Load Banks
Test a power source by providing controlled amounts of load to create conditions found in thier application.
See Also: AC Load Banks, DC Load Banks, Inductive Load Banks, Reactive Load Banks, Resistive Load Banks
-
Product
Load Banks
EL08 Series
-
*Rectifier Test 8kW*All of our Load Banks are continuously rated for Power and Current.
-
Product
LB-Series Digital AC Load Banks
-
The LB-Series AC Load Banks are designed for high power portable load testing of generators, UPS, and other critical AC power sources. Available models meet a range of voltages including but not limited to 208, 380, 440, and 480 VAC. Load power model options reach 1000 kW standard with other options available.
-
Product
AC Load Banks
-
Guangdong EMAX Electrical Co., Ltd.
We offer AC load banks in a variety of capacities and any voltage combination, with custom models including resistive, inductive, capacitive or resistive/reactive combination loads, all tailored to meet any load testing requirement.
-
Product
Three Phase Load Bank
REOLOAD 310
-
A three phase load bank rated for 48kW, with fan cooling. The front panel layout includes a switch panel for configuring the separate resistor modules to give the required resistance and current range. There are also digital panel meters for displaying the phase voltages and currents. An interface for PLC control is also provided.
-
Product
AC Load Banks
X100L-600 Series
-
Mosebach Manufacturing Company
Mosebach’s X100L-600 is the smallest load bank of 100 kW with 5 kW resolution. Offers a continuous load at 600/480/240/208 volts. Great for most generator testing. And lightweight – only 64 lbs!
-
Product
Radiator Mount Load Banks
-
Mosebach Manufacturing Company
Help prevent wet stacking in diesel gensets with a radiator or duct mounted load bank. Being a supplemental load, Mosebach has a solution to fit your needs.
-
Product
Dc Load Bank
-
Highly reliable and durable new alloy resistor is used for the JUNXY DC load bank. It is thermal shrinkable and seal installed in the stainless steel pipe, whose surface with insulated heat sink. The resistor is moisture-proof, anti-corrosion, good heat dissipation, high insulation resistance, safe and reliable.
-
Product
Variable Resistor Load Bank
REOLOAD 100
-
A variable resistor load-bank with fixed stages connected in parallel and switched in, as required, with an adjustable stage for fine trimming. Designed for testing equipment under load. 1000V (AC or DC). 250A and 2500
-
Product
Rack Mounted Load Banks
-
Traditional commissioning is a daunting task. Since formal system operation doesn’t begin until the system is commissioned, the commissioning team experiences intense pressure to complete the commissioning process quickly. Commissioning can involve high expense and requires staffs from different departmental disciplines to work together. For these reasons data center commissioning has almost uniquely been associated with large data centers (over 20,000 ft2 or 1,858 m2). In the recent past, many data center managers chose to roll the dice and perform little or no commissioning, relying only on start-up data to press ahead with launching the new data center. Given the reality of 24x7 operations, however, the alternative of exposure to major system failures and accompanying downtime is no longer an economically viable option. Commissioning has now become a business necessity. JUNXY series AC & DC rack mounted load banks can be used to introduce heat loads and to allow for simultaneous testing of both electrical and cooling systems.
-
Product
High Current Electrosurgical Analyzer
Uni-Therm
-
A unique high power low inductance load bank enables performance testing up to 8 ampere RMS with a duty cycle of up to 100% making the analyzer an extremely versatile test instrument for calibrating and performance testing of conventional and high power electrosurgical generators. The load bank allows testing in a range of 0-5115 with a resolution of over 1000 steps providing high detailed power profiles. The Rigel Uni-Therm also advocates safe working practise by providing all necessary resistors within a single enclosure.
-
Product
SMART Constant Current DC Load Banks
SLB-Series
-
SMART Constant Current DC Load Banks are designed for acceptance testing, discharge testing, battery capacity testing, battery maintenance, engineering examination and other testing for DC power with load. The SMART technology allows a constant current discharge without the need for manual adjustment of current during the discharge test. Our SLB-Series load banks are portable, durable, economic, safe, easy-to-use and come complete with our DataView software, providing the user with a complete data management and analysis program.
-
Product
AC Load Bank (Resistive)
K-1000 Resisitive
-
Kongter Test & Measurement Co., Limited
The kW of a resistive load bank is “real” power in electrical terms. When a resistive AC load bank is used to test an engine generator set the engine will produce its full horsepower rating, dissipate engine exhaust gases, and produce thermal energy into the engine cooling system. The resistive load bank in fact, will completely test the engine and its various systems.
-
Product
Battery Data Logger
BDL-3926C
-
Kongter Test & Measurement Co., Limited
BDL-3926C Battery Data Logger is wireless monitoring device for string voltage, cell voltage, current and temperature. It works individually to reflect battery status or co-works with Kongter’s other battery test equipments like battery charger and K-3980 DC load bank. For different battery systems, it has customized configuration from 12V to 480V or upper. And it has easy expansion for all battery systems.
-
Product
Resistive AC Load Bank
-
AC load bank testing offers you whole solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated AC & DC load bank could be made in one unit or separately with different load voltages as per your need for different applications.
-
Product
Resistive & Capacitive AC Load Bank
RCD
-
RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test.
-
Product
AC Load Bank (Resistive/Capacitive)
K-1000 Resistive/Capacitive
-
Kongter Test & Measurement Co., Limited
A RCD (resistive/capacitive) generator load bank is non-linear load bank. The electronic and non-linear loads simulated by capacitive load banks are typical of the Telecommunications, Computer or Uninterruptible Power Supply (UPS) Industries.
-
Product
AC Load Bank (Resistive & Inductive)
K-1000 Resistive & Inductive
-
Kongter Test & Measurement Co., Limited
Kongter resistive & inductive AC load banks are used to simulate the motor loads or other electromagnetic devices working at their rated power factor. Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive testing from a single unit.
-
Product
DC Load Banks
-
Power House Manufacturing, Inc.
DC load banks by Power House Manufacturing are offered in any voltage from 6 to 1,000 Volts DC.
-
Product
Combined Load Banks
C-Series
-
C-series combined load banks are devices which contain resistive and reactive loads, apply the load to an electrical power source and dissipate the power of the electrical power.
-
Product
Battery Capacity Tester
BLU-T Series
-
Battery load bank BLU-T is a powerful and lightweight solution designed for condition assessment of telecommunication and radio equipment backup supply. This instrument can perform the battery capacity test on battery strings such as Pb, Li-ion, Ni-Cd, and others. It tests battery strings with voltages in the range of 0,9 – 70,5 V DC. As a special feature, the BLU110T model enables capacity testing of single PB, Ni-based as well as Li cells (with current up to 100 A).The capacity test is conducted in an accurate, user-friendly way. Also, it is in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.BLU-T battery load bank enables setting the discharge current up to 350 A, with 0,1 A resolution. If higher currents are required, the BLU-T units can be connected in parallel, or BXL-T additional load units can be linked.The instrument offers a high power-to-weight ratio. BLU-T series has models starting from 12,8 kg / 28.2 lbs and up to 19,2 kW of power.A user can select one of three discharge modes: Constant current, Constant power, Constant resistance. Additionally, different battery duty cycles can be simulated using user-selectable discharge profiles.Discharge parameters can be monitored in real-time during the capacity test. A 4,3-inch touch screen shows overall battery voltage, discharge current, discharge test time and capacity during the entire test. Also, the capacity tester is compatible with DV-B Win software. A user can view a detailed numerical and graphical presentation of key parameters, and create reports in various formats.Testing can be carried out without disconnecting the battery from the service.
-
Product
AC Load Bank (Resistive/Reactive)
K-1000 Resistive/Reactive
-
Kongter Test & Measurement Co., Limited
Resistive/reactive load banks are great choices for testing turbines, switchgear, rotary UPS, generators and UPS systems. They can also be used for integrated system testing of utility substation protection systems, particularly for more complex relays like distance, directional overcurrent, power directional and others. A resistive/reactive inductive and/or capacitive load is often required to test solar inverters to ensure solar panels can be stopped from producing electricity in the event of a power outage.
-
Product
RLC Load Banks
-
Guangdong EMAX Electrical Co., Ltd.
Elevate your power testing capabilities with our RLC Load Banks. Engineered for precision and accuracy, these load banks deliver exceptional performance and control, ensuring the longevity of your power systems. Experience unmatched quality and reliability.
-
Product
Liquid-Cooled Load Banks
-
Guangdong EMAX Electrical Co., Ltd.
EMAX's liquid-cooled load banks are the best choice for industries and applications with their high efficiency, compact size, quiet operation and precise load testing.
-
Product
Generator Loading System
-
Mosebach Manufacturing Company
GLS (Generator Loading System) is a load bank for use with your generator to load it automatically to your set point. This will keep your generator running at its optimal point and reduce your maintenance costs. Fully programmable by you.
-
Product
AC Load Banks
XL300-400 Series
-
Mosebach Manufacturing Company
The XL300-400 Series of Load Banks offer 300 kW or 400 kW in various voltages in a compact, lightweight enclosure.
-
Product
Battery Testing System
C8000
-
The Cadex C8000 stands in a class by itself in flexibility and affordable price. Test SMBus batteries, monitor cell balance and capture load signatures to observe batteries with a unique load protocol. Add a thermal chamber, an external load bank, a safety circuit and alarm to form a command center and you begin realizing the unique qualities of this fine battery testing system.
-
Product
Load Bank
-
Being the reckoned names in the industry, we offer world-class range of Load Bank that is manufactured with perfection. We offer in different configurations such as Resistive, Inductive, and Capacitive. Our entire product range has high compressive strength and ensures smooth operations. They are durable in nature and are delivered in stipulated time frame.
-
Product
Multi-Channel Battery Testing
-
The Multi-channel system includes turnkey integration of Greenlight's environmental chamber, load bank, power supply and data acquisition system, all housed in 19" rack towers.
-
Product
Load Banks
-
The only way to be certain that your stationary batteries will perform to specification is to test the batteries’ capacity with a DC load bank / portable battery discharge tester.