Reactors
-
product
Automated Membrane Permeation Analyzer
MBR
The MBR is a dedicated membrane testing reactor for studying the selective gas permeation properties of membrane materials for separation and purification applications. It is a fully automated system, and is supplied with an integrated close-coupled mass spectrometer.
-
product
Harmonic Filters
ENTES Harmonic Filter Reactors are used in serial connection with capacitor banks in power factor correction units. By using these types of detuned reactors it is possible to increase the capacitor impedance against harmonic currents and to keep the resonance frequency under the frequencies in which main harmonic currents occur by shifting the resonance frequency.
-
product
NanoSpectralyzer
NS1
ANF offers the NS1 NanoSpectralyzer®, a unique automated fluorimetric analyzer based on the most advanced research in nanotube spectroscopy. This patent-pending instrument combines a specialized optical system with custom software to enable efficient, turn-key analyses of bulk SWNT samples. The NS1 NanoSpectralyzer is valuable for tuning the process conditions in SWNT growth reactors, for quality control, for guiding nanotube sorting and separation methods, and for a wide range of research applications that require detailed compositional data on a rapid time scale.
-
product
Reactors
Chengdu Mengsheng Electronics Co., Ltd.
Reactors (also called inductors) are key power equipment used to regulate current, voltage and harmonics, and are widely used in power transmission, distribution systems and power electronic equipment. Our reactor products include single-phase reactors, three-phase reactors, air-core reactors, iron-core reactors and, which can meet the needs of different application scenarios. Designed and manufactured with high-quality metal materials and insulating materials to ensure high efficiency and safety and stability, and provide a variety of cooling methods such as natural cooling, forced air cooling and oil immersion cooling, suitable for various environmental conditions. With excellent performance and reliable quality, our reactor products can effectively improve the stability and reliability of the power system and meet the stringent requirements of modern power systems.Browse our electrical reactor products, if you need customization, please contact our team.
-
product
Compensating Reactor
The compensating reactors are accessories for the CTS-12KSA/ACTS-12K Capacitance & Tan Delta Test Set. The use of one or more compensating reactors increases the capacitance that the internal power supply can excite to conduct measurements. As the measuring range of the CTS-12KSA / ACTS 12K exceeds the kVA rating of the internal power supply, one way of using the test set over its entire measuring range is to form a resonant circuit with the test sample. The use of one or more compensating reactors forms partial resonating circuit with the test specimen, thereby reducing the power supply requirement.
-
product
Air Core Neutral Grounding Reactors
Neutral Earthing (Grounding) Reactors, which resist current flow through inductive elements, are single phase reactors generally connected between ground and neutral of transformers or generators in order to control single line-to-ground faults at a desired level.
-
product
Protein Sequencer
PPSQ-51A/53A
The PPSQ is an instrument for determining the amino acid sequences of proteins and peptides, which combines an Edman reaction section with a high performance liquid chromatograph (HPLC). There are 2 types: the PPSQ-51A, which is equipped with one reactor, and the PPSQ-53A, which is equipped with three reactors. On the PPSQ-53A, the continuous analysis of the amino acid sequences of multiple samples can be performed one after another. In the Edman reaction section, amino acids are cleaved in order from the N-terminal of a protein by repeatedly performing Edman degradation, and are derivatized. As a result, stable PTH-amino acids are produced. The PTH-amino acids are injected online into the HPLC, and analysis is performed. The HPLC data is saved on the PC, and data processing software is used to process the chromatograms. Then, amino acid sequence estimation software is used to identify the amino acids and estimate the sequences.
-
product
Point Contact Diodes
SemiGen’s 1N Series of Point Contact Mixer Diodes are designed for applications through KA band. Each device in this series is specially designed for low noise gure, impedance and VSWR. Our devices are drop in replacements for all military and commercial requirements. These diodes employ epitaxial silicon grown in a speci c reactor for optimized performance. They are suitable for use in stripline applications.
-
product
H2/O2 Analyser For Nuclear Power Plants
Our high performance analytical systems have been used in the nuclear industry since 1980. They enable operators to monitor hydrogen and oxygen levels at critical locations within both boiling water reactors (BWR) and pressurised water reactors (PWR).
-
product
Nuclear Industry Instruments
The Failed Fuel needs accuracy to Identify Leaking Nuclear Fuel in both Pressurized Water Reactors and Boiling Water Reactors in Nuclear Power Plant.
-
product
Food And Environmental Safety Radiation Sampling Lab
Spectrum Analyzer with Low Radiation Lead-Lined Test Chamber. Fully Integrated Touch Screen Control. High Throughput. High Sensitivity. Measures Key Reactor Radionuclides Cs137, Cs134 and I131.
-
product
kSA Scanning Pyro
For use on Veeco K465i and EPIK700 MOCVD reactors, the kSA Scanning Pyro performs automated temperature mapping in order to measure temperature variations across wafer carriers and wafers. Use it to tune heater zones and optimize process and hardware to achieve higher yields, wafer uniformity and device performance.
-
product
Reduced Voltage Motor Starting Panels by Reactors
A method to limit motor starting current is a series reactor. Iron core or air core reactors can be used for starting purposes. If an air core is used for the series reactor then a very efficient and reliable soft starter can be designed which is more suitable for high MW ratings of synchronous/induction motors at MV levels. The reactors are designed with taps.
-
product
Well Plate Illuminator
WPI
Luzchem’s WPI - Well Plate Illuminators are benchtop reactors designed for use in the research or education lab. The WPI is designed for use with a 24 Well Plates or with vials. Currently offered in 400 nm, Cool White 4000K, Blue, Green, broad Green (Lime GR2), Amber, Red and 720 nm (Deep Red)
-
product
AC Resonant Test System
Yangzhou Power Electric Co., Ltd
Testing of certain apparatus requires much high voltage or current that a straight AC test system is not sufficient. Thus resonant test reactor with a variable core is needed. The main advantage of such test systems is lower input power and larger output power. The resonant test system is designed to compensate capacitance in the testing circuit precisely by tuning inductance of the test system. AC resonant test system is used for factory testing of middle, high and ultra-high voltage cables, capacitors, generators, motors, power transformers and gas-insulated switchgears.
-
product
Automated Breakthrough Analyzer
ABR
The ABR is a dedicated breakthrough analyzer with fully programmable operation including control of total pressure, flow rate, composition and temperature. Samples are loaded into interchangeable reactor beds and dried in-situ with purge gas or vacuum at elevated temperature. Reactive gas mixtures are then flowed through the bed, and the downstream composition determined in real-time with an integrated mass spectrometer.
-
product
Reactor Loss Measurement Systems
Measurements International Ltd.
The AccuLoss® SR2020 System by Measurements International emerges as a premium, dependable solution tailored for measuring losses in high-voltage shunt reactors. Specifically engineered to function seamlessly at remarkably low power factors, this system excels in applications demanding extensive scalability. Notably, the AccuLoss® SR2020 System offers two key advantages: unparalleled accuracy and remarkable speed.
-
product
Shock Reactance
ICR260 330
Lifasa - International Capacitors, SA
Shock reactors are necessary to limit the transient currents that occur in the connection of the capacitors.
-
product
Load Cells & Mounting Kits
Load cells are commonly used to measure weight in an industrial environment. They can be installed on hoppers, reactors, etc., to control their weight capacity, which is often of critical importance for an industrial process.
-
product
Iron Core Current Limiting Reactors
Current Limiting Reactor (CLR) is one of the most effective short circuit current limiting devices. It reduces stresses on busses, insulators, circuit breakers and other high voltage devices. Use of CLR is the most practical and economical approach at current limiting.
-
product
Neutron Flux Monitoring Systems
To monitor reactor core neutron flux and provide indication during all modes of reactor operation, and to provide trip signals to the Reactor Protection System (RPS) and the Reactor Manual Control System (RMCS).
-
product
Condenser for Harmonic Protection
FMLF 7%
Lifasa - International Capacitors, SA
These LIFASA capacitors are designed to be connected in series with INR or INA reactors, and thus form a harmonic filter tuned to a frequency of 189 Hz (lower than the first harmonic present in the network). The nominal powers of the filters indicated in the table are obtained by being connected to the reactors.
-
product
kSA ICE
The k-Space Integrated Control for Epitaxy system (ICE) is a modular in situ metrology tool designed for today’s MOCVD and MBE reactors. It combines kSA MOS, kSA BandiT and kSA RateRat Pro patented technologies along with an Emissivity Corrected Pyrometry (ECPR) module. The kSA ICE modular design allows the user to specify which modules will be used in their kSA ICE configuration.
-
product
Highly Inductive Resistance Meter
MR 8050
With the MR 8050 resistances highly inductive Resistance Meters windings of transformers, motors and reactors can be measured. (range 100 µΩ with 0.01µΩ resolution up to 6 kΩ). The performance of the test objects can be up to 800 MVA or even more. The magnetic loading of a transformer is performed quickly using a high loading voltage (60V). This is important for time critical measurements (cooling curves). The unloading of the transformers core is very fast, very safe, as the energy is total destroyed in the MR 8050.
-
product
Gas Analysis
QIC BioStream
A gas analysis system for continuous analysis of gases and vapours from multiple fermentation reactors with multi off gas and multi reactor dissolved gas species analysis capability. A high-performance Proteus multi-stream valve supplied with 20, 40 or 80 inlet streams is included with programmable sequence control software for analysis of multiple reactors. Streams can be allocated for either dissolved species analysis or off gas analysis.
-
product
Air Core Current Limiting Reactors
Current Limiting Reactor (CLR) is one of the most effective short circuit current limiting devices. It reduces stresses on busses, insulators, circuit breakers and other high voltage devices. Use of CLR is the most practical and economical approach at current limiting.
-
product
Air Core Line & Load Reactors
Line and load reactors are generally serial-connected to the input and/or output terminals of three phase equipment such as motor speed controllers, inverters and UPS systems. These equipment make use of semiconductor switches such as IGBTs, thyristors, and diodes and therefore create harmonic distortion and high switching over-voltages (dv/dt). Use of such equipment has been becoming more widespread as the technology advances. However, the negative effects of these equipment should not be overlooked.
-
product
Saturable Reactor Inductors
Osborne Saturable Reactors are designed to provide a variable output voltage through the use of variable impedance connected in series with a constant impedance load. Each saturable reactor’s impedance is determined by the application of DC power to a control winding. As the level of power supplied to the control winding is increased, the saturable reactor becomes more saturated. This reduces the impedance of the AC gate winding, and increase the amount of the supply voltage that is transferred to the load. Conversely, as the power is reduced to the control winding, the reactor becomes less saturated, the gate winding has more impedance and less of the input voltage is provided to the output impedance. This approach provides excellent quality, reliability, and control when designed to match the requirements of a specific application.
-
product
HV AC Voltage Test Systems
Fivestar HV Testing Equipment Co., Ltd.
FSHV offers three different types of AC voltage test systems, the conventional type is AC test transformer design, mainly for testing objects of medium & low capacitance products, particularly for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (like inductive voltage transformers). Another is AC resonant test systems, according to series resonance circuit XL=XC (2πfL=1/2πfC), by setting F frequency of power supply or L inductance of reactor, generate a pure sinusoidal waveform of the test voltage, and the required input power is only 1/Q. Variable frequency type operates in a frequency range from 20Hz to 300Hz, ideal for field commissioning test of power cables and GIS/GIL. Variable inductance type outputs continuous AC voltage of power frequency (50/60Hz), mainly for factory testing of high and ultra-high voltage cables, power transformers, GIS, etc.
-
product
Coriolis Mass Flowmeters
CMF
Applicable Fluids: Gases Slurries Liquids. Typical Applications: Custody transfer Reactor feed ratio Density measurement Batch control.





























