CAT
Computer Aided Test
-
product
PXIe-4300, 16-Bit, 8-Channel, 250 kS/s, 300 V, Ch-Ch Isolated PXI Analog Input Module
781337-01
16-Bit, 8-Channel, 250 kS/s, 300 V, Ch-Ch Isolated PXI Analog Input Module—The PXIe‑4300 provides integrated data acquisition and signal conditioning for high-voltage measurements. It provides increased accuracy, simultaneous sampling, and synchronization features for scalable measurement systems. The PXIe‑4300 includes 300 Vrms channel‑to‑channel CAT II isolation and 3,300 Vrms channel‑to‑earth 5 second withstand isolation to protect users and equipment from hazardous voltages. This module offers programmable lowpass filtering, DC input coupling, and two PFI lines for digital input triggering. The included NI‑DAQmx driver simplifies hardware and configuration and measurement.
-
product
Digital Tank Test Kit
4109
The voltmeter included in the kit, the “Model DPM” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers two ranges, ±2VDC and ±20VDC with a 20MΩ input impedance. Since the voltmeter is digital [in contrast to the meter in our analog tank test kit (Cat. # 4108)], both negative and positive voltages are displayed. `
-
product
230V AC Socket Tester With RCD Test (For UK)
1944
Peaceful Thriving Enterprise Co Ltd
*With UKCA Approval.*Test for 230VAC circuits.*Neon indicators.*RCD Test.*30mA leakage current measurement.*Detect faulty wiring status in 3 wire receptacle.*Various combinations of 3 neon idnicators tell if wiring is OK or 6 possible faulty conditions.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 1.5W*Frequency: 50Hz
-
product
High Voltage Probe
CP-3308R
*100:1 scope probe *300MHz Bandwidth *Read out Function *Division Ratio x 100 *100MΩ Fix Input Impedance *1500V DC Working Voltage (CAT Ⅱ) *2000V AC peak to peak MAX. (CAT Ⅰ) *CE Approved.
-
product
Handheld Circuit Breaker And Timer Analyser
CAT-H Series
The operation of the breaker can be initiated in different ways (e.g. from a control room, by a local breaker or externally by a test device) depending on the test conditions. Various time measurement triggers are available to record a measurement under a different test condition:*Coil control channel*Continuous current clamping channel*DC voltage channel
-
product
Clamp Meter, Auto, True RMS, 400 A AC, 600 V AC, 600 V DC, 28 mm Jaw Opening Max.
72-7226 CAL D
The 72-7226 CAL D from Tenma is a digital clamp meter. This stable, safe and reliable digital clamp multimeter is designed with large scale integrated circuits and A/D converter as the core as well as overload protection and novel structure which make them a superb tool for electricians. It measures AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, diodes and continuity and also includes data hold, sleep mode and relative mode features. The resistance measurement range from 400 ohm/4kohm/40Kohm/400Kohm/4Mohm/40Mohm (±(1%+2)), frequency measurement range from 10Hz to 10MHz (±(0.1%+3) accuracy). It is 3 3/4 digit digital clamp meter with precise operation, fashionable structure and highly reliable measuring instrument. The meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. It complies with IEC61010, pollution degree 2, overvoltage category (CAT II 600V, CAT III 300V) and double insulation.
-
product
Test Probe Leads, With 19-mm Tips And 4-mm Tips
U1169A
The U1169A consists of one pair (red and black) of insulated test leads, one pair of test probes with 19-mm tips and another pair of test probes with 4-mm tips. Recommended for use with Keysight handheld digital multimeters. Rated at CAT III 1000V, CAT IV 600V, 15A.
-
product
High Voltage Probe
HVP-40DM
*DC 40KV CAT II Pollution 2.*2000MΩ Impedance.*3999 LCD display.*Accuracy 1.0% full range.*T.C. 100 ppm/oC*400V/4KV/40KV, 3 range.*Resolution 0.1V/1V/10V.*PEAK HOLD, Auto power off.*CE, TUV GS, UL, CUL, IEC1010
-
product
NI-9209, ±10 V, 500 S/s, 16-Channel C Series Voltage Input Module
783729-01
±10 V, 500 S/s, 16-Channel C Series Voltage Input Module - The NI‑9209 performs single-ended or differential analog input. This module provides 60 VDC CAT I isolation and built-in 50/60 Hz filtering, making it a valuable addition to industrial measurement systems.
-
product
Fuel Injection Pressure Tester Bleed-Off Kit
37400
Adds a bleed-off feature to our Cat. Nos. 33770, 33800, 33865, 33900, 33950, 33980, 53770, 53900, 53950, 53980, (This feature is included with Cat. Nos. 36200, 36250, 38000, 53800, 53865, 56200, 56250 & 58000 ).
-
product
Ultimate AC Sensor
Our Ultimate AC Sensor is just that... the Ultimate in voltage detection. This sensor detects 50-1000 volts AC and features a visual and audio alert. Like all of our sensors, it does not react to static electricity and is designed for a CAT IV environment.
-
product
Differential Probe
DP-8V
*MAX. Input Voltage: ±4KV DC or 8KV p-p or AC 2.8KV rms*Bandwidth: DC-50MHz*Input Impedance 20MΩ// 2PF*x10, x100, x1000 Attenuator*To Ground MAX. Voltage: 4KV CAT III*Output Impedance 50Ω
-
product
DIGITAL MULTIMETER, MEAN VALUE, 10A, 1KV
72-13580
*Digital multimeter with 6000 counts display*CAT III 1000V, CAT IV 600V safety rating*Manual function select and auto ranging*LCD backlight and 0.1% to 99.9% duty cycle*Data hold, max/min/relative modes*61 segments analogue bar graph*RS232 interface*Input protection*Powered by 9V (6F22) battery*12-month limited warranty *view Terms & Conditions for details
-
product
CB-37F-HVD, 37-pin ScrewTerminal Blk, UL rec.150V CAT II, Din Rail
779491-01
37-Pin Female D-SUB to 37-Pin Female Screw Terminal, High Voltage Horizontal DIN Rail Terminal Block - The CB-37F-HVD features screw terminal connectivity for up to 37 I/O signals, 12 to 30 AWG. It has a female 37-pin D-SUB connector for connectivity to C Series I/O Modules and … data acquisition devices. The CB-37F-VHD is UL recognized. You can use the CB-37F-VHD with low-voltage or high-voltage products up to 150 V.
-
product
Clamp Meter, True RMS, 100 A AC, 600 V AC, 600 V DC, 17 mm Jaw Opening Max.
72-2985
The 72-2985 from Tenma is a mini clamp meter in orange and grey colour. It features high reliability, safety precision and compact design. Its resolution ratio is 1mA, maximum range has maximum range of 100A AC/DC, particular VFC start mode. Entering this mode can accurately measure voltage and current which has VFC frequency conversion. Voltage or current response display is true valid value. Whole range overload protection, reliable measurement accuracy and unique appearance design makes it an outstanding new generation functional electrician/electric power measurement instrument. This complies with EN 610101-1, 61010-2-032, 61010-2-033, pollution degree 2, measurement category: (CAT II 600V, CAT III 300V) and double insulation standards. Conforms to UL STD. 61010-1, 61010-2-032, 61010-2-33 certified to CSA STD. C22.2 NO. 61010-1, IEC STD 61010-2-032, 61010-2-033.
-
product
Test Lead Set
131139
IEC 1010 Rating: 1000 Volts Cat III Double/Reinforced Insulation 20Amps. Kit Comprises:- 1 Pair 123856/OF-OR/1.2 Double Insulated Silicone Lead Assemblies. 1 Pair 121017 Test Prods. 1 Pair 121026 Sprung Hooks. 1 Pair 126024 Fully Insulated Crocodile Clips. Packed In Silver Wallet.
-
product
Testing Large Radar Sensors with CATR Technology
CATR Radar Test System UTP 5069
Modern driver assistance systems must recognize increasingly complex traffic scenarios and convert them into appropriate vehicle reactions with the help of artificial intelligence (AI) and specific algorithms. Imaging radar sensors with a higher spatial resolution, so-called imaging radar sensors, are therefore required. These can better distinguish larger from smaller objects and, due to the larger antenna apertures, also require larger dimensions of the test environment or larger far-field distances. Testing these sensors in the direct far field ( UTP 5065 ) would therefore require very large absorber chambers up to ten meters in size and more.Our efficient test system UTP 5069 offers exactly the right solution:By using CATR technology (Compact Antenna Test Range), 4D, imaging and other radar sensors with large far-field distances are calibrated with high precision in a small footprint. With the extremely low-reflection NOFFZ absorber chamber, the system is very well suited not only for validation, but also for EOL tests.
-
product
USB-6216, Isolated 16 AI (16-Bit, 400 kS/s), 2 AO (250 kS/s), up to 32 DIO USB Multifunction I/O Device
780170-01
Isolated 16 AI (16-Bit, 400 kS/s), 2 AO (250 kS/s), up to 32 DIO USB Multifunction I/O Device - The USB‑6216 is an isolated, multifunction DAQ device. It offers analog I/O, digital I/O, and two 32‑bit counters. For improved accuracy and safety, the USB‑6216 provides 60 V, CAT I isolation. It also features signal streaming technology that gives you DMA-like bidirectional high-speed streaming of data across USB. The device is ideal for test, control, and design applications including portable data logging, field monitoring, embedded OEM, in-vehicle data acquisition, and academic. The USB‑6216 features a lightweight mechanical enclosure and is bus powered for easy portability. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
product
Magnet Testing
m-cat
m-cat is a magnetic field mapper for magnetrons which measures the magnetic stray field data of magnetrons on all three spatial axes and also calculates geometric data. This allows sputtering processes to be monitored and optimized, since the setting or status of the magnetron is critical to the subsequent outcome of the coating process.
-
product
Synchroscope
LS-96A SYNC
Standard Electric Works Co., Ltd
● Input voltage: 110V AC, 120V AC, 220V AC, 230V AC or 240V AC.● Square shape panel 96 x 96mm● 360° indication● PC window, ABS resin frame, PC case● Safety standard: IEC/EN 61010-1 CAT III 300V EN 61326-1
-
product
High Voltage Probe
HVP-40
*MAX. Voltage : DC : 40KV, AC : 28KV, (50/60Hz only) CAT II.*1000MΩ Input Impedance.*Accuracy **DC: ± 1% to 20KV. ± 2% to 40KV. **AC: -5% to -10% (50/60Hz)*Division Ration : 1000:1*CE, TUV GS, UL, CUL, IEC1010
-
product
Product Design and Experience
Catia
CATIA delivers the unique ability not only to model any product, but to do so in the context of its real-life behavior: design in the age of experience. Systems architects, engineers, designers and all contributors can define, imagine and shape the connected world.
-
product
Bench-top Microreactor & Combined Mass Spectrometer System
CATLAB-PCS
The Hiden CATLAB is a bench-top microreactor and combined mass spectrometer system for rapid and reproducible catalyst characterisation and reaction studies. The modular benchtop system features an advanced fast-response low thermal mass 1000oC furnace, multistream gas flow control of up to eight integrated gas streams, together with the precision Hiden quadrupole gas analyser.
-
product
*Micro-fluoroscopic X-ray Inspection System
Cath-X
The Cath-X is a bench top system employing Glenbrook’s micro-fluoroscopy technology providing highly detailed x-ray video of the critical components of the needle device. The transparent, safely shielded, view chamber permits the operator to locate the critical areas of the needle for inspection. The x-ray image can be further magnified using the electro-optical zoom feature of the Cath-X.
-
product
Catalytic Ozone Destructs
CAT-O3 Series
Teledyne Advanced Pollution Instrumentation
The CAT-O3 series of ozone destructs safely decompose high concentrations of ozone gas to sub-ppm levels that are below recommended ozone safety limits. The catalytic method of decomposition uses a metal oxide catalyst to passively convert the ozone to oxygen.
-
product
Handheld Oscilloscopes, 100 MHz, 2 Analog Channels
U1610A
100 MHz2 analog channelsTroubleshoot in any weather with channel-to-channel isolation and a CAT III 600 V safety ratingIdentify glitches easily with dual window zoomView subtle signal details more clearly with up to 1 Gsa/s sampling rate and 120 Kpts memoryDebug under any lighting conditions with 3 selectable viewing modes (indoor, outdoor and night vision)Get 3 instruments in 1: a dual-channel oscilloscope, built-in DMM and data loggerEasier start-up with 10 selectable languages
-
product
Compact Manual Ranging 600V Multimeter
DL9204
Compact manual ranging digital multimeter with 2000 count LCD display. Full protection on all ranges, safety category to CAT 111 600 V. Functions include battery and diode test.
-
product
MirrorLink Test System
Catena 2210
The Catena 2210 is a test tool with two USB Network Control Model ("NCM") devices. These devices create a bridge between two USB hosts. Validation testing is made possible by connecting a test control computer to the USB host being tested. Ethernet traffic from the test host is transferred through the Catena 2210 device to the control host, and vice versa.
-
product
Erbium Doped Amplifier
CATV
Amonics CATY Rackmount EDFA area made with high power pump laser and stability pump combiners, robust in high power boosting. The result are EDFAs that possess high output power, high gain with very low noise, and are ideal for CATV applications. The turnkey microprocessor controlled rackmount EDFAs manage alarms and status indicators. An integrated RS232 or Ethernet computer interface enables easy control, diagnostic functions and data acquisition.
-
product
Catena 1910 HSIC Tester
Catena 1910
The MCCI Catena 1910 HSIC USB Tester enables testing of HSIC Host or HSIC Device products. It can be used to exercise your product by operating as an active host or active device, while simultaneously capturing USB traffic for analysis. For test and validation of a final system, Passive Capture mode lets you debug and verify communication between your HSIC Host and HSIC Device,