Working Standards
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2H
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Standard Method Compliant
Shimadzu System GC Analyzers are built and tested to meet the specific analysis requirements of applicable industry standards.
-
product
Primary VoltageE Standard: Cryocooler (Closed- Cycle Refridgerator) System
The Hypres Primary Voltage Standard System with cryocooler (closed-cycle refrigerator) is a complete, computer controlled system implementing a variety of voltage calibration functions. This system configuration is a cryogen-free complete Primary Voltage Standard System with parameters that are identical to the liquid helium version.
-
product
Standard Pitch Spring Probes
Other than spring probes with gold plating, we have spring probe with anti-solder migration coating and plating that were developed by KITA. We also have anti-solder migration material for plunger tip. These are all included in “MARATHON” series. They have wide range of tip type for various use for every popular total length.
-
product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1L
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-4V1S
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
product
Standard Gain Horns
26 dB typical gain at center frequency. Aluminium made High performance Standard Gain Horn. From 75 GHz up to 500 GHzUG-387 U/M flange. Specific gain values can be requested. We offer two Standard Gain Horn product lines that go from 75 GHz up to 500 GHz, one with high performances for the most demanding of lab applications and the other with reduced prices and sufficient quality for the majority of SGH applications. Anteral makes sure that each client can have the best SGH for their particular needs.
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T24-4-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Cold-Atom Frequency Standard
Rack-mount microwave atomic clock using laser-cooled 87Rb atoms. Production unit target specifications: Allan deviation 2×10-12 @ 1 s, 2×10-14 @ 104 s; flicker floor 1×10-14; absolute accuracy < 1×10-13.
-
product
Standard Ratio Box For Calibration
ST-105
The ST-105 is a calibration box with standard ratios. It is used for calibration of any turn ratios measurement system. Housed in a rugged, waterproof case, it is very lightweight.
-
product
Standard 1.32 (37.40) - 4.50 (128.00) Battery Probe
CP-2SB-6
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 69Full Travel (mm): 1.75Recommended Travel (mil): 59Recommended Travel (mm): 1.50Overall Length (mil): 236Overall Length (mm): 6.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
Standard 1.32 (37.40) - 4.50 (128.00) Battery Probe
CP-2TB-6
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 69Full Travel (mm): 1.75Recommended Travel (mil): 59Recommended Travel (mm): 1.50Overall Length (mil): 236Overall Length (mm): 6.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
Rubidium Standard with Optional DDS Signal Generator
1450B
The 1450B outputs can be configured as sine waves or square waves and can provide frequencies of 10MHz, 1MHz, 100kHz, 1pps or optional signal generator outputs. The signal generator outputs use direct digital synthesizer (DDS) technology and are confirurable from 100Hz to 171MHz. The 1450B also includes a 1pps input that can be used to discipline and automatically calibrate the 1450B. The 1pps input signal is typically obtained from an external device like a GPS frequency receiver/antenna. The Novatech GPS1 Smart Antenna with 1pps output is available as an accessory to provide a complete turnkey solution.
-
product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-F
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-2V1S
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1V-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2X
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3C
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.95 (26.90) - 4.50 (128.00) Battery Probe
CP-2SB-12
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 128Full Travel (mm): 3.25Recommended Travel (mil): 118.1Recommended Travel (mm): 3.00Overall Length (mil): 472Overall Length (mm): 12.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
product
Standard 0.39 (11.00) - 1.39 (39.00) Replaceable General Purpose Probe
MEP-30G
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 30Test Center (mm): 0.76Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 690Overall Length (mm): 17.53
-
product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25F-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
product
Standard Round 2m Cables, Shielded, for Higher Current
ST010-S
Connection to digital boards, intended for higher currents. to be used with CPCI-1500, APCI-1500, APCI-1564, APCI-2032.
-
product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-C
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
product
Standard Type Spring Probes
From for bare board to for ICT, we have variety of spring probes for PCB. In addition to variety of tip type and total length, we also have receptacles that match the best to spring probes. We can also attach lead wire to the receptacles.
-
product
Standard - 1.44 (41.00) - 4.50 (128.00) High Current Probe
HCP-13A
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1T1-4
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I15-4
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50L-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00