements.*Up to 25th harmonics current and voltage measurements.*True rms reading for ACA and ACV.*Data-hold and Auto power off function.*Conform to IEC safety requirements.
-
product
Source of Signals
CRS+
The CRS+ is a stable and calibrated source of signals which cover the 9KHz - 30MHz frequency range. The fundamental signal is a 15KHz comb and each harmonic is output as a narrowband peak of known amplitude. This signal is output on either the L and N lines, referenced to ground. A switch provides on/off and line selection.