Mirrors
-
Product
Modular Mounts
M-SWITCH
-
The M-Switch series of adjustable, modular mounts are designed to redirect a horizontal interferometric set-up to a vertical one. This vertical orientation can help reduce distortion effects commonly found from clamping, and reduce alignment time. There are 4 primary versions of hardware designed to enable testing of mirrors, windows, lenses and lens assemblies. Holding of the part under test can be done with a variable 3 arm mount (for flexibility) or our kinematic mount (for high volume). Reference mirrors can be supplied with a variety of flatness and coating specifications to match your application needs.
-
Product
Optomechanical Devices
-
Optomechanical devices include an optical chopper, scanning galvo mirrors, adaptive optics, a motorized pinhole wheel, a piezo objective scanner, a motorized flip mount, motorized filter wheels, and optical beam shutters.
-
Product
Confocal FLIM for Macroscopic Objects
DCS-120 Macro
-
*FLIM of Macroscopic Objects*Scan Field Up to 15 mm Diameter*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Scanning by Fast Galvanometer Mirrors*Channel Seperation by Dichroic or Polarising Beamsplitters*Individually Selectable Pinholes and Filters*One or Two BDL-SMN or BDS-SM ps Diode Lasers*Tuneable Excitation by Super-Continuum Laser with AOTF*Two Fully Parallel Detection Channels*Two HPM-100-40 GaAsP Hybrid Detectors*Optional: Two HPM-100-06 Hybrid Detectors, IRF Width < 20 ps FWHM*Optional: HPM-100-50 Hybrid Detectors for NIR FLIM*Optional: Multi-Wavelength FLIM*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Simultaneous FLIM/PLIM*Wideband Version, Compatible with Tuneable Lasers*Electronic Pinhole Alignment*Optional: Spatial Mosaic FLIM via Motorized Sample Stage
-
Product
Solar Simulation Systems
-
PET Solar Simulators consist of a Light Source with a built-in Lamp Power Supply. The Solar Simulator has an ellipsoidal reflector that surrounds the lamp and collects most of the lamp output. The radiation from the lamp is focused onto an optical integrator that helps produce a uniform diverging beam. The beam is diverted 90° by a mirror onto a collimating lens. Special filters are placed between the mirror and the collimating lens to shape the radiation spectra to match various air masses. The output is a uniform beam that closely matches the sun's radiation spectra for a given air mass. Various models offer different areas of illumination. Each model can be manufactured to simulate the sun's radiation for different air masses.
-
Product
Deformable Mirrors
-
High-precision adaptive optics components designed to correct wavefront aberrations in real-time for imaging, microscopy, ophthalmology, and laser beam shaping.
-
Product
Differential Interferometer
10715A
-
The Keysight 10715A Differential Interferometer performs differential measurements between the supplied reference mirror and a measurement plane mirror. It provides exceptional long term stability. The 10715A minimizes dead path, and, because the entire optical path through the interferometer is common mode, it eliminates thermal drift in measurements. The resolution of the measurement is twice that of a linear or single-beam interferometer.
-
Product
Multiphoton FLIM System
DCS-120 MP
-
*Multiphoton FLIM Upgrade for Existing Conventional Microscope*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Scanning by Fast Galvanometer Mirrors*Channel Seperation by Dichroic or Polarising Beamsplitters*Individually Selectable Pinholes and Filters*Excitation by Ti:Sa Laser*Two Non-Descanned Detection Channels*Two HPM-100-40 GaAsP Hybrid Detectors*Optional: Two HPM-100-06 Hybrid Detectors, IRF Width < 20 ps FWHM*Optional: HPM-100-50 Hybrid Detectors for NIR FLIM*Optional: Multi-Wavelength FLIM*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Simultaneous FLIM/PLIM*Electronic Pinhole Alignment*Z-Stack FLIM Acquisition with Zeiss Axio Observer Z1*Optional: Spatial Mosaic FLIM via Motorized Sample Stage*Laser Control via SPCM Software
-
Product
Measurement Of Straightness, Flatness, Positioning Uncertainty Of Round Tables
RTM - Measurement Of Positioning Uncertainty Of Indexing Tables
-
Optik Elektronik Gerätetechnik GmbH
RTM is a software for the measurement of positioning uncertainty of indexing tables using an electronic autocollimator and a polygon mirror as angle reference.
-
Product
Optical Switches
-
This latest technology platform presents the best value in terms of size, form factor, durability, and cost. The design of our MEMS optical switch centers on DiCon's proprietary dual-axes tilting MEMS mirror and is expandable up to a 1x36 switch configuration. Large fan-out 1xN optical switches and non-blocking fan-out/fan-in NxM matrix optical switches are built by cascading multiple of these 1xN switches. The MEMS 1xN fiber optic switch passes the stringent Telcordia GR-1221 qualification and is vastly deployed in today’s optical communication networks. With a lifetime of over a billion cycles, the durability of this MEMS device makes it a perfect choice for optical network monitoring applications that require frequent switching.
-
Product
Small Geological Compass
COSTU
-
F. W. Breithaupt & Sohn GmbH & Co.KG
*Rugged high-quality pressure-cast housing*Tracing edge with 110mm graduation*Mirror of chromed brass with sighting slotF*ront to rear sight 110mm*Liquid damping of magnetic needle*Graduation: 360° in 5° steps*Inversed pendulum clinometer with ±90° graduation to measure fall angles*Circular level (1°/2mm)
-
Product
One Axis Differential Interferometer
10719A
-
The Keysight 10719A One Axis Differential Interferometer makes either a differential linear or angular measurement for use in single and multiple axis applications. The linear measurement gauges the displacement between two objects, such as a stage and an optical column or inspection tool. The 10719A also measures either pitch or roll. An angle is measured when both reference and measurement beams measure to the same mirror. The 10721A provides high immunity to unwanted interferometer displacement, such as thermal expansion. It is a modular, compact design with monolithic optics for maximized mechanical stability. Use of a small 3 mm beam helps decrease Abb offset error.
-
Product
Video Borescope
Hawkeye® V2 Deluxe
-
The Hawkeye® V2 Deluxe Videoscope Kit contains a bright, high-resolution, and durable camera that delivers sharp, clear photos and videos in a wide range of demanding inspection applications. The large 5″ LCD screen provides detailed close-up views, includes a 2x zoom functions, mirror image capability, and easy-to-use intuitive controls. This allows teams to quickly and easily inspect difficult and hard-to-reach areas.
-
Product
PXI Dual 2 Channel (M Mode) SC 62.5 Cons
40-855-222-M62.5
Switch Module
The fiber optic switches connect the common to a channelby redirecting the optical signal into a selected output fiber.This is achieved using Micro-Mechanical Mirrors driven bya highly precise mechanism and activated via an electricalcontrol signal.
-
Product
Slip Line Detection System
YIS 200
-
The YIS and SF Series metrology systems are designed for optical detection of wafer defects such as crystaldislocations, slip and other defects. The YIS-300HM (for 300 mm wafers) and YIS-200HM (for 200 mm wafers) utilizeMakyoh optics technology (Magic Mirror) and integrated robotic wafer handler provided by Hologenix.
-
Product
High-Stability Adapter
10723A
-
The Keysight 10723A high-stability adapter converts the 10706A Plane Mirror Interferometer into an 10706B High-Stability Plane Mirror Interferometer. The 10706B is a thermally-stable optic with measurement drift reduced to approximately 1/12 the value achieved by conventional plane mirror interferometers.
-
Product
Optical Square
10777A
Accessory Kit
The Keysight 10777A Optical Square, used with Keysight straightness measurement optics, adds squareness measurement capability to the Keysight5530 Laser Calibration System. The optical square measures the squareness of axes during laser calibration of a machine tool. The Keysight 10777A uses two accurately-aligned mirrors to direct an output beam at precisely 90 degrees to an input beam.
-
Product
High-Resolution Interferometer
10716A
-
The Keysight 10716A High Resolution Interferometer is used for single and multiple axis applications such as precision X-Y stages. The 10716A offers twice the resolution of conventional plane mirror interferometers and has the same excellent thermal stability as the 10706B High Stability Plane Mirror Interferometer. Measurement drift is typically of that exhibited by a conventional plane mirror interferometer. These features result in improved accuracy, repeatability, and thermal stability. However, slew rate is halved.
-
Product
LXI Optical Switching - 1:1 Multiplexer (SPST) Plugin Module
65-281-380
Multiplexer Module
The 65-281-380 1:1 multiplexer is part of the 65-280 and 65-281 ranges of optical plug-in modules offering matrix & insert/bypass or multiplexer & SPST topologies respectively with all models based on MEMS fiber optic switches and available in various populations per plugin. In addition, a choice of different connector styles to suit most applications is offered: FC/APC (for optimal performance), FC/PC, SC/PC and ST for general applications and LC for high density applications. They use MEMS (Micro-Electro-Mechanical-Systems) based optical switches to route signals between terminals by redirecting the optical signal. This is achieved using micromechanical mirrors driven by a highly precise mechanism activated via an electrical control signal.
-
Product
LXI Optical Switching - 5x5 Matrix Plugin Module
65-280-322
Matrix Switch Module
The 65-280-322 5x5 matrix is part of the 65-280 and 65-281 ranges of optical plug-in modules offering matrix & insert/bypass or multiplexer & SPST topologies respectively with all models based on MEMS fiber optic switches and available in various populations per plugin. In addition, a choice of different connector styles to suit most applications is offered: FC/APC (for optimal performance), FC/PC, SC/PC and ST for general applications and LC for high density applications. They use MEMS (Micro-Electro-Mechanical-Systems) based optical switches to route signals between terminals by redirecting the optical signal. This is achieved using micromechanical mirrors driven by a highly precise mechanism activated via an electrical control signal.
-
Product
Micro-spot DUV Spectroscopic Reflectometry
FilmTek 2000 PAR
-
Scientific Computing International
A low-cost solution for high-throughput, fully-automated mapping of patterned wafers for development and production environments. Utilizes patented parabolic mirror technology to measure wavelengths from DUV to NIR with a spot size as small as 13µm. Fully user-customizable wafer mapping capabilities rapidly generate 2D and 3D data maps of any measured parameter.
-
Product
Current Mirrors
-
Analog Devices current mirrors are precision, high dynamic range, wide variable supply parts used for optical power monitoring, voltage biasing with current monitoring, and voltage-to-current conversion. Our current mirrors can monitor current down to as little as 3 nA and as much as 3 mA, with a linearity of 1% or better. The current dynamic range is 120 dB or 6 decades of current range, while the overcurrent protection feature in our devices forces the input pin to ground to avoid part damage. Over temperature (–40°C to +85°C) and process, the dynamic range only suffers 10 dB at the lower end of the range.
-
Product
Gas Filter Correlation CO Analyzer
Model T300U
-
Teledyne Advanced Pollution Instrumentation
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance analyzer.The optical bench is enclosed in a temperature controlled oven, dramatically decreasing instrument noise and drift. The objective and field mirrors in the sample cell are gold plated to maximize signal to noise performance, while a temperature-controlled Nafion dryer on the inlet minimizes water interference caused by ambient humidity changes. Periodically, the T300U seamlessly corrects its baseline by routing the sample through a heated catalytic CO scrubber. This Auto Reference function corrects zero drift and reduces the effect of interferences.





















