measure the rate of voltage to current in a circuit at a specified frequency.
See Also: LCR Meters
-
product
50Hz-100kHz LCR Meter
11022/11025
Chroma Systems Solutions, Inc.
0.1% basic accuracyTransformer test parameters (11025), Turns Ratio, DCR, Mutual Inductance0Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, 100kHz test frequencies21ms measurement time (≥100Hz)Agilent 4263B LCR Meter commands compatible4 different output resistance modes selectable for non-linear inductor and capacitor measuringHigh resolution in low impedance(0.01mΩ) and high accuracy 0.3% till 100mΩ rangeAdjustable DC bias current up to 200mA (constant 25Ω) (11025)1320 Bias Current Source directly control capability0.01mΩ ~ 99.99MΩ wide measurement range (4 1/2 digits)Dual frequency function (11022 option) for automatic productionBIAS comparator functionComparator function and 8/99 bin-sorting functionPass/fail judge result for automatic productionHandler interface trigger edge (rising/falling) programmableTest signal level monitor functionStandard RS-232, GPIB, and Handler I/FOpen/short zeroing, load correctionLabView® Driver
-
product
Electrical Circuit / Wire Harness Analyzer
ECAD System 2005
The ECAD System 2005 is a suite of test instruments for both lumped and distributed data for analysis of electrical circuits and/or wiring harnesses. ECAD is completely self contained, and has a built-in multimeter, impedance meter, TDR, and megohmeter.
-
product
Impedance meters
Electronic components meters for circuit verification in laboratories, technical schools and technical support centres.
-
product
Bench Meters
LCR Meters
The measuring objects of LCR Meters are the parameters of impedance components, including resistance R, inductance L, quality factor Q, capacitance C and loss factor D. The selection of digital bridge should consider the highest frequency, test accuracy, test speed and DCR test function of the tested device.
-
product
Analog Tank Test Kit
4108
The voltmeter included in the kit, the “Model IA” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers a 0 - 2VDC range with a 10MΩ input impedance and the analog display presents a color divided scale for convenient indication as to whether or not a carbon-steel structure is receiving a suitable level of cathodic protection, with respect to the accepted 0.85V (850mV) threshold value.
-
product
High Current Short Circuit Loop Impedance Meter
AMZC-310S
Measurement of very small short-circuit loop impedances (with resolution of 0,1mΩ) using the current of 150A under 230V, maximum 280A under 440V, or measurement using the current of 23A under 230V, maximum 42A under 440V
-
product
iSimulator Impedance Simulator
Z1000
Measurements International Ltd.
With the release of the commercial Z1000 iSimulator, the process for calibration of LCR meters has been taken to a new level. The Z1000 covers the full calibration of LCR meters over simulated impedances from 100 Hz to 20 kHz while eliminating the need for external standards and providing a much simpler, easier-to-use method of LCR meter calibration.
-
product
Earth Contact Resistance Tester
SCR ELEKTRONIKS have developed an equipment namely Earth Contact Resistance Tester to test the appliance. To ensure the safety of operator it is essential that the Earth path (connection) should offer minimum impedance to by pass short circuit Current to Earth. This is ensured by measuring Resistance of the Earth path by passing heavy Current say 25 A. The Earth Contact Resistance Tester essentially comprises of a Variable Current source with digital Ammeter to measure the Current supplied. The Voltage drop across the Earth path is measured with a digital Voltmeter. Optionally for a particular Current (25 A) the meter can be calibrated in terms of Resistance. A timer is provided to switch off the Current after the Set Time.
-
product
300KHz Precision LCR Meter
Model 4300R
Aplab Precision LCR Meter Model 4300R is a new generation of impedance test equipment with high accuracy, wide measurement range and six digits resolution. Being featured with test frequency up to 300kHz, test voltage of 5mV ~ 2V, built-in -5V ~ 5V DC bias and -10V~10V DC voltage source output, it can meet all requirements for measuring components and materials and provide guarantees for production line quality assurance, incoming inspection and laboratory precision measurements. The Handler, RS232C and GPIB interfaces as well as improved command system provided by the instrument make it easier to build the test system.
-
product
AC/ DC mA Current Clamp-on Transducer
CA-60
This miniature clamp meter features two Hall effect sensors. For use with any multimeter with 200mV or/and 2V ranges for direct readout input impedance of least 1M ohm. High conversion factor for low DC and AC mA measurement. With the small jaw size it can fit into tight space in circuit panel or wire bundle to take the reading.
-
product
Audio Generator & Impedance Meter
MR-PRO/MR2
The Minirator MR-PRO provides a full set of analog audio signals including sine wave, pink noise, white noise, delay test signal, polarity test signal, stepped sweep and continuous sine sweep. Further, a set of wav-files, useful for system optimization, is stored in the internal flash memory. Add your own personal favorites to this set.
-
product
FC Impedance Meters
designed for testing of the fuel cell with the small current (5 A or less), and not only the current-voltage characteristic test, the KFM2005 can easily measure for the impedance of a fuel cell using the AC impedance method, and the Cole-Cole plot. Using the measurement data of the Cole-cole plot, it is possible to calculate the circuit constant of the approximate equivalent circuit of the fuel cell. The built-in DC load (60W) is capable to operate from 0 V, and it can perform the test for the fuel cell up to 20V and 5A.
-
product
LCR Meter
MCR8000 Series
MCR8000 Series is a LCR meter also called impedance analyzer with high precision and high quality. With new 32-bit core, as good as first class equipment. 7 inche true color TFT display. 20Hx-5MHz testing frequency, frequency point continuously adjustable.
-
product
LCR Meters And Impedance Measurement Products
Complete impedance measurement solutions to meet your needs from LCR to impedance meters, plus test accessories for various R&D and manufacturing applications.
-
product
Impedance Standards and Calibrators
Impedance Calibrator is to replace countless single value RCL standards with one calibrator that can switch between the standards like a CD changer in your car. The calibrator contains stable and temperature independent resistance standards, partial capacitance standards and partial inductance standards, simulated by RC T-type passive network. Calibration values of both complex parameters of partial standards are displayed on large LCD screen in preselected pairs of parameters as well as voltage, current and frequency readouts from built-in test signal meter. OPEN and SHORT reference positions are available as well.
-
product
Battery Impedance Meter
Operation is fast and simple. Just press the spring-loaded probes onto the two poles of the battery. After 1.5 seconds, the unit beeps (indicating good contact) and displays the battery voltage and either the number of siemens or milliohms, depending on the knob setting. The display continues to show these numbers after the probes are removed; it resets only when the probes are pressed onto the next battery. The impedance and voltage of any battery between 1.2 and 60 volts can be read. Because of the wide range of voltages, even single low-voltage cells, such as NiMH, can be measured. The manufacturers of some batteries specify impedance in milliohms while other specify in siemens (one divided by the resistance in ohms). This meter will display both types of impedance for any given battery. Accuracy is +/- 2% of the value.
-
product
Dielectric Test Fixture
16451B
The 16451B is used to evaluate the dielectric constant of solid dielectric materials accurately, and complies with ASTM D150. The 16451B employs the parallel plate method, which sandwiches the material between two electrodes to form a capacitor. An LCR meter or an impedance analyzer is then used to measure the capacitance created from the fixture.
-
product
Short Circuit Loop Impedance Meter
AMZC-305
Loop impedance measurement with resolution 0,01Ω ; Loop impedance measurement without tripping the circuit breaker > 30mA with resolution 0,01Ω (100...440V) ; Measurements possible in installations 110/190V, 115/200V, 127/220V, 220/380V, 230/400V, 240/415V, 290/500V and 400/690V (range 100...750V)
-
product
Liquid Test Fixture
16452A
The 16452A provides accurate dielectric constant and impedance measurements of liquid materials. The 16452A employs the parallel plate method, which sandwiches the liquid material between two electrodes to form a capacitor. An LCR meter or an impedance analyzer is then used to measure the capacitance created from the fixure.
-
product
Impedance Analyzer
MFIA
The Zurich Instruments MFIA is a digital impedance analyzer and precision LCR meter that sets the new standard for impedance measurements in the frequency range from DC to 5 MHz. The MFIA provides 0.05% basic accuracy and a measurement range spanning from 1 m to 10 G. The instrument has a high measurement repeatability and a small temperature drift. With the LabOne user interface the MFIA offers a number of long-awaited innovations for the impedance and LCR measurement available without the need of any software installation.
-
product
Short Circuit Loop Impedance Meter
AMZC-304
Short circuit loop impedance measurement in networks with nominal voltage: 220/380V, 230/400V, 240/415V, with frequency 45…65Hz ; Short circuit loop impedance measurement with 15mA current, without triggering RCD. ; Detection of the replacement L and N in the socket and automatic swap in the meter
-
product
Precision LCR Meter, 20 Hz to 2 MHz
E4980A
The E4980A precision LCR meter provides the best combination of accuracy, speed, and versatility for a wide range of component measurements. Offering fast measurement speed and outstanding performance at both low and high impedance ranges, the E4980A is the ultimate tool for general R&D and manufacturing test of components and materials. LAN, USB and GPIB PC connectivity enhances your design and test productivity.
-
product
Digital kV Meter
VM-10, VM-20 , VM-30
UDEYRAJ ELECTRICALS PRIVATE LIMITED
High Voltage Meters measure AC and DC voltages of up to 30kV with high accuracy. The meter input impedance is as high as 1000 M ohm, making the meter suitable for measurement of voltages of high source impedance circuits. Meters are compact and light weight and can be conveniently used as a calibration meter.
-
product
Open Termination, 4-Terminal Pair
42090A
The 42090A is an open termination and is primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using this standard.
-
product
Audio Frequency Oscillator
PD-5
2.5- 100 volt output6 position output voltage selectorCompatible with all "Mark" receivers (Mark II, III, IV, V)Pulse "Identifying" signalBattery charging circuit built-inLED impedance meter
-
product
Attenuators And Pulse Limiters
A bidirectional attenuator, i.e. the attenuation and power capability specification is valid for both directions. There is a large variety of applications for this attenuator: The measuring range of a spectrum analyzer can be increased. Any kind of meter can be protected against overload; it can be used to control the linearity of a meter reading. It can minimize measurement uncertainty caused by mismatched impedances. During an EMI receiver calibration an attenuator directly at the pulse generator output is inevitable.
-
product
Precision Impedance Meter
1689
The GenRad 1689 Precision Impedance Meter gives you the best performance for your most demanding applications whether they be production test, incoming inspection, component design and evaluation, process monitoring or dielectric measurement. It is a versatile, full function microprocessor-based passive component tester that's available in a rack mountable, (1689M) model.
-
product
Electric Fence Chargers
Mark 8
Parker McCrory Manufacturing Co.
The all new Mark 8, low impedance fencer gives you the stock holding power that you have always wanted. Shocks right through wet weeds or brush and over extremely dry ground. Features Parmak`s exclusive built-in DIGITAL performance meter that tells you the exact condition of the fence. Takes the guesswork out of electric fencing. 100% solid state, with all new low impedance, uni-junction circuitry. No moving parts. Ideal for use with high tensile single or multi-wire fences. New color coded fence and ground terminals. Red to the fence and Black to ground. The Mark 8 operates for less than 7 cents a month at 7 cents per kwh. Fuse protection, with new built-in lightning arresters. Full 3 year warranty covers damage caused by lightning.
-
product
FC(Fuel Cell) Impedance Measurement System
KFM2150 System
The KFM2150 system is a fuel cell impedance measurement system configured with an FC impedance meter KFM2150 and an electronic load PLZ-4W series. Combination of KFM2150 and PLZ-4WA series (0V input type) supports impedance measurement for single cell of fuel cell.In addition to impedance measurement with AC impedance method, KFM2150 system provides IR measurement with current interrupt method.Application software enables test for each characteristic of fuel cell such as I-V characteristics, Constant Current characteristics, Current Interrupt method and Cole-Cole plot by the AC impedance method. Moreover, each test can be performed in a specified order.
-
product
Short Termination, 4-Terminal Pair
42091A
Use for performance tests of the 4-terminal pair LCR meters and impedance analyzers.