Filter Results By:
Products
Applications
Manufacturers
-
product
Reflectometer
T-510
Techno Instrumentation (India) Private Limited
Pulse Echo, Impulse current and Decay methodprovided to get the distance to almost all typesof faults.Laptop based 15 inch display with user friendlyinterface for easy operation.Online support of experts to review fault graphs.Comparison feature of any 5 graphs for reviewand analysis to get more accurate results.Velocity of propogation(VOP) control makes iteasy to precisely pre-locate faults in cables withdifferent velocity.Automatic storage of more than 10,000 faultgraphs.
-
product
H-Field Burst Detector
BD 11
The BD 11 is used to detect a burst or ESD current pulse on a cable, for example in a complex system. This makes it easier to investigate the causes of sporadic faults in the system. It is small and handy, its sensitivity is very high and continuously adjustable.
-
product
SIRIO
4AAX4A
Sirio is a low-cost multi-function meter in a 4 DIN module, ideal for measurement and display of the most important electrical parameters.Sirio can be installed in single phase and three-phase unbalanced systems in a triangle or in a star layout with sturdy 4 mm2 terminals for measuring the current and voltage.It monts an 8 digits LCD display. It displays 7 major measures (True RMS) and more than 40 RMS are available on the integrated RS485 serial port.Siri0 include two relay outputs, user-configurable for alarms, pulse or remote control.All parameters are configurable from instrument keyboard already installed.
-
product
120 A Manual Pulse Width Extender
TLP-12012A6
High Power Pulse Instruments GmbH
- Pulse width extender for the high current TLP/HMM test system TLP-12010A and TLP-12010C- 6 manual selectable pulse width: 5, 10, 50, 100, 200 and 500 ns- High pulse output current up to ±120 A- High performance and high quality components
-
product
Pulse Current Generator Multi-Pulse Generator
Shanghai Guantu Technology Co., Ltd.
What is the difference between ordinary current and pulse current?The difference between ordinary current and pulse current: ordinary current is continuous and uninterrupted current.Pulse current is a current whose direction does not change and whose intensity changes periodically with time.
-
product
Military-Style DC Solid-State Relay for High-Current Pulse Load Applications
Part No. M33-2N
The M33-2N is a military-style DC solid-state relay designed for high-current pulse load applications. It features the latest power FET output technology to minimize ON resistance. This feature provides minimum output voltage drop and allows the M33-2N to switch high pulse currents up to 100 amps at higher temperatures than those allowable with bipolar devices. The M33-2N utilizes transformer isolation to protect against transients, and are through-hole mountedMSL 1 Available options include:M33-2 7Adc, 60Vdc Load; 4.5-5.5Vdc (bias voltage), 80µA (CMOS) Control;
-
product
Current Pulsers and Laser Diode Drivers (Pulsed Current)
These instruments generate current pulses whose amplitude is largely independent of the load voltage. This makes them ideal for pulsing device whose voltage may vary with time (for instance, the voltage drop of laser diodes may vary with temperature, or explosive squibs which change impedance during ignition). This voltage independence is a trade-off with speed. If faster rise times are required, consider using pulsed voltage instruments instead.
-
product
High Current SMU 1000 A
AXC7583
Generate extremely short, fully regulated current pulses from 300 µs up to 1000 A. At the same time, carry out measurements directly on the DUT with the integrated VMU and CMU. Perfect for rapid semiconductor tests during production.ven Bauteilen.
-
product
150 Amps, 10 MHz BW Current Probe - AC/DC , 500 Amp Peak Pulse
CP150
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
product
Potential Meters
Potential meters are basically electrometers which have extremely high input resistances in order to keep the feeding reference electrode free of load. This is necessary to maintain the true potential. pH - meters can be used as potential meters when fast reading is not required, because common pH meters are very slow. When the potential answer to current pulses is to be followed, potential meters are essential.
-
product
Closed Loop Hall AC/DC Current Sensor
CYHCS-SH
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can beused for measurement of DC and AC current, pulse currents etc. The output of thetransducer reflects the real wave of the current carrying conductor.
-
product
NI-9470, 5 VDC to 30 VDC, 8-Channel (Sourcing Output), 2 kHz C Series Digital Module
787089-02
5 VDC to 30 VDC, 8-Channel (Sourcing Output), 2 kHz C Series Digital Module - The NI‑9470 is a digital output module that features proportional valve drive control. You can use the NI-9470 to perform pulse width modulation (PWM), dither control, and current readback. The NI‑9470 features eight output channels compatible with signals from 5 V to 30 V and transient overvoltage protection between the output channels and the backplane.
-
product
Proximity
Proximity detection sensors measure reflected infrared (IR) energy to detect the presence of an object or person. The devices include an integrated LED driver and, in some devices, an integrated LED. The proximity detection devices provide four programmable LED drive currents and IR pulse repetitions. The proximity detection circuitry compensates for ambient light, allowing it to operate in environments ranging from bright sunlight to dark rooms. The wide dynamic range allows operation in short-distance detection applications behind dark glass, such as mobile phones. Proximity detection sensors can be used to replace a mechanical switch or to sense human gestures.
-
product
High-Speed Precision SMU (100 FA, 60 V, 1 MSa/s)
PZ2120A
The Keysight PZ2120A is a cost-effective, high-speed precision source / measure unit (SMU) featuring best-in-class narrow pulse width, fast Digitizer Mode, and seamless current measurement ranging. It enables narrow-pulsed measurements and fast dynamic measurements with a wide dynamic range for a wide range of emerging applications such as vertical-cavity surface-emitting laser (VCSEL) optical devices and integrated circuit (IC) testing. In addition, its low measurement noise performance enables measurements with shorter aperture times, and its seamless current measurement ranging function enables a wide dynamic range and eliminates range change time, which improves test throughput.
-
product
Rogowski Coil Current ProbesTOP
*Switching current waveform and pulse response characteristics of power devices*Current measurements of inverter system*AC current measurements (at large DC offset)*Impulse high current measurements*Bus Bar high current measurements
-
product
Compact Automatic Voltage Regulating Relay With Built- In TPI
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.
-
product
High Voltage Film Capacitor
STHVF
We manufacture High Voltage Film Capacitors for wide variety of High Voltage power applications with different rated Capacitances, Voltages, Discharge Energy, dv/dt, Pulse Discharge Currents, RMS Currents, Frequency ranges, size restriction, temperature ranges and even capacitor configurations.Different applications can have very different capacitor electrical and mechanical profile requirements.Please feel free to send your application details for a suggestion and quotation.
-
product
HIGH VOLTAGE SCR CONTROLLED POWER SUPPLY
xPS Series
High Voltage SCR Controlled Power Supply, P/N 18278PS Power Rating: 350 KW. Input: 480 VAC, 3 PH, 60 Hz Output: 0 to 5000 VDC, 70 Amps max Ripple: 2 % approximately at maximum rated voltage Configuration: 12 pulse externally SCR controlled rectifier system Protection Devices: Input contactors Overload relay shutoff Input surge suppressor Thermal switches Output current limiting resistor (made with 5 Ohm Kanthal heating element) Emergency power shutoff Cooling: Each 6 pulse rectifier assembly is cooled by three 10” fans Interface: 4/20 ma converter interface for output voltage and output current to SCR controller. Enclosure: The overall dimension of the unit is (78”H x 38”W x 53”D). It is comprised of two separate enclosures each with dimensions of (78” H x 38” W x 26” D) which are integrated together to form a single enclosure. Each half enclosure has one 6 pulse transformer and one 6 pulse high voltage rectifier. Weight: Approx. 5000 lbs. SCR Controller: The 12 pulse SCR controller is supplied by the customer. We were responsible for the 12 pulses Transformer and 12 pulses Rectifier section. Portability: Unit can be lifted up with a fork lift. It can also be moved around with a 5000 lb pallet jack. Transformer: Two 200 KVA transformers are used to step 480 VAC to 3750 VAC each in a 12 pulse configuration Rectifiers: Two 6 pulse rectifier assemblies capable for 5000 VDC and 60 Amps output were used. The high voltage rectifier assemblies are isolated and protected in a fiberglass plenum within the enclosure. Blocking Diode: Each diode of the 6 pulse rectifier consists of 10 diodes in series to offer a blocking voltage of 12000 V (PIV)
-
product
Frequency to Current Converter
DAT4540R
The Frequency to Current converter DAT4540R is a signal conditioning din rail mount converter which converts a pulse input to an analog output equal to the set range which is selectable from 0.1 Hz up to 20 KHz. The DAT4540R also provides 2 relay outputs and a transistor output. The input can be from a Tacho, TTL, PNP transistor or from any Namur standard. The DAT4540R provides a Voltage or Current output that is isolated from the power supply and input.
-
product
Module Testing Station
QuickSun® 550CE
QuickSun 550CE is certified by TÜV Rheinland and a detailed test report is included with every simulator proving Class A+A+A+ performance with respect to spectrum, irradiance non-uniformity and short term instability (STI). Long term instability (LTI) is also within Class A+ tolerances during the 40 ms long flash pulse. IV characteristics are recorded with an electronic load and proprietary electronics unit which measures voltage, current and irradiance signals when module is swept e.g. from short circuit to open circuit or vice versa.
-
product
Surge Generators
Hybrid
Surge pulses occur due to direct or indirect lightning strikes in a circuit or by switching transients caused by switching inductive loads or short circuits. This leads to currents or electromagnetic fields causing high voltage or current transients. Surge voltages and currents can reach several thousands of volts and thousands of amperes. Our following Surge generators simulate these disturbances for all the necessary level in accordance with IEC / EN 61000-4-5 and IEC / EN 60060.
-
product
Coupling Decoupling Network for Communication Lines
CDN61000-5C
• Application Range: ≤4kV, 1.2/50us pulse, 8 wire unshielded twisted pair (UTP) • Test Voltage: Max 4KV, 2 kV (1.2/50 µs pulse when RJ45 connector is connected. Maximum test voltage is 1.5kV when RJ45 female is unconnected or auxiliary terminal is not protected.) • Coupling mode: 90V gas- discharge tube+250ohm Resistor/Each Wire, 8 Wires Simultaneously-Ground (Common Mode) • Input and output interface: RJ45 connector • Terminal layout (RJ45 connector): First pair of lines: pins 1/2 Second pair of lines: pins3/6 Third pair of lines: pins 4/5 Fourth pair of lines: pins 7/8 • Max. operating speed: 1000MBit/s • Max operating voltage: Max 50V DC • Max operating current: Max 1A Related Instruments
-
product
Rebar Locator
Profometer PM-600
Profometer PM-600 is an advanced cover meter for the precise and non destructive measurement of concrete cover and rebar diameters and the detection of rebar locations using the eddy current principle with pulse induction as the measuring method.
-
product
Automatic Voltage Regulating Relay- Standard Model
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.
-
product
30 Amps, 50 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse
CP030
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
product
Magnetizer
412B
The Model 412B magnetizer provides many of the features of the Oersted Technology 300-series magnetizers in a small benchtop cabinet. This unit is designed for magnetizing parts which require lower energy levels due to their size or the magnetic material used. Like the 300-series magnetizers, the 412B is an ECS magnetizer, which allows the user to electronically vary the capacitance of the unit. The capacitor banks are internally discharged through a safety circuit in case of power failure or accidental power-down. When the 412B is connected to a properly equipped fixture, the front-panels can be inhibited through an overtemperature interlock circuit, preventing the magnetizer from being operated once the fixture begins to overheat. An external output is also provided for monitoring the magnetizing current pulse with an oscilliscope.
-
product
Pulse Rate to 4-20mA or Voltage Converter
SY020
The SY020 Pulse Rate Converter can be linked to any frequency generating device e.g. flow meters, which gives TTL, pulse Reed switch or coil output, converting the frequency to an analogue signal. This can be 4-20mA loop current or a voltage output. The 4-20mA version unit is loop powered.
-
product
30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP030B
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
product
Deskew Calibration Source for CP030, CP030A, CP031, CP031A, AP015, CP150, CP500
DCS025
The DCS025 Deskew Calibration Source generates time-aligned voltage and current pulses for precise deskew of voltage and current probes.This is critical for measurements in which small propagation delay differences between probes can have a large impact on a calculated measurement, e.g., instantaneous power semiconductor device loss measurements.
-
product
DIP LED Aging Tester
LS6100
Designed to measure the aging-life and color comparisons of 260pcs DIP LED. • 260 separate constant current supply • Aging functions: constant current, impact pulse, on-off mode • Range of forward voltage(VF): 5.0V • Range of forward current(IF): 1) constant current: 0-100.0mA 2) Impact pulse: 0-200.0mA • Range of impact pulse frequency: 10-9999Hz; Duty ratio: 1%-99% • Range of on-off circle: 0-9999H59M59S • Range of on-off times: 0-9999times • Range of aging time: 0-9999H59M59S