Filter Results By:
Products
Applications
Manufacturers
Spectral Response
sensitivity of sensor to a specific wavelength over a spectral band.
See Also: IPCE
-
product
Digital Lux Meter
PM-3
Is a compact, lightweight & easy to use Illuminance meter. The sensor is a highly stable silicon photo diode having a wide measuring range. Its spectral response is closely matched with the CIE relative photopic luminosity curve by multi-element glass filters. The sensor is also cosine corrected for true response at variable incidence angles.
-
product
Solar Energy, PV Monitoring
Apogee silicon-cell pyranometers feature a monocrystalline silicon-cell detector that has the same spectral response as a PV module. The sensors quantify shortwave radiation being harnessed as electricity.
-
product
UV A Radiometer
UVS-A-T
The UVS-A-T has a broad spectral response optimised for precise measurements of atmospheric UV-A irradiance.
-
product
Hybrid Picosecond Photon Detectors
HPPD Series
technology.The HPPD is our latest development in TCSPC detector technology that combines the benefits of conventional PMT design (wide spectral response and large active area)with the advantages of solid state APD technology (good detection efficiency, negligible after-pulsing and exceptional temporal resolution). Hybrid detectors are becoming thefirst choice for FLIM and short lifetime determination.
-
product
Spectral Response SystemsQuantum Efficiency SystemsIPCE Measurement Systems
QE system provides electronics and software designed for fully automated measurement of external quantum efficiency of solar cells. All systems include probes and a fixed plate sample stage for samples up to 150 mm x 150 mm. The main system components include: custom designed software, measurement electronics, and computer system (Windows 8 operating system). The measurement involves focusing monochromatic light to a spot on the device under test, then accurately measuring the photon flux and current from the test cell. The system utilizes a dual beam configuration with lock-in detection, providing an absolute accuracy of ±3%. The QE system uses a grating monochrometer with silicon/InGaAs/Ge detectors. The system includes automatic order sorting filters and two light sources for monochromatic illumination (a Xenon- arc lamp and a halogen lamp). A single lock-in amplifier is used to measure both the reference detector and test device. The main system comes with all the hardware needed to measure quantum efficiency, a fixed plate sample stage and probes.
-
product
Luminance Probe
LP471LUM2
Photometric probe for measuring the LUMINANCE, spectral response according to the photopic curve, angular field 2°.
-
product
UV Photodiodes
Active area from 0.06 mm² to 36 mm² and quadrant photodiodes for position detections. Spectral response for broadband UV or filtered for UVA, UVB, UVC or UV-Index. Various entrance optics and housings options available (TO or SMD). Our own SiC photodiode chip production since 2009 also available with VUV sensitivity. PTB (German equivalent of NIST or NPL) measured high radiation hardness. 350°C high temperature stable photodiodes available. Photodiode application guide.
-
product
Pyranometer Negligible thermal gradient zero-offset
CMP 22
CMP 22 has all the features of CMP 21 but uses very high quality quartz domes for a wider spectral range, improved directional response, and reduced thermal offsets. Because of the high optical quality of these domes the directional error is reduced below 5 W/m. Kipp & Zonen is confident that CMP 22 is the best Pyranometer currently available.
-
product
Ultra-Micro Spectrometers
UltraMicro
spectro-module is constructed by a new invented technology and can provide high optical resolution and fast spectral response. The optical engine is very simple and optimized for the spectrometer. The optical bench is very rigid and stable for measurement system. The compact size is very flexible for system integration.
-
product
SiTek Standard PSD
1L20_CP3
The SiTek Standard PSD (Position Sensing Detector) has high resolution, fast response and outstanding linearity. It is used in a wide variety of applications, most of them utilizing light sources in the visible or near-infrared part of the spectrum. The spectral range covers the region 400 - 1100 nm. Thanks to SiTek's proprietary AR-coating, optimized around 860 nm, a reflection loss of only 2% is achieved around the responsivity peak. Most of the detectors have a cover window to avoid handling damages.
-
product
Energy Probes
RjP-400 Series
The RkP-400 Series probes consist of a compact detector assembly, or head, and a preamplifier housed in a separate enclosure. The external dimensions of all the 400 Series Probes are the same, with identical detector planes, allowing for easy interchange of probes in an experiment. The heads have both ¼-20 and M6 tapped holes, a built-in 1" (25mm) filter holder, and a side-mounted BNC connector. Probe specific data, including spectral response curves and calibration dates, is stored in the preamplifier for access by the instruments.
-
product
UV TOCONs
SiC based UV sensor with integrated amplifier and 0 – 5 V voltage output. Measures intensities from 1.8pW/cm² up to 18W/cm². Spectral response for broadband UV or filtered for UVA, UVB, UVC or UV-Index. Also available for blue light (GaP chip) or visible light (Si chip) measurement. Available in TO5 housings or as miniature sensor probes (stainless steel or plastic). Special TOCONs for hydrogen flame sensing (TOCON_F) and for fire detection (TOCON_N) available. Also available for operating temperatures up to 120°C (standard is 85°C). Please learn more about the sglux TOCONs here: TOCON selection guide and here: TOCON User Guide.
-
product
Custom Test Systems
ATE Systems has developed a wide variety of custom test systems that integrate commercial test instruments and custom hardware, tied together with a test executive. Examples of the types of tests that have been incorporated include: S-parameters (gain, return loss, VSWR, etc), Noise figure, Power, Spectral response, Linearity, Voltage, Current, Switching speed and so on
-
product
SiTek UV PSD
The UV PSD is a detector optimized for use in the UV wavelength region 200-400 nm, although its spectral response reaches up to 1100 nm. The sensitivity in the UV region (200-400 nm) is extremely high. The UV-PSD has the same outstanding specifications as the standard SiTek PSD.
-
product
2 Channel Variable Optical Attenuator
S-105
VOA slot module of FOTS system is a module that installs a built-in dual channel MEMS type VOA inside and can do two separate attenuation functions with two each VOA channel being driven individually. This module controls the optical power precisely to maintain the desired output level set by the user by automatically correcting for power drift or fluctuation.This slot module provides high-performance power control features such as high attenuation range, accurate tolerance, stable spectral flatness and low insertion loss in the wavelength range of 1260 ~ 1600 nm. It also offers a particularity that the high-speed drive of attenuation is possible through the combination of high-speed FPGA processor and high speed response time (within 1 ms) VOA. With the provided driving program and GUI, users can set up various attenuation program of each VOA channel such as sequential attenuation step, periodic attenuation and operation time
-
product
Computerized Knife-Edge Tomography (CKET)
Many new generation lasers, having a spectrum which is out of the sensitivity response of typical camera detectors require different technologies to be ex-amined. Tomographic knife-edge technology offers a feasible solution. Multiple knife-edges scanning from different directions provide beam profiles depen-dent on scanning angle. By reconstruction techniques used in tomography, an image-like profile can be reconstructed and analyzed. Various detectors are used to provide a wide spectral range measurement capability
-
product
Ambient Light Sensors
Renesas' ambient light sensors can adjust a display’s backlight, which improves user experience and power savings by optimizing the display’s viewability. Their ultra-low light sensitivity, low power consumption, ideal spectral response, and easy to use simple output algorithm make them best-in-class. We offer a full suite of light-to-analog and light-to-digital solutions to suit your applications requirements and budget.
-
product
Handheld Raman Analyzer
TacticID®-1064
The TacticID®-1064 is a field-ready handheld spectral analysis instrument designed for non-contact forensic analysis by safety personnel and first responders, including law enforcement personnel, bomb squads, customs and border patrol, hazmat technicians, and more. The TacticID®-1064 utilizes proven Raman spectroscopy, allowing users to get real-time actionable identification of unknown chemicals, explosives, narcotics, pharmaceutical drugs and many other substances while reducing operational uncertainty and response time. The TacticID®-1064 includes a comprehensive library of over 10,000 substances. In addition, users have flexibility to create their own libraries. By utilizing the 1064nm wavelength, the TacticID®-1064 avoids fluorescence, allowing users to get results in less than 1 minute even when working with tough street samples.
-
product
Extreme Low Power Detector Laser Power Meters
11XLP12
11XLP12 extreme low power detector is best suitable for low power im both the µW and mW regimes with very low thermal drift. Featuring broadband flat spectral response, minimal thermal drift and a noise equivalent power as low as 1 µW the 11XLP12 is ideally suited for measuring any pulsed or CW low power laser.
-
product
Frequency Response Function
FRF
FFT Spectral Analysis. Frequency Response Function (FRF) is a commonly used measurement type of the Dynamic Signal Analyzer. FRF is defined as the ratio of response i.e. acceleration, velocity, or displacement with respect to the excitation force which is the reference.
-
product
Spectral Response (Spectral Sensitivity) Measurement
It is used to measure the spectral response (spectral sensitivity) of photoelectric conversion devices (photodetectors / sensors) such as silicon photodiodes and CCD · CMOS image sensors . Measurement in the broadband wavelength region can be performed with low stray light.
-
product
Illuminance Probe
LP471PHOT
Photometric probe for measuring the ILLUMINANCE, spectral response according to the photopic curve, class B according to CIE N° 69, cosine correction diffuser.
-
product
Radiometer Spectral sensitivities precisely adapted to the measurement task
UVS-B-T
Compared to the spectral response of the UVS-E, the UVS-B-T has a sharper cut-off at the transition from UV-B to UV-A. This feature reduces the UV-A contribution to the radiometer output and permits the highest possible correlation to atmospheric UV-B irradiance.
-
product
Power Probes
RkP-400 Series
The RkP-400 Series probes consist of a compact head containing the detector and a preamplifier housed in a separate enclosure. The external dimensions of all the 400 Series Probes are the same, with identical detector planes, allowing for easy interchange of probes in an experiment. The heads have both ¼-20 and M6 tapped holes, a built-in 1” (25mm) filter holder, and a side-mounted BNC connector. Probe specific data, including spectral response curves and calibration dates, is stored in the preamplifier for access by the instruments.
-
product
Complete Testing Solutions
System includes a lamp and monochromator for a tunable light source, which is coupled to a high sensitivity source meter with measurement software. This user-friendly system is the most powerful Spectral Response system currently on the market, but its true power is the ease of upgrading from the base PTS-1 to the more powerful PTS-2-QE (Quantum Efficiency) or PTS-3-CPM (Constant Photocurrent Method). Designed for researchers who have limited budgets but want to start work immediately, this allows the ability to do baseline studies until additional funding for the full QE or CPM system becomes available.
-
product
USB Smart Detector
OL 731
The OL 731 USB Smart Detector is a low-cost, hand-held radiometer/photometer that can be tailored to the spectral response of the user's specific application requirements with the use of a range of sensors and filters. Several units can be multiplexed on to one USB, and it can be programmed to read in any user-specified radiometric or photometric unit. The OL 731 is suitable for a variety of critical applications.
-
product
Dynamic Gas Analyser
ExQ
The Hiden ExQ quantitative gas analyser is a new multi-featured and compact mass spectrometer system providing continuous on-line analysis of dynamic gas streams at pressures from sub-atmospheric up to 30 bar, the fully integrated system now being configurable both for benchtop and for rack-mounting operation. Connection to the process is via a flexible heated inert capillary line with a sample consumption rate less than 10 mL/minute and a response time of less than 300 milliseconds at pressures near atmosphere. The comprehensive range of process interface options enables adaptation of the system to accommodate analysis of up to 16 individual process streams, and adaptors are available for direct connection of the system to most standard TGA/TA instruments. External process data, sample temperature or mass for example, can be imported for combined integration and presentation with the mass spectral data.
-
product
Image Sensor/Fingerprint-on-Display Testing
Enli Tech provides the most advanced optical and non-destructive inspection technology, which can de-convolute the digital images back to the analog properties, such as quantum efficiency, spectral response, system gain K, Dynamic Range (DR), PRNU, DRNU, Linearity Error LE, and Chief-Ray-Angle (CRA). The testing solution can be applied to CCD and CMOS image sensors in aerospace, defense, and scientific camera field. Image sensor packages that can be tested by Enli Tech’s systems include bare wafers, dies, chips, or camera modules. Our image sensor testers can help users reduce the sensor-modules or camera-modules development time and RD budget.
-
product
Custom Detectors
Besides the described types Inphora can supply detector-filter combinations with parameters matching the customer's special requirement, with different sized housing, without housing. If the application determines the detector's spectral responsivity, we can achieve that with a filter designed exactly to the specifications. CCD cameras with unusual spectral sensitivity functions can be matched with filters to obtain CIE tristimulus response or photopic response. Similarly, photmultiplyers can be matched also with INPHORA filters. When determining parameters for a custom detector-filter combination several details have to be considered:
-
product
Radiometer Spectral sensitivities precisely adapted to the human skin
UVS-E-T
The UVS-E-T has a spectral response that is adapted to the erythemal (sunburn) action spectrum of the human skin (CIE 1987 weighting). Hence, this radiometer collects information of medical and public concern: UV Index, UV Erythemal dose and dose rate.