Humidity
-
Product
Web Sensor
T3510
-
Web Sensor with built-in relative humidity and temperature sensors. High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
Product
Temperature Chambers & Humidity Chambers
-
Temperature and humidity test chambers are available as standard products in a variety of sizes to suit your needs. Our environmental test chambers are often used for steady-state stability testing, basic temperature cycling and accelerated stress testing.
-
Product
Environmental Testers
-
AEMC manufactures a line of cost effective, hand-held instruments for measuring temperature, humidity, light, wind speed and other variables. Each instrument in this series includes sensor, backlit CD and a shockproof holster. They are battery operated and can easily be carried in a shirt pocket.
-
Product
Thermo-Hygrometer
S3541
-
Data logger is designed for record of temperature and humidity. Values are stored to a non volatile electronic memory. Data transfer to the personal computer for further analysis is performed via USB, RS232, GSM or Ethernet interface by means of a proper communication adapter.
-
Product
Vehicle Test Chambers
-
Our dynamometer chambers feature dependable mechanical refrigeration, superior air flow, and expansive control systems. Our dynamometer drive-in vehicle test chambers are designed to integrate directly with a dynamometer system, while simultaneously exposing vehicles to a wide variety of environmental conditions including temperature and/or humidity, rain, wind, and more. Our control systems allow for precise temperature and humidity testing while meeting your exact specifications.
-
Product
Voltage Controlled Oscillators
-
a High Reliability Low Noise Voltage Controlled Oscillator (VCO) which covers a 10 MHz to 20 MHzfrequency band with a voltage tuning range from 0V to 20V. This design features exceptional phase noise performance of -120dBc/Hz @ 10 kHz offset. Supply Voltage is +15V with a generated output power level of +10 dBm and 2nd harmonic output of-11 dBc typical. The assembly is RoHs compliant and available in a compact 0.5 inch SMT package with an industry standardmounting footprint. The bottom surface is copper clad with 2-5 micro inches of immersion Gold over 150 - 250 micro inchesof Electro less Nickel which makes it resistant to oxidation for ease of soldering. The VCO operates over a temperature rangeof -40°C to +85°C and is designed to meet a variety of MIL-STD-202 test conditions including Humidity, Shock, and Vibration.
-
Product
PMC Module
PMC-1553-TACEx
-
Operating temperatureCommercial: 0 to +70 °COptional: -40°C to +80°C• Airflow requirement: .5 CFM• Humidity: 5 to 90% (non-cond.)• Altitude: 0 to 20’000 ft
-
Product
Environmental Test Chambers
ET-Series
-
Environmental Test Chambers are designed with uncompromised features included in the system to meet your changing application needs of simulation of wide range of temperature, relative humidity etc., conditions without the added cost of expensive add-on’s as options. Available in varied volumes to fit your differing specimen sizes
-
Product
Enlarge Environmental Chamber
REXMED REC-480
-
MOD. REC-480, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 5,270 Watts, 18,000 BTU/hr, 4,545 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
Product
Temperature Humidity Meters
-
Measure and record temperature and humidity readings anywhere.
-
Product
Thermo-Hygrometer
D3121P-2
-
Thermometer, hygrometer is designed for measurement and datalogging of temperature, relative humidity for compressed air up to 25 bars with 2 meters cable into the internal non-volatile memory.
-
Product
Temperature and Humidity Control Systems
-
ETS 5000-Series controllers—with an industry-leading combination of features and economy—feature dual-function controllers for humidity, temperature, and third parameter control (e.g. pressure or oxygen). Our latest generation of microprocessor (PID) controllers offer precision and accuracy and can be used with or without software. All controllers include a sensor.
-
Product
Hygrometers
-
Hygrometers are the devices that are useful in detecting moisture content of the atmosphere. These are important tools that allows users to make sure that the atmosphere of certain places does not have high or very low humidity. Both high and low humidity has adverse effect on human health. High humidity at certain places allows moulds to grow and damage the place while low humidity can cause wooden furniture to be wrapped and even ruined. Moulds can trigger different health problems, including allergic reactions and respiratory disorder.
-
Product
Steady State and Constant Climate Chambers / Rooms
-
is ideal for reliable stability tests and precise maintenance of constant climatic conditions. Constant temperature and humidity values are the outstanding features of this range. These constant climate chambers have large reserve capacity and a variety of optional features.
-
Product
Web Sensor
P8511
-
Web Sensor P8511 is designed to connect one probe. To Web Sensor P8541is possible connect up to four probes. Temperature or humidity probes are available asoptional accessories
-
Product
Transmitters for Pressure, Humidity, Temperature, CO2
-
Wuntronic Transmitters for Pressure, Humidity, Temperature, CO2
-
Product
Premium Data Loggers with 1-4 Channels
-
Premium Data Loggers for temperature, humidity, co2, atm. Pressure, voltage, current, pulse and 2-state inputs.
-
Product
Temperature/Relative Humidity Logger-25 to +50C/0 to 100% RH
TV-4500
-
This unit records temperature and humidity using self-contained sensors. It can record temperatures between -25 to +50C and relative humidity between 0 to 100%. The unit is waterproof so it can be used outside.
-
Product
PV Accelerating Tester
-
King Design Industrial Co., Ltd.
*Spectrum mis-match: IEC 60904-9 class A*Non-uniformity <5%*Instability <5% ( within 30 mins)*Irradiance range: 800 W/m2 ~ 1200W/m2*Effective range: 30cm x 30cm; 1.1m x 1.4m*(customize accepatble)*Temperature:40℃ ~ 90℃*Humidity: 20% ~ 85%
-
Product
Ethernet & Wireless Data Loggers
-
Dataloggers with Ethernet or wireless interfaces for temperature, humidity, pressure and process inputs.
-
Product
75% Satured Solution for RH Sensor
HD75
-
75%RH saturated solution for checking the relative humidity sensor, complete with screw adaptor for probes ∅ 14mm, M12×1 thread.
-
Product
Precision Condenser Microphone
2575
-
Performance:Nominal Microphone Diameter1"1" Frequency Response: Characteristic (at 0 incidence) Random IncidenceRandom Incidence Open Circuit Sensitivity: 45 mV/Pa Resonant Frequency (90 Phase Shift)8000 Hz8000 Hz[1] Inherent Noise<10 dB(A) re 20 Pa<10 dBTemperature Range (Operating)TBD FTBD C Humidity Coefficient of Sensitivity (0 to 95%, non-condensing)0.001 dB/%RH
-
Product
Remote CO2 Concentration Thermometer Hygrometer
H6520
-
Sensor H6520 is designed for online monitoring of temperature, relative humidity of air without aggressive substances. Other devices are controlled by two relay outputs.
-
Product
Anemometers
-
Use the latest science to simply and effectively measure airflow and volume as well as temperature and humidity.
-
Product
COMETEO Multi-Plate Radiation Shield
F8100
-
Newly developed meteorological screen for humidity and temperature transmitters. Passive solar radiation and weather shelter for meteo sensors.
-
Product
Compressed Air RH+T Transmitter
T3419P-2
-
Humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.
-
Product
Temperature Humidity Chamber
-
Xi'an LIB Environmental Simulation Industry
Designed to simulate precise environmental conditions for testing materials, components, and products.
-
Product
Constant Temperature Humidity Test Chamber
-
Constant Temperature and Humidity Test Chamber from Weiber are environmental test chambers, designed to simulate constant climatic conditions for testing a wide variety of products for their quality, performance, shelf life and stability. They are used to simulate constant temperature and humidity conditions, thereby creating a physiologically ideal environment for product testing. These equipments are most commonly employed for testing electrical devices, electronic parts and components, instruments, biological samples, food items and other manufactured and processed goods and find widespread usage in scientific research organizations, semiconductor industries, material research institutes and other industrial and manufacturing units.
-
Product
Testing Released Water Vapor
Humiditest™ Complete System
-
The James Instruments Humitest System allows the concrete practitioner to monitor and ensure that a new structure is dry enough to proceed with the next phase of construction. This is especially critical for concrete structures requiring a coating, carpeting or similar floor or covering treatment. Installing such treatments before the concrete is sufficiently dry will typically cause expensive failures in the covering treatment. The only accurate way to ensure that the concrete is sufficiently dry enough to safely avoid expensive re-work is via a bore hole humidity test system, such as the Humitest System
-
Product
Temperature and Humidity Transmitter
T3319-4
-
Humidity, temperature probe on a cable. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio, specific enthalpy.