Modbus
communications protocol for sharing data between controllers.
See Also: Communication Protocol, Near Field Communications, Data Communications, Modbus RTU
-
Product
Wi-Fi Modbus TCP Data Acquisition
-
Wi-Fi Data Acquisition modules communicate over Modbus TCP and support wireless encryption. They can easily be used with SCADA software for easy and safe access.
-
Product
Modbus Register Converter
Model 2390
-
* Converts Modbus Registers and variables for replacement Modbus devices.* Maintain existing software when upgrading Modbus systems.* Provides serial control of Modbus RTU devices from any ASCII source.* User defined Register Conversion Table supports all Modbus RTU devices.* Internal Register Conversion Tables for Watlow F4-to-EZ-ZONE and F4-to-F4T conversion.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes baud rate conversion capability.* Uses SCPI commands to load the Conversion Table and set serial settings.* Small metal case mounts on a DIN rail or on any flat panel.* 239x Table Loader Program uploads the 2390 Register Conversion Table from an Excel csv file.* 239x Serial Keyboard Program provides instant control of the 2390 and Modbus Slave Devices without writing a program.
-
Product
Economic Type Temperature Indicator
CS1-T
-
CS1-T economic type Temperature Indicator has been designed with high accuracy measurement, display and communication of Thermocouple or Pt100Ω.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of machinery and testing equipments applications.
-
Product
Free Serial-TCP (More Than Just A Device Server)
-
In the past two decades, legacy serial communication protocols such as Modbus have merged rapidly with modern TCP/IP communication, yielding benefits including widely available infrastructures and greater distance, reliability, and speed. The Serial-TCP program (more than just a Device Server) bridges your existing Serial COM port and TCP/IP without the need for changing existing protocol. It works seamlessly and transparently, just like passive RS232 / RS485 / RS422 converters, repeaters, and hubs, while the difference is that one requires installation of cables and converters with limited distance; and the other simply makes use of the existing computers and networks with an unlimited transmission distance
-
Product
OPC Server
-
An OPC sever (OLE for Process Control) provides IO and more devices to communicate with a wide range of HMI/SCADA software packages residing on a host. Advantech''s OPC server for ADAM and modbus devices features OPC DA (data access) and AE(alarm and events) client for the rapid testing.
-
Product
Industrial 4-Port Modbus Gateway
EKI-1224
-
Supports surge protection for D.C. power ports with line to line 2 KV, and line to earth 4 KV; for signal ports with 4 KV. Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy. Integration of Modbus TCP and Modbus RTU/ASCII networks.
-
Product
4 2/3 Digital Resistance Meter
CS2-RS
-
CS2-RS Resistance Indicator has been designed with high accuracy measurement, display and communication of Ohm (2 wire) as like as Coil of motor or transformer.The meter supports Field Calibration function. It can be calibrated with sensor (Resistance) to meet machinery structure.We build flexible function as like as 3 bank (for multi-range scaling and set point) and 3 external control inputs meet to various testing equipment inquiry.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments applications.
-
Product
4 2/3 Digits Voltage/Current Meter
CS2-VA
-
CS2-VA Voltage/Current Meter is designed with high accuracy measurement, display and communication of 0~600V or 0~10A for DC/AC/TMRS.● ADTEK builds flexible function as like as 3 bank (for multi-range scaling and set point) and 3 external control inputs meet to various testing equipment inquiry.They are also build in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of industrial applications.
-
Product
4 Digit Temperature Meter (5 Channels)
CM1-TX5
-
RS-485 Modbus RTU protocol (with communication LED indicator)RS-485 address 1~255Communication Baudrate 9600, 19200, 38400, 57600, 115.2KParity check N81, N82, E81, O81Input 5 channels of signal selectable:thermocouple/PT100.5 channels of input can be set to play 1~10 seconds loop display.1~5 channels of display value limits can be set, and the number of channels of carousel display screens can be set by yourself.5 channels of input signals with LED unit cycle display.Standard 2 groups of alarms Hi, LO with communication LED indicators to ensure the normal operation of the field system.Suitable for HVAC refrigeration and air conditioning PLC, DDC, PC brands to achieve remote real-time monitoringCan be used in solar panels, medical control, clean room, ice water host, boiler, motor, chemical plant, power plant, school energy-saving control, remote control of power monitoring panel
-
Product
Multi-Circuit Power Meter (DIN rail) (ADPower Series)
ADP-PM-A
-
The ADP-PM-A was designed for multi-circuit power measurement, up to 12 single phase or 4 three-phase circuit power inputs. Applicable to different types of power circuit makes ADP-PM-A a valuable option.Hardware built in 1 RS485 (Modbus) communication port, demand function, data logging and 2MB Flash memory.At the same time, din rail mounting provides easy installation and larger flexibility.
-
Product
Gas Detection System Controller
SMC Sentry IT
-
The SMC Sentry IT Controller is a powerful network-enabled hazardous gas detection system that operates up to 32 detectors and interfaces with devices over Modbus RTU, 4-20 mA, Sentry PSG Bus, and conventional dry contact. The embedded web application enables users to view important data remotely and provides connectivity into the Industrial Internet of Things (IIoT).
-
Product
4 Digit Process Meter
CM1-PR
-
CM1-PR 4 Digits Process Meter has been designed in simple function and 4 digital 20.0mm LED displays with economic cost.They are can be programmed by tact switches that are hidden in backside of front bezel.They are also available option of 2 Relay outputs, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of industrial applications.
-
Product
Signal Conditioners & Interface
-
Modbus RTU Remote Connectivity and Control. Minimize Long Cable Runs with Modbus Network. Pulse to Frequency Conversion. Shaft Speed Pulse to DeviceNet. Shaft Speed Pulse to 4-20 mA Conversion.Sensor Compatibility
-
Product
Free Modbus Device Tester Software
-
Global Multimedia Private Ltd.
This software was developed to test Information Displays made by Global Multimedia for modbus protocol compliance. It can be used to test your firmware on a serial device for Modbus RTU conformance.
-
Product
Programmable Digital Panel Meters
RS485
-
Kusam Electrical Industries Limited
• Manages sending and receiving signal of multiple Modbus RTU instruments.• Programmable address for reading data• Data form: Unsigned Int / Signed Int• Max.Baud rate: 38400• Programmable address:1 ~ 255• With alarm setting and analog output
-
Product
I/O's & Converters
-
Rishabh Instruments Pvt. Ltd.,
Module of logic outputs. Control of actuators from monitoring systems or PLC over RS485. 4 relay outputs or 8 OC outputs steered through RS-485/Modbus. Fixing on a TS35 rail. Full galvanic separation between outputs (for relay outputs). Configuration through free LPConfig software.
-
Product
5 Digit Frequency Meter
CS2-F
-
CS2-F Freqeuncy Meter is designed high accuracy measurement, display, control and communication (Modbus RTU mode) of pulse(Frequency) or AC Frequency.● The innovation feature is auto-range input from 0.01Hz~ 100KHz(~140KHz in option). The display resolution will be auto-changed to show the highest according to input frequency. They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of testing and machinery control applications. Please refer to the detail description on pages 2/33~7/33.There are not only controllers, but also an I/O interface in any system. ADtek built in difference ideal for External Control input and Relay output as like as I/O module of PLC. It’s very connivance to achieve remote monitoring and control by CS2 series.
-
Product
Economic Type Potentiometer Indicator
CS1-PM
-
CS1-PM economic type Potentiometer Indicator has been designed with high accuracy measurement, display and communication of resistance (3 wires) as like as Positioner.The meter supports Field Calibration function. It can be calibrated with sensor (Potentiometer) to meet machinery structure.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485 (Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of machinery and testing equipments applications.
-
Product
Flow Monitor
B2900
-
Blancett B2900 flow monitor offers advanced digital signal processing technology in an easy-to-access package. Enclosed in a spacious polycarbonate NEMA 4X housing, the electronics are located on a single board, designed for straightforward and convenient field installation. The B2900 enclosure features an LCD display with push button programming as well as a pre-drilled hole for external wiring connections, such as Modbus RTU and other outputs.
-
Product
4-Slot Distributed DA&C System For RS-485
ADAM-5000/485
Data Acquisition Module
RS-485 communication for easy installation and networking4 slots for up to 64 points data monitoring card control in one moduleSupports ADAM ASCII protocol or Modbus®/RTU protocolSupports Modbus/RTU protocol with user-defined Modbus addressExtensive software support, includes windows DLL drivers, OCX drivers, OPC server and popular HMI/SCADA software driversSeamlessly integrated with easy-to-use ADAMView data acquisition software
-
Product
Fieldbus Gateway
EKI-1242IEIMS
-
Modbus RTU/TCP to 3-in-1 EtherNet/IP or PROFINET or OPC UA Protocol Gateway, Wide Temperature. Seamless integrate Modbus RTU/TCP and EtherNet/IP or PROFINET or OPC UA communication. Built-in real time diagnostic to increase high efficiency of device management.
-
Product
Free Serial Port Tools
-
*The clever terminal program for serial port and field-bus communication.*Build your own sending dialogs and create customized user interfaces *Simulate field-bus telegrams *Play Modbus ASCII/RTU master with predefined Modbus function dialogs
-
Product
Modbus Slave Simulator
ModSim
-
ModSim32 is a very simple but powerful application for simulating data from modbus slave devices. ModSim is an MDI application which allows you to define multiple blocks of data points which may then be accessed from a connected modbus master.
-
Product
Multi-Function Power Transducer
TD2418B
-
The TD2418B is a micro-process based transducer with a 16 bits CPU (Center process unit) and equipped with full-digitized measuring, calibrating and output functions.TD2418B not only can take the place of several static con-verters and measuring instruments (V, A, W, PF, VAR, WH, VARH, Hz) by single unit, but also have some special function such as Maximum measuring, Minimum measuring and comparator output. In communication, we use the most convenient and the easiest RS232 or RS485 as our standard output port, besides, we adopt Modbus Protocol, one of the most popular protocol in the world, as our standard protocol.
-
Product
8Thermocouple Modbus RS-485 Remote I/O
ADAM-4019+
-
8ch thermocouple(can be set to voltage or current)Protocols:Modbus RTU,ASCIIWatchdog timer to recover the system3000VDC isolation protectionWiring burned-out detection function
-
Product
2Counter/2DO Modbus RS-485 Remote I/O
ADAM-4080
-
2ch counter/2ch digital outputProtocols:Modbus RTU,ASCIIWatchdog timer to recover the system2500VRMS isolation protectionCounter frequency up to 50kHZ
-
Product
Ethernet to Modbus RTU Interface
Model 9099
-
* Use Modbus TCP/IP, VXI-11, or Raw Sockets (Telnet) or to control Modbus RTU slave devices.* No special driver required which eliminates driver problems.* Controllable with Windows PC programs like C, Visual Basic, LabVIEW, VEE, etc that make VISA or SICL calls.* Controllable from MAC/UNIX/LINUX and similar computers with RPC calls.* Interfaces with PLCs or any Modbus TCP/IP Controller.* Fully VXI-11 compliant.* Works with Agilent, NI and Kikisui VISA libraries.* Internal webserver with sample Modbus device control pages for Watlow F4, F4T and EZ-Zone Controllers.* Network connectivity eliminates GPIB Bus Extension problems.* Allows multiple users to access the Modbus network or devices.* 9099 is a 2x to 5x faster than the 8099 and includes a new Modbus device control page.
-
Product
EtherCAT Gateways
-
EtherCAT Fieldbus gateways provide seamless communication between Modbus RTU/TCP and EtherCAT communication protocols.
-
Product
Web Data Logger
HD50… Series
-
Datalogger with integrated Web Server. Wi-Fi and Ethernet connection with proprietary TCP/IP or Modbus TCP/IP protocol.
-
Product
Total Tank Level System
-
The Total Tank Level System is an intrinsically safe and explosion proof level sensor with several communication options. Outputs include Modbus RTU digital, dual 4-20mA and HART. The Modbus version is offered in a single housing and the 4-20mA and HART output product features a dual compartment housing and display.