Luminous Flux
-
product
LED Goniophotometer For Led Tester
CX-880
Shenzhen Chuangxin Instruments Co., Ltd.
880 LED Test machine is used to measure: 1.the luminous intensity dirstribution curve, 2.intensity data, 3.spread angle and equivalent luminous flux of small lamps.
-
product
Integrating Spheres
IP-Series
Photometric Integrating spheres are used for evaluation of luminous flux of light sources & luminaires with a single measurement & for comparative analysis. The sphere is an essential tool for photometric research laboratories & lamp/luminaire manufacturers.
-
product
LED Tester0.3m-2m Integrating Sphere
CX-8000
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
product
High Power LED Photo-color-semi Automatic Selector
Shenzhen Chuangxin Instruments Co., Ltd.
Can divide LED in to several groups by chromatic coordinates, correlated color temperature, dominant wavelength or luminous flux.
-
product
Light-resistant Integrating Sphere
The integrating sphere is used for total luminous flux measurement. It uniforms the light by spatially integrating the collected light of light source. The integrating sphere has highly reflective diffusing plates formed on the spheres internal surfaces. These plates repeatedly scatter light rays from the light source with in the sphere to all other points to deliver uniform brightness distribution so measuring a portion of that light gives the total luminous flux. These years, the usage of integrating sphere for total luminous flux evaluation of light source is increasing. The large size integrating sphere over 1.5M is required for measuring a high brightness light source and a long light source such as fluorescent light.
-
product
Spectroradiometer
Spectroradiometer is usually used with a integrating sphere to measure the photometric and colorimetric parameters of all kinds of lamps. Relative spectral power distribution P(λ), chromaticity coordinate (x,y), (u,v), correlated color temperature Tc, color rendering index Ra, dominant wavelength, peak wavelength, spectral bandwidth, color purity, color ratio, SDCM, luminous flux, etc.
-
product
Photometric Probes for Illuminance
LPPHOT03… Series
The probe LPPHOT03 measures illuminance (lux), defined as the ratio between the luminous flux (lumen) passing through a surface and the surface area (m²). The spectral response curve of a photometric probe is similar to the human eye curve, known as standard photopic curve V(λ). The difference in spectral response between LPPHOT03 and the standard photopic curve V(λ) is calculated by means of the error f’1.
-
product
Photometers & Colorimeters
Instrument Systems Optische Messtechnik GmbH
A photometer is used to measure the photometric quantities of illuminance (lx), luminous intensity (cd), luminous flux (lm), and luminance (cd/m²). The integral method and the fast response time of silicon photodiodes means that photometers can achieve an outstanding measuring speed. They are therefore ideal for performing fast goniophotometric measurements. We take great care in the development and production of photometer heads and use innovative amplifier technologies.
-
product
Light Meters For Photometry
Comprehensive range of solutions for the measurement of illuminance (lux), luminance (cd/m²), luminous flux (lumens) and luminous intensity (cd).
-
product
Integrating Spheres
Instrument Systems Optische Messtechnik GmbH
Determination of radiant power or luminous flux from light sources with the aid of integrating spheres is one of the most important procedures in photometry. Designed as a hollow sphere whose inner surface is coated with a diffusely reflecting material, the integrating sphere ensures complete integration and mixing of light radiation. This is then output on a detector port for measurement.
-
product
GO-NR1000 Near-Field Goniophotometer
Hangzhou Everfine Photo-E-Info Co., LTD
Suitable for LED light source, LED chip, module and other small light source, the principal function includes: spatial light intensity distribution curve, spatial color distribution curve, iso-lux curve, total luminous flux, effective luminous flux, spatial luminance curve, etc.The test data can be saved as IESNA (*.ies), CIBSE (*.cib), EULUMDAT (*.ldt), CIE (*.cie), CEN (*.cen) and other formats, which can be directly used as the input data of international general lighting design software. Spatial luminance data can be imported into near-field lighting generation software to generate light data that can be imported into third parties (TracePro and LightTools).
-
product
Spectrometer & Colorimeter
Spectroradiometer is widely used to measure the spectral, photometric and colorimetric parameters of all kinds of lighting sources which usually include relative spectral power distribution P(λ), chromaticity coordinate (x,y), (u,v), correlated color temperature(CCT), color rendering index(CRI), dominant wavelength, peak wavelength, spectral bandwidth, color purity, color ratio, luminous flux, Illuminance, luminance, spectral transmittance and reflectance, etc. PIMACS provides different types of spectroradiometers and colorimeter to meet the requirements in laboratories or on production lines. They are applied in the measurement for general light sources, LED & OLED products, displays, etc.
-
product
Illuminance (lux) Probe
LPPHOT01
The LPPHOT01 probe measures illuminance (lux) defined as the ratio between the luminous flux (lumen) passing through a surface and the surface area (m2).
-
product
LED Lighting Test Instrument Integrating Sphere
CX-I.5S
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
product
Integrating Sphere
The simpler way to measure the total luminous flux of lamps and luminaires is to use an integrating sphere photometer system. It is a device to perform spatial integration of flux optically, thus the total luminous flux can be measured with one fixed photometer head and measurement can be instant. An integrating sphere photometer is calibrated with a total luminous flux standard lamp. A test light source is measured by comparison to a standard lamp calibrated for total luminous flux.
-
product
GO-R5000 Full-Field Speed Goniophotometer
Hangzhou Everfine Photo-E-Info Co., LTD
The GO-R5000 integrates more powerful functions such as near field, middle field and far field distribution goniophotometer, which can be used for spatial luminous intensity distribution and total luminous flux test of indoor lighting lamps, floodlights, street lamps, etc. Equipped with imaging luminance meter and spectroradiometer, it can measure the spatial luminance distribution and spatial spectral color distribution of the light source.
-
product
Luminance Colorimeter
XYL-VI
The XYL-VI Luminance Photoelectric Colorimeter changes the traditional structure thoroughly, employs the digital X(λ), Y(λ), Z(λ) sensors to replace the traditional analogue sensors, employs the digital signal measurement system to replace the traditional analogue measurement system. The instrument has no analogue unit, thus it is very simple to overcome the zero drift that is impossible to be avoided in traditional colorimeter. The digital sensor has a large dynamic range. Moreover, it possesses strong anti-interference ability and it has high accuracy. The XYL-VI Luminance Colorimeter contains internal RS232 computer interface. The calibration is done by software. It is suitable for monitoring and remote applications. The XYL-VI Luminance Colorimeter can be calibrated by XYL-VI Luminance Colorimeter software to sample the data and print out the results. It can also be corrected by other standard light sources to obtain very high measuring accuracy of x, y color coordinates and color temperature. It is a real-time measuring system and run under Windows2000/XP.
-
product
Heat flux plate
HFP01
Hukseflux Thermal Sensors B.V.
The HFP01 heat flux plate (also called heat flux sensor) offers a solution for measuring heat fluxes. HFP01 is the world's most popular sensor for heat flux measurement in the soil as well as through walls and building envelopes. By using a ceramics-plastic composite body the total thermal resistance is kept small.
-
product
Imaging Luminance Meter
CX1000
Hangzhou Hopoo Optoelectronics Technology Co., Ltd
CX-1000 imaging brightness meter is used to measure the brightness, brightness distribution and uniformity of LED modules, lamps, lamps, displays, street brightness and other light sources.
-
product
Industrial heat flux sensor
HF05
Hukseflux Thermal Sensors B.V.
The HF05 heat flux sensor is used to measure heat flux in industrial environments. It is covered with a stainless steel cover.
-
product
Automated Soil CO2 Flux System
LI-8100A
A portable, automated system for simple and reliable survey and long-term measurements over a study site. The LI-8100A Analyzer Control Unit contains an infrared gas analyzer and a connection panel to interface with the 8100-103 Survey Chamber, the 8100-104 and 8100-104C Long-Term Chambers, additional gas analyzers, and the LI-8150 Multiplexer.
-
product
Image Resolved Luminance Measuring Camera
LMK 6
TechnoTeam Bildverarbeitung GmbH
The LMK 6 is TechnoTeam's luminance measurement camera and used in many ways as a standalone measuring device. It is designed to be compact and lightweight and can be used in almost any light measurement application. As it is one of TechnoTeam's core products it is also used in our other camera based measurement systems.
-
product
Luminance Colorimeter
BM Series
There are various lineups such as hand-held type and measurement of ultra low luminance in short time.
-
product
Flux Meter
NF-100
NF-100 can perform stable high accuracy measurement because noise and drift are reduced by the structure of digital counter and integral V/F converter with use of operational amplifier.
-
product
Digital Luminance Meters
All kinds of screen luminance measurement, surface luminance measurement.
-
product
Heat, Vapor, and Carbon-Dioxide Flux Sensors
Heat, vapor, and carbon-dioxide flux sensors are typically used in eddy-covariance systems to measure exchanges of carbon dioxide, water vapor, and heat between the surface of the earth and the atmosphere.
-
product
Neutron Flux Monitoring Systems
To monitor reactor core neutron flux and provide indication during all modes of reactor operation, and to provide trip signals to the Reactor Protection System (RPS) and the Reactor Manual Control System (RMCS).





























