Pulse Current
-
Product
Current Measurement Board
MS 1814
-
*Maximum DC Voltage Rating: 15V to 75V*Maximum DC Current: 5A*Output Voltage per 1A: 1V*Maximum AC Current: 5A*Operating Temperature: 0°C to 55°C*Storage Temperature: -20°C to +65°C*90% Relative Humidity (Non-condensing)*No. of DC Current Channels: 9*No. of AC Current Channels: 4nos*Maximum AC Voltage Rating: 230VAC*Channel Selection: Through 16 CH Analog MUX*Measurement Error Over Full Temperature Range: 5%*Type of Output: Proportional voltages*Maximum Voltage Drop across Series Resistor Full Scale Measurement: 0.05VDC
-
Product
AC Current Transformers
-
CR Magnetics supplies an extensive line of toroidal current transformers for any need. Our offerings include measuring from 10,000 amps to a few milliamps. This includes ANSI, Commercial, Ground Fault, High Frequency, Wound Primary, DC Immune and Nano Alloy current transformers.
-
Product
Current Clamps and Sensors
-
Are designed for measuring leakage current diverted towards the earth. It enables the fault to be located or anticipated without disconnecting the equipment linked. It is specially designed to detect low fault currentson power circuits.
-
Product
Current Transformer Analyzer/Tester
GF1061
-
Beijing GFUVE Electronics Co.,Ltd.
Portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to download data or RS232 port to PC control. This model GF1061 CT PT analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE C57.13 and IEC60044 & IEC61869 standards.
-
Product
Current Transformer
ST-30RCT
-
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 1600~4000
-
Product
Current Transformers
-
The Institute of Electrical and Electronic Engineers defines a current transformer (IEEE Std C57.13) as “a transformer intended to reproduce in its secondary circuit, in a definite and known proportion, the current of its primary circuit with the phase relations substantially preserved”. Its primary winding is connected in series with the conductor carrying the current to be measured or to be controlled and its secondary winding is connected to the measuring, protection or control devices. Osborne designs and manufactures current transformers which are used for instrumentation applications, others which are used for power system synchronizing applications and others which are used in protection circuit application. They have been designed to meet specified current ratios, burden impedance and transformation errors.
-
Product
High-Power Low-Loss Pulsed Bias Tees
MBT series
-
The MBT-series of bias tees is based on Maury's patented broadband capacitor (US Patent 9,614,267) which simultaneously enables the industry's widest bandwidth, lowest insertion loss and lowest return loss in a coaxial bias tee up to 18 GHz. In addition, its unique design makes it ideal for pulsed applications, including pulsed IV and pulsed load pull characterization, without distorting the voltage and current waveforms.
-
Product
Current Tester
MIG0624
-
The MIG0624 current tester is designed to test surge protection devices for low voltage applications (<1000 V). MIG0624 is a current generator delivering a 8/20 µs impulse up to 24kA. The exact waveform delivered is a function of the surge generator and the impedance to which the surge is applied.
-
Product
Pulsed X-ray technology
-
Golden Engineering X-ray generators are based on Pulsed X-ray technology. Pulsed X-rays generate a high intensity X-ray burst (pulse) in a very short period of time (10 to 50 nanoseconds depending on the model). The output dose of each pulse is 3-6 mR measured 12 inches from the front of the X-ray generator. The operator varies the overall dose of each exposure by changing the pulse setting. The pulse rate varies from 10 pulses per second to 25 pulses per second depending on the model. The generators can fire up to 200 pulses before a four-minute rest period.
-
Product
Pulse Generators
-
Active Technologies Pulse Generators can be used to set up continuous or triggered pulse streams and offers flexibility to address the most challenging applications like big physics, automated testing, microwaves, modulators, wireless communication, medical and chemistry.
-
Product
Current Recorders
-
A range of Low Cost Voltage, Current and Energy Recorders (Analysers, Analyzers) allows users to check loading and voltage performance, as well as Power and Energy surveys. A great replacement for a Hawk 5000 Meter.
-
Product
Standard - 1.44 (41.00 - 4.50 (128.00) High Current Probe
HCP-13H
-
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Current to Digital
-
Analog Devices’ breakthrough current-to-digital converter technology is backed by award winning expertise to help solve your medical, industrial, and security application needs. Our high speed, high resolution ADC modules enable improved CT scanner data acquisition, photodiode sensors and power monitoring, spectroscopy, and high channel count data acquisition systems.
-
Product
Current Preamplifier
1641
-
The Model 1641 Current Preamplifier is a simple low cost wideband gain block for use with photomultipliers
-
Product
Burden Set – Current
BSC-102
-
The industry has recognized the actual load (burden) on CTs is lower than the standard ANSI burdens allow. So a new IEEE Specification (IEEE C57.13.6) accommodates that fact by introducing two new burdens and two new accuracy classes. This new specification address “High Accuracy”CTs.
-
Product
150 Amps, 10 MHz BW Current Probe - AC/DC , 500 Amp Peak Pulse
CP150
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Square Lenticular Pulsed Backlight
ViTech B108
-
Lensed illumination is intended for pulsed illumination of objects in machine vision systems, in which it is not possible to mount an additional light source close to the object or where it is necessary to create the required glow intensity in a certain area. A distinctive feature of the B108 modules is the absence of persistence (except for the version with white LEDs).
-
Product
Pulse & Delay Generators
-
Berkeley Nucleonics Corporation
Provides high frequency pulses, delays and bursts. It is an ideal testing and timing control instrument for electronics, lasers or camera setup.
-
Product
Pulse Generator
Digital Ring Kits
-
NEMA C frame rings provide mounting for 1101, 1201, and 1202 shaft speed sensors for use with 199SM magnet wheels on motors with NEMA C frames. The DRK (Digital Ring Kit) Series provides a single-channel output and the QDRK (Quadrature Digital Ring Kit) Series offers a bi-directional output. Kits include mounting ring, hardware, magnet wheel, and sensor.
-
Product
Video Pulse Generator
MS 1811
-
*4 Channels of Variable Pulse / Amplitude Output*Pulse Generation Delay between any Two Channels can be Programmable between 2ns to 1ms*Pulse Width can be programmed from 20ns to 268ms (Range: 60ns � 2Sec, Resolution: 2ns, Accuracy: �5ns)*Programmable Pulse PRI (Range: 0ns � 2Sec, Resolution: 10ns, Accuracy: �5ns)*Delay Amongst Channels (Range: 0 � 1.34S, Resolution: 2ns, Accuracy: �5ns)*Rise Time and Fall time is less than 5ns (Programmable Slew Rate 2ns to 10ns � Optional)*Pulse Amplitude can be Programmed between 50mV to 6V (Range: 0 � 6V, Resolution: 10mV)*Channels can be terminated with different loads (50W,75W and 90W)*Standard ISA Bus Interface*Clock (Frequency: 100MHz, Source: Internal/External)*Driver interface for Windows2000/XP/VISTA and LINUX OS
-
Product
HyMPulse Pulsed Field Magnetometer
-
Metis Instruments & Equipment NV
Geometry independent M-measurement (patent pending): One probe fits all, no pole shoes per magnet geometry. Measure the actual magnet instead of a prepared standard size sample. Measurement of industrial shapes like segments, cylinders, bricks,... with one probe
-
Product
System Tests Radar Pulse Stability
PN9002
-
Noise eXtended Technologies S.A.S.
The cost-effective PN9002 test simplifies the testing and analysis of pulse-to-pulse amplitude and phase stability for radar systems and components to 18GHz.
-
Product
Current Probe
PA-659
-
*Maximum Current Value: +/- 150ADC, 100A RMS*1mA = 5mA, 50mA (switchable)*Rising Time: 0.7uS*Bandwidth: DC ~ 500kHz*Over Range Indicator*Battery, AC Power Supply Adaptor (free), dual usages
-
Product
10 Digit Rate/Batch Counter (Pulse)
CS2-TM-Pulse
-
The CS2-TM(Pulse Input) is innovation totalizer.Adtek builds in high technology with wide input range from 0.01Hz~ 140.00KHz with auto-range function at same unit. There are three setting modes for K factor, 1/K factor and flow speed to match the difference output description of flow-meters.The Totalizer provides high accuracy measurement, display, control and communication (Modbus RTU mode) of Pulse from Flowmeter or encoder, proximity switch, photo switch for length control.There are two display screen and 3 external control input (DI) in standard and the optional 4 Relay, 1 Analogue, 1 Pulse and RS485 port available. They are also support fantastic control function as like as N, R, C mode for totalizer and batch control.
-
Product
Residual Current Protection
-
Solutions to ensure the safety of people and installations against any ground currents. Available with ultra-immunized system as an essential solution to avoid financial losses due to outages caused by inadvertent trips. Specially designed to protect industrial installations in AC networks (type A), installations with both AC and DC components and DC-only installations (type B). Available with RS-485 communications (Modbus RTU) and remote control inputs/outputs.
-
Product
Current Transformer
ST-3RCT
-
Standard Electric Works Co., Ltd
● Primary Current Rating (Amp) : 20~300
-
Product
Eddy Current Dynamometers
WT Dyno
-
Our WT series eddy current dynamometers are mainly used in the development and testing of all types of prime mover, as well as various engine assemblies. Due to their robust design, which incorporates improved control characteristics, they can be used both as steady state and as transient test stands.Their high speeds for automobile engine testing and their optimised cooling chamber, are convincing arguments that speak for themselves. All WT type dynamometers are suitable for operation in both directions of rotation.
-
Product
Pulse Modulator IM-20
-
*Wide Frequency Range: 10 MHz...20 GHz*High Pause Power Mitigation: ≥ 70 dB*Signal Radio Impulse < 10 ns*Parallel Data Input*Input/Output Modulator Ports
-
Product
Hydraulic Pulse Fatigue Testing System
PFT-500
-
Jinan Testing Equipment IE Corporation
PFT-500 hydraulic pulse fatigue testing machine is mainly applicableto large size parts such as bridges, trusses, automotive chassis, front and rear axels, locomotive frames, chassis and various concrete structures for static compression test and dynamic unidirectional pulse fatigue tests. The Fatigue Testing System for Rail has significant characteristics of reliable design, simple operation, energy conservation, and low operation cost etc.





























