Product
LXI Microwave Multiplexer, 50Ω 6-Channel 14-Bank 40GHz SMA-2.9
60-801-414
-
The 60-801-414 is a 6-channel, 14-bank RF multiplexer suitable for switching 50Ω signals up to 40GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI-2503 , 48‐Channel, 1-, 2-, or 4-Wire, Electromechanical PXI Multiplexer Switch Module
777697-01
-
48‐Channel, 1-, 2-, or 4-Wire, Electromechanical PXI Multiplexer Switch Module—The PXI‑2503 is a PXI switch module that you can configure as a multiplexer or matrix switch by using different terminal block accessories. It uses electromechanical relays with low thermal offset for accurate measurements and offers a 1,024‐step scan list for deterministic scanning.
-
Product
PXI Dual 4 to 1 RF Multiplexer 3GHz 50 Ohm MCX
40-872-102
-
The 40-872-102 is a 50 Ohm 4 to 1 RF MUX with 2 banks in a single PXI slot. It exhibits low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The injection of noise and unwanted signals into the signal paths of the 40-872 has been minimized by careful attention to the mechanical and electrical design.
-
Product
PCI 2 Amp Multiplexer, Single 32-Channel, 1-Pole
50-635A-101
-
The 50-635A-101 is a single 32-channel, 1-pole MUX and is part of a range of PCI Multiplexer cards available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe High Density 2A Multiplexer, 26-Bank, 4-Channel, 1-Pole
40-614D-023
-
The 40-614D-023 (PXI) and 42-614D-023 (PXIe) 26-bank, 4-channel, 1-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI 2A Multiplexer, 1-Bank, 4-Channel, 32-Pole
40-614B-020
-
This 1-bank, 4-channel, 32-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
LXI Microwave Multiplexer, SP4T, 14-Bank, 26.5GHz, 50Ω, SMA
60-803-314
-
Our 60-803-314 is a 14 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 26.5GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 50/125 Fiber, LC Connectors
42-852A-418-M50
-
The 40/42-852A-418-M50 is a PXI/PXIe 8-channel multiplexer with LC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI High Density MUX BRIC, 48-Chan, 10-Pole
40-570-413
-
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 40GHz, 50Ω, SMA-2.9, Remote Mount
40-784B-042-E
-
The 40-784B-042-E (PXI) and 42-784B-042-E (PXIe) are dual SP6T 40GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP12T, 8 GHz, 50 Ω, N-Type, Remote Mount, Failsafe
42-788-211-E
-
The 40-788-211-E (PXI) and 42-788-211-E (PXIe) are single failsafe SP12T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
PXI High Density Mux 99 Channel 1 pole
40-670A-021-99/1
-
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PXI Very High Density Mux 99 Ch 2 Pole
40-670A-022-99/2
-
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PCI 2 Amp Multiplexer, Single 64-Channel, 1-Pole
50-635A-001
-
The 50-635A-001 is a single 64-channel, 1-pole MUX and is part of a range of PCI Multiplexer cards available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 50/125 Fiber, SC/PC Connectors
42-852A-218-M50
-
The 40/42-852A-218-M50 is a PXI/PXIe 8-channel multiplexer with SC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 5-Bank 18GHz SMA
60-801-205
-
The 60-801-205 is a 6-channel, 5-bank RF multiplexer suitable for switching 50Ω signals up to 18GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI/PXIe High Density 2A Multiplexer, 2-Bank, 16-Channel, 4-Pole
40-614D-012
-
The 40-614D-012 (PXI) and 42-614D-012 (PXIe) 2-bank, 16-channel, 4-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe RF Multiplexer, Dual 4-Channel, 3GHz, 75Ω, SMB
40-832A-002
-
The 40-832A-002 (PXI) and 42-832A-002 (PXIe) are 75 Ohm 4 to 1 RF multiplexers with 2 banks in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
PXI/PXIe RF Multiplexer, Quad 4-Channel, Terminated Common, 3GHz, 50Ω, SMB
40-876A-004
-
The 40-876A-004 (PXI) and 42-876A-004 (PXIe) are 50 Ohm 4 to 1 RF multiplexers with 4 banks in a single slot. Additionally, extra switching allows the common connection to be terminated into 50 Ohm, maintaining signal integrity. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
Product
PXI Multiplexer, Single 16-Channel, 4-Pole
40-630A-022-16/4
-
The 40-630A-022-16/4 is a single 16-channel, 4-pole PXI multiplexer and is part of our series of general purpose multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI High Density Multiplexer, 5-Bank, 16-Channel, 2-Pole
40-615A-006
-
The 40-615A-006 is a 5-bank, 16-channel, 2-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
Product
LXI Microwave Multiplexer, SP4T, 7-Bank, 26.5GHz, 50Ω, SMA
60-803-307
-
Our 60-803-307 is a 7 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 26.5GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI Very High Density Multiplexer, 10-Channel, 16-pole
40-670C-022-10/16
-
The 40-670C-022-10/16 is a 10-channel, 16-pole MUX and is part of a series of very high density multiplexer modules featuring a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
Product
PXI 2A Multiplexer, 1-Bank, 16-Channel, 8-Pole
40-614B-018
-
This 1-bank, 16-channel, 8-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI Dual 12:1 High Voltage Power MUX
40-331-002
-
The Pickering Interfaces 40-331/332 High Voltage Power Multiplexer and Matrix Modules are suitable for applications requiring high voltage power relay switching with high density. They feature current handling up to 5A, 1000VDC/1000VDC peak cold switching and 110VDC/250VAC hot switching. The 40-331 is available as a single 24:1, dual 12:1, quad 6:1, hex 4:1, octal 3:1 or twelve 2:1 multiplexer, and the 40-332 is available in 12x2 or 6x4 matrix configurations. Connections are made via a front panel mounted 37 pin high voltage D-Type connector.
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 62.5/125 Fiber, FC/PC Connectors, With Interlock
42-852A-118-M62.5-HI
-
The 40/42-852A-118-M62.5-HI is a PXI/PXIe 8-channel multiplexer with FC/PC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 26.5GHz, 50Ω, SMA, Remote Mount
40-784B-032-E
-
The 40-784B-032-E (PXI) and 42-784B-032-E (PXIe) are dual SP6T 26.5GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI/PXIe MEMS Optical Switch, Dual Insert/Bypass
40-860A-222
-
The 40/42-860A-222 is a PXI/PXIe dual insert/bypass switch with SC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
PXI 2 Amp Multiplexer, Single 64-Channel, 1-Pole
40-635A-001
-
The 40-635A-001 is a single 64-channel, 1-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
Dual 4-Channel 1-Pole 16 Amp PXI Power Multiplexer
40-662-012
-
The 40-662 range of 16 Amp PXI power multiplexer modules is available in seven configurations ranging from 4-off 2:1 multiplexers to 1-off 16:1 multiplexer. Power multiplexer modules are intended for switching heavy AC or DC loads or for the slave switching of large external relays, contactors and solenoids. All versions are suitable for switching loads up to 16 Amp at 250VAC. User connections are made via a 20-way GMCT plug which is fully support by our comprehensive range of cables and connector accessories.