Filter Results By:
Products
Applications
Manufacturers
-
product
EMI Filtering Analyzer
RS Analyst™
With RS Analyst circuits can be analyzed prior to fabrication to determine whether radiated susceptibility requirements will be satisfied. RS Analyst is ideally suited for predicting the effectiveness of EMI filtering for power line and signal line filters and for determining the effects of cable shielding and shield terminations.
-
product
NEXTest 7
PK-2030/2032/2033/2036/2037/2038
NEXTest 7 is an advanced and unique tester in the market. It's designed to check and troubleshoot the pin connections of Display port & HDMI prior to installation on equipment. By using advanced technology to verify the integrity (20 pins + shield) of both display port and HDMI cables, especially for HDTV installation and DIY termination in the field, solving your cable testing need, unlink all of the other testers verify 9 circuits only. It checks for opens, shorts, miswires and intermittent faults in all conductors plus shield continuity, most tester only test for opens. It displays cable map results of both TX (near end) and RX (far end) on the main unit, either on testing before or after installation cables. User can easily read and determine the actual 21 pins configuration on main unit. It employs both auto and manual scanning of 21 wires. Tone Generator mode transmits two selectable tones on each pin for use with Net Probe (PR-06P) optional, enables one to quickly locate a cable. It's capable of testing up to 8 cables and locations at one time. NEXTest 7 especially features a self-learning mode to memorize cable pin out for testing large quantity standard or custom cables for PASS/FAIL a snap, makes testing quick and more efficient.
-
product
Shield
Arduino MKR ETH Shield
You may want to connect an Arduino MKR board with an Ethernet cable instead of using WiFi. An Ethernet connection can sometimes be stabler, faster, and more secure. To do this, plug in the Arduino MKR ETH shield.
-
product
Coax, Contact, Receiver, 20/26 GHz, SF142B, 90 Series modules only
610102109
Primary mating contact 610102110. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating 30µ" Au over 100µ" NiContact Termination Shield – Crimp/ClampInsulator PTFEMating Force 3.0 lbs max [1.36 kg]Electrical SpecificationsCharacteristic Impedance 50 OhmsFrequency Range DC to 26 GHzVSWR 1.15 + .01 (f) GHz w/ SF142 (20 GHz)Insertion Loss .06 x√f(GHz) dBDWV 800 V RMS Shield to center contact1000 V RMSContact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications SF142B Environmental SpecificationsOperating Temperature -65°C to +125°Vibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Coax, Contact, ITA, 75 Ohm HD, sm59/U Belden 1855A, 3 GHz
610102132
Primary mating contact 610102133. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – brassCenter contact – BeCuContact Plating Center conductor shield –30µ” Au over 100µ” NiContact Termination Center conductor - SolderShield - CrimpInsulator PTFEMating Force 2.0 lbs max [0.91 kg]Electrical SpecificationsCharacteristic Impedance 75 ΩFrequency Range DC to 3 GHzVSWR ≤ 2.26 @ 3 GHzInsertion Loss -0.86 dB MaxDWV 800 VDC min.Contact Resistance 5 mΩ center/ 3 mΩ outer Cable Specifications sm59/U Belden 1855AEnvironmental SpecificationsOperating Temperature -55°C to +125°CVibration MIL-STD 1344, Method 2005, Test Condition 4Shock MIL-STD 1344, Method 2004, Test Condition AInsulation Resistance 1000 MΩ min.
-
product
Qwiic Connect System
An ecosystem of I2C sensors, actuators, shields, and cables that make prototyping faster and less prone to error.
-
product
Twinax Contacts
VPC twinax contacts provide differential voltage options most commonly used in digital and data applications.For increased reliability and to eliminate the need for polarization, the design of VPC's twinax contact consists of two concentric inner conductors for termination to the twisted pair, and an outer shield for termination of the cable shield.
-
product
Twinax Modules
VPC twinaxial contacts provide differential voltage options most commonly used in digital and data applications. For increased reliability and to eliminate the need for polarization, the design of VPC's twinaxial contact consists of two concentric inner conductors for termination to the twisted pair, and an outer shield for termination of the cable shield.
-
product
DataComm & LAN Testers
Tests & troubleshoots voice communication for open circuits, shorts, miswires, reversals, and split pairsSHIELD detection tests a cable’s shield integrityEasy to read fault display and high speed testingDebug mode for detailed fault identification resultsNetworking Cable Tester has auto sleep mode and power off switch to decrease power consumptionBattery low LED indicator
-
product
3-m, 78-pin Dsub Cable
Y1138A
Connect this M/F twisted pair with outer shield cable to 34980A multifunction switch/measure mainframe and modules
-
product
Shield
Arduino Ethernet Shield 2
The Arduino Ethernet Shield 2 connects your Arduino to the internet in mere minutes. Just plug this module onto your Arduino Board, connect it to your network with an RJ45 cable (not included) and follow a few simple steps to start controlling your world through the internet. As always with Arduino, every element of the platform – hardware, software and documentation – is freely available and open-source. This means you can learn exactly how it's made and use its design as the starting point for your own circuits. Hundreds of thousands of Arduino Boards are already fueling people’s creativity all over the world, everyday. Join us now, Arduino is you! *Requires an Arduino Board (not included)
-
product
Coax, Contact, Receiver, 20/26 GHz, Flex 402
610102119
Coax contact, Receiver, 20/26 GHz, Flex 402 (Only available in patchcords).Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating 30µ" Au over 100µ" NiContact Termination Shield-SolderInsulator PTFEMating Force 3.0 lbs max [1.36 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 26 GHzVSWR 1.25 for 2 - 18 GHz1.30 for 18 - 26 GHzInsertion Loss .06 x√f(GHz) dBDWV 800 V RMS Shield to center contact1000 V RMSContact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications Flex 402 (Only Available in Patchcords)Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition AInsulation Resistance 2000 MΩ Min.
-
product
LAN Tester
RJ45
This easy to operate LAN tester enables you to test your wiring and connections at installation or after maintenance, making it one of the most convenient tools on the market. With the press of a single button you can automatically run a barrage of tests, including tests for Continuity, Opens, Shorts, Crosses and Splits. You can also identify which pairs require correction; The unit will scan all combinations without you having to do anything other than initiate the test. Even cable shield is tested for continuity! Building on the features provided by other testers such as the CZ20250, this LAN tester will also test coax networks and provide a tracing tone for cable identification. And it tests for all these at lightning speed, saving you as much time as possible.
-
product
MP CI set
The MP CI set up to measure coupling impedance is used to determine EMC characteristics of connectors and cables. The coupling inductivity defines the coupling inductance of external disturbance on the shield or on the ground with the desired signals. If the coupling inductivity is considered in the construction set-up and the pin or wire assignment of connectors or cables, then the connectors or cables will be more interference-resistant. The MP CI set-up for measuring coupling impedance can be used for following measurements at connectors or cables: 1. measurement of a single signal (common mode) 2. measurement of a symmetrical signal (common mode) 3. measurement of a symmetrical signal (differential mode)
-
product
Coax, Contact, ITA, 20/26 GHz, 3.5MM, w/ SMA Adapter, 90 Series Modules only
610102134
Coax, Contact, ITA, 20/26 GHz, 3.5MM, with SMA Adapter (90 Series modules only)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – brassCenter conductor – BeCuContact Plating 30µ" Au over 100µ" NiContact Termination 3.5mm compatibleInsulator PTFEMating Force 3.0 lbs max [1.36 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 26 GHzVSWR 1.15 + .01 (f) GHzInsertion Loss .06 x√f(GHz) dBDWV 800 V RMS Shield to center contact1000 V RMSContact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications 3.5mm compatibleEnvironmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MΩ min.
-
product
Board
Arduino Mega 2560 Rev3
The Arduino Mega 2560 is a microcontroller board based on the ATmega2560. It has 54 digital input/output pins (of which 15 can be used as PWM outputs), 16 analog inputs, 4 UARTs (hardware serial ports), a 16 MHz crystal oscillator, a USB connection, a power jack, an ICSP header, and a reset button. It contains everything needed to support the microcontroller; simply connect it to a computer with a USB cable or power it with a AC-to-DC adapter or battery to get started. The Mega 2560 board is compatible with most shields designed for the Uno and the former boards Duemilanove or Diecimila.
-
product
Multi-Modular Cable Tester
MT-7051N
Tests RJ45 TIA568A/B (AT&T 258A), 10 Base-T, Token ring, RJ-11/ RJ-12 USOC and Coaxial BNC cable.Automatically check cable for continuity, short, open and crossed wire pairs.Coaxial cable port indentifies cable conditions including shorts, shield opens and center conductor breaks.Main unit and remote allow one person testing.Power source: DC 9V BatteryDimension: 102x106x28 (mm)Cable not include
-
product
RF Semi-Rigid Cable Assemblies
The Semi-Rigid cables are available with a copper or aluminum jacket and available with a selection of different platings and 4 different diameters (.047", .085", .141" & .250"). The Conformable®, or Hand-Formable (BJ - Braided Jacket), has a tin filled braid with a metal foil underlay and is also available in the same diameters as the Semi-Rigid type . The Flexible version, our Mini-Flex, has an FEP jacket, round braid and inner spiral shields and is available in 2 diameters, .105" &.165". All 3 types (Semi-Rigid, Conformable & Mini-Flex) are manufactured using the same type dielectric core and have virtually the same electrical performance. The decision of which cable to use should be primarily based upon your application.
-
product
Twinax, Contact, Receiver, 50 Ohms
610113144
For increased reliability and to eliminate the need for polarization, the design of VPC’s Twinax contact consists of two concentric inner conductors for termination to a twisted pair, and an outer shield for termination of the cable shield.
-
product
SparkFun Spectral Sensor Breakout
AS7263 NIR (Qwiic)
The SparkFun AS7263 Near Infrared (NIR) Spectral Sensor Breakout brings spectroscopy to the palm of your hand, making it easier than ever to measure and characterize how different materials absorb and reflect different wavelengths of light. The AS7263 Breakout is unique in its ability to communicate by both an I2C interface and serial interface using AT commands. Hookup is easy, thanks to the Qwiic connectors attached to the board --- simply plug one end of the Qwiic cable into the breakout and the other into one of the Qwiic shields, then stack the board on a development board. You’ll be ready to upload a sketch to start taking spectroscopy measurements in no time.
-
product
ITA, G6, 6 Module, Oversized Backshell
410104732
This oversized backshell for the G6 ITA features an adjustable cable exit that can accommodate cable bundles up to 2.50". To accommodate cable exit size variations, excess shield material may be snapped off via a perforated design.This backshell also allows for an increased bend radius which is necessary for many wiring configurations including high speed due to larger wire sizes.Compatible with p/n's 310104318, 310104336, and 310104344 and the G6 ITA is backwards compatible with the G6X Receiver (310104481).
-
product
LANTRACKER
PH-100/120
The Lantracker is a network tester, pin-by-pin cable tester, and tone generator all in one. As a network tester, it detects whether a network is active or inactive and displays network speed (10/100/1000 Mbps) in either case. It also flashes the network hub or NIC’s port light corresponding to the cable it is connected to, to show the cable’s port number. As a cable tester, it performs loop-back or remote tests of network, data, voice, and coaxial cables, displaying the results on a pin-by-pin LED display which moves from pin to pin automatically or manually. The Lantracker can be used to test cable or shield integrity, testing network function and speed, and tracing cable using its tone generator function (tone probe not included). Includes an adaptor for testing coaxial-F cable. Uses 1 9V battery.
-
product
SHC68-68-EPM, 68-Pin Male VHDCI to 68-Pin Female D-SUB, 80 Twisted Pairs, Shielded Multifunction Cable, 1m
192061-01
The SH68M-68F-EPM Cable, sometimes referred to as SHC68-68-EPM, connects DAQ devices to accessories or cables with D-SUB connectors. You can use this cable to create custom cabling for your DAQ device. The SH68M-68F-EPM Cable is offered in different lengths. 80 twisted pairs, 1 connection used in shield. 81 total connections used.
-
product
Cable Tester
CT100
The intelligent, CPU-controlled CT100 accepts virtually any connector type: XLR, mono and TRS phone ( 1 /4 ", 1 /8 ", TT), RCA and MIDI. It shows which input pin is connected to which output pin. Separate LED's indicate proper shield connection and phantom power presence. The CT100 also offers an installed cable test mode and a continuity check plus a test tone generator.
-
product
Coax, Contact, ITA, 20/26 GHz, SF142B, 90 Series modules only
610102110
Primary mating contact 610102109. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating 30µ" Au over 100µ" NiContact Termination Shield – Crimp/ClampInsulator PTFEMating Force 3.0 lbs max [1.36 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 26 GHzVSWR 1.15 + .01 (f) GHz w/ SF142 (20 GHz)Insertion Loss .06 x√f(GHz) dBDWV 800 V RMS Shield to center contact1000 V RMSContact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications SF142B Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Multimeter Network Tester
VA16
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Network Cable test (RJ45): Tests for open circuits, shorts, miswires, reversals, and split pairs SHIELD detection tests a cabl
-
product
100 Ohm Twinax Cables
PE-S330
PE-S330 part number from Pasternack is a PE-S330 twinax cable that is flexible. Pasternack PE-S330 flexible twinax cable is 100 Ohm and has a PE dielectric. Our PE-S330 twinax is constructed with a 0.33 jacket made of PVC. PE-S330 twinax has a shield count of 2 and the maximum frequency for this Pasternack cable is 400 MHz.
-
product
SCB-68A, Noise Rejecting, Shielded I/O Connector Block
782536-01
68-Pin Female Screw Terminal to 68-Pin Female D-SUB, DIN-Rail, Shielded I/O Connector Terminal Block - The SCB-68A provides a shielded I/O connection for interfacing I/O signals to plug-in data acquisition devices with 68-pin connectors. This Terminal Block combines with shield cables to provide low-noise signal termination. The SCB-68A incorporates a completely redesigned mechanical enclosure with a magnetic removable lid, DIN-rail mount compatibility, and a resettable fuse. It is compatible with single- and dual-connector Multifunction I/O with 68-pin connectors. The SCB-68A also includes two general-purpose breadboard areas and an onboard cold-junction compensation sensor.
-
product
Conducted Susceptibility Analyzer
CS Analyst™
With CS Analyst circuits can be analyzed prior to fabrication to determine whether conducted susceptibility requirements will be satisfied. CS Analyst is ideally suited for predicting the effectiveness of EMI filtering for power line and signal line filters and for determining the effects of cable shielding and shield terminations.
-
product
Plug'N Check
PH-320/300
The plug‵N′check is our easiest-to use cable tester yet. Simply plug in both ends of a cable, and the easy-to-read LED display explains the cable type and checks whether cable is faulty or good automatically. A shield LED shows results of the shielding check and battery low indicator saves you from misreading the tester in case of low power. Will make work shorter and easier for the layman and the professional alike. Especially suited for installation and maintenance of residential networks.