Filter Results By:
Products
Applications
Manufacturers
-
product
Open Loop Current Sensor
C03 30A
The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.
-
product
Calibrator Process
VA70034
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Loop calibrator This Calibrator is use to measure or output 0 to 24 mA DC current loop, and 0 to 20 V DC voltage.
-
product
12 D/A Outputs (±10 VDC or ±25 mA)
DA1
The DA1 module features 12 independent D/A output channels with a full-scale range of ±10 VDC at ± 25 mA (max). The DA1 provides either voltage or current control loop modes that are programmable for the particular application. The DA1 module also offers external trigger/synchronization signal (RS422/485) capability, which provides/accepts a trigger signal to/from other module(s).
-
product
sbRIO-9265, Non-Enclosed, 4-Channel C Series Current Output Module
780921-01
Non-Enclosed, 4-Channel C Series Current Output Module - The sbRIO‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The sbRIO‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity. Non-enclosed modules are designed for OEM applications.
-
product
Loop Meter
MZC-310S
The MZC-310S is a professional portable meter for testing electrical installations with over-current circuit breakers. The instrument measures short-circuit L-PE, L-N and L-L loop and prospective short-circuit loop current. A measurements can be done either with low testing current (up to 42A) with 2-pole method or high testing current (up to 280A) with 4-pole method that enables measurements with very high accuracy and resolution.
-
product
PXI/PXIe Analog Output/Current Loop Simulator Module - 4 Channel
43-765-004
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
4-Port Serial Interface, Modular, With/Without Optical Isolation, 3.3V
CPCI-7500
*This Model has a 37-pin D-Sub male connector*RS232, RS422, RS485, 20 mA Current Loop*Modular structure through SI modules*With or without optical isolation*Mode configuration free for each port*128-byte FIFO-buffer, common interrupt*Transfer rate programmable up to 115,200 Baud*Option: up to 1 MBaud for RS485 and RS422*Automatic direction recognition for RS48*Mode: configurable RS232, RS422, RS485, 20 mA Current Loop (active, passive) with or without isolation (SI modules)*Transmission mode asynchronous, full, half duplex*Transfer rate: progr. up to 115.2 kBaud up to 1 MBaud on request*Protocol: 5, 6, 7 or 8-bit character 1, 1? or 2 stop bits*Parity: even, odd, none, mark or space*Interrupt lines: automatic through BIOS
-
product
Loop-Powered Transmitters and Drivers
4-20mA
Loop-Powered Transmitters convert the output from proximity probes, seismic sensors, into a 4-20mA DC current, which is proportional to the input being measured. The transmitter converts the displacement or vibration signal to DC voltage and/or current for a DCS or PLC system. They control a 4-20mA current loop for a specified vibration range (ex. 0-5 mils peak-to-peak). The transmitters have a two-wire hook-up, powered solely by the loop current and have a power supply range of 15 to 36 volts.
-
product
Digital Indicators
NOSHOK Digital Indicators provide local indication for pressure, level and temperature transmitters. The NOSHOK Attachable Loop Powered Digital Indicator can easily be fitted to NOSHOK pressure transmitters utilizing a 4 mA to 20 mA output signal and the Hirschmann (DIN 43650A) connector. NOSHOK also offers a dual display model that accepts a wide variety of input signals including thermocouples or RTDs, current, voltage, resistance and process signals. Plug-in option cards are available on several models for field upgrading.
-
product
Insolator
The USB isolators effect a potential decoupling of all USB connections and separate the 'normal' PC system from the critical application. They are the professional tools to avoid and fight ground loops and equalizing currents and to protect against overvoltage.
-
product
High Current Short Circuit Loop Impedance Meter
AMZC-310S
Measurement of very small short-circuit loop impedances (with resolution of 0,1mΩ) using the current of 150A under 230V, maximum 280A under 440V, or measurement using the current of 23A under 230V, maximum 42A under 440V
-
product
Multi Function Testers
Kyoritsu Electrical Instruments Works, Ltd.
Live circuit warning LED:Immediate illumination of a warning lamp if the circuit under test is live Auto Discharge:Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing Integral overload protection on internal continuity and insulation test circuitry Autoranging 500V DC test voltage for insulation tests 200mA short circuit current on continuity ranges Loop and RCD Testing Wiring connection check LED''s:Immediate indication if wiring of circuit under test is correct Overheat Protection:Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement Supply Voltage Indication:Can display supply voltage value in loop impedance mode Low Current Loop Impedance Test:Short duration low test current will prevent tripping of many passive RCDs
-
product
Battery Pack Test System
*Easy to see now test progress*Can cycle test*Provide Charge, Discharge, Suspend, FOR, LOOP Mode Select*When Charging, set the stop current to stop charging when fully charged so as to avoid overcharging that will damage the battery. When Discharge, set the stop voltage to stop discharge when discharging to lowest so as to avoid over-discharging that will damage the battery.
-
product
Short Circuit Loop Impedance Meter
AMZC-304
Short circuit loop impedance measurement in networks with nominal voltage: 220/380V, 230/400V, 240/415V, with frequency 45…65Hz ; Short circuit loop impedance measurement with 15mA current, without triggering RCD. ; Detection of the replacement L and N in the socket and automatic swap in the meter
-
product
Temperature/Process Controller
16B
Monitor and control temperature or process applications with precision using the Series 16B controllers. The units offer two separate outputs for dual loop control in direct or reverse acting. Select relay, voltage, or current output combined with a second relay output
-
product
Current Loop Adapter
OP-1C
This adapter supports current loop communications.The kit incorporates a communications circuit with photo-coupler isolation and constant-current power supply of insulated type, thus realizing not only monitoring but also easy communications testing with passive or active current loop devices.
-
product
NI-9265, 4-Channel C Series Current Output Module
783733-01
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
product
Closed Loop Hall Effect Current Sensors/Transducerswith Rectangle Windows
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used formeasurement of DC and AC current, pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
product
Multifunction Electrical Installations Meter
MPI-525
Possible measurementsShort-circuit loop measurement:*impedance measurement with 23 A current (44 A phase-to-phase) - short-circuit resistor R=10,*measurement range: 95...440 V, frequency 45...65 Hz,Short-circuit loop measurement with resolution 0,01, in distribution network without tiggering RCD (In30 mA):*automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,*additional UNI-Schuko plug for automatic measurement, AGT adapter for 3 phase network measurement.Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000 mA. (Type AC, A and B).Measurement of insulation resistance:*with test voltage 250 V, 500 V, 1000 V, 2500 V,*measurement range up to 10G,*automatic discharging after measurement,*automatic measurement of all resistences in 3,4,5-wire cables using optional adapter AUTO-ISO,*acoustic signals in 5 sec intervals for insulation resistance characteristic,*elapsing T1, T2, T3 times (0...600 s) form measurement of absorption coefficients (DAR, PI or Ab1, Ab2)*safety measurement - protection against overvoltage.Measurement of earthing resistance.Bi-directional testing of PE wire continuity using 200 mA current.*Autocalibration of test leads.
-
product
Microwave Moisture Meter
RX-95
The system works based on the absorption of microwave energy by water molecules contained inthe x-rayed material. It is a non-contact, non-destructive method of instant measurement of water content - used for materials such as coal, flour, grain, cement, seeds, sugar, etc. Thanks to high measurement sensitivity (resolution greater than 0.01% of water content by weight), short measurement time (about 5 times/sec.) and repeatability of measurement - the system is suitable for continuous measurement of material moisture, e.g. on conveyor belts and its recording on a PC or using a 4-20 mA current loop.
-
product
Single Port Serial Interface
APCI-7300-3
*PCI interface to the 32-bit data bus. *Asynchronous communication adapter, 1-port serial interface*1 socket for SI modules*Modular structure through SI modules*Configurable as: RS232, RS422, RS485, with or without isolation, or 20 mA Current Loop (active, passive) with isolation*Addressing through software
-
product
Event Detectors
105/106 Series
The 105/106 Series Event Detectors are the most versatile Event Detectors in the product line. These Event Detectors monitor the electrical resistance of up to 128 simple continuity loops, each comprised of single or multiple specimens under test. Each test specimen is continuously monitored while a selectable DC sense current is passed through each channel test-loop; resistance changes exceeding the selected threshold are recorded as an event. Minimum Event Duration, Channel Current, and Threshold Voltage settings can all be independently configured. 105 and 106 Series instruments are electrically identical, with the difference simply that the 105 offers four, 32-channel board slots and the 106 offers only one. Thus the 128-105 is equivalent to four 32-106 Event Detectors.
-
product
Open Loop Hall Effect Current Sensors Transducers With Rectangle Windows
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on open loop principle and designed with a highgalvanic isolation between primary conductor and secondary circuit. It can be used formeasurement of DC current, DC pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
product
Measurement & Simulation
Highland Technology offers a wide array of tools for measurement, simulation, and control. Tachometers, thermocouples, RTDs, precision voltages, current loops, strain gauges, and more can be measured or simulated by Highland's products.
-
product
PC Based High Current Test Set for Circuit Breakers and Temperature Rise Test Equipment
This equipment comprises of high current source for testing of circuit breakers with additional facility for temperature rise testing (thus incorporating testing for moulded case, vacuum & air circuit breakers as per IEC 60947-2). The system integrates a servo controlled source with closed loop current feedback to maintain the current constant. It has the necessary instrumentation for maintaining current at full load & other conditions arising in testing at high current. The bench has a PC based control system with temperature data logger (24 channel with ch-ch isolation amplifiers). The data logger displays as well as stores a set of temperature values with time.
-
product
PXI/PXIe Analog Output/Current Loop Simulator Module - 12 Channel
43-765-002
The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
IntelliPoint RF - Loop Powered Level Switch
The IntelliPoint Loop Powered Two Wire provides a capacitance probe level switch with current output and “On-Board” self-diagnostics to ensure reliability and level sensing elements for a wide variety of temperatures, pressures, and materials.
-
product
C Series Current Output Module
The C Series Current Output Module features up to eight channels of simultaneous analog output. You can choose between enclosed and non-enclosed modules. Additionally, the C Series Current Output Module has built-in open-loop detection. This detection generates an interrupt in software when an open loop is detected, zeros outputs to ensure safety, and avoids driving actuators at system power-on. The C Series Current Output Module requires an external power supply and includes a channel-to-earth ground double isolation barrier for safety and noise immunity.The C Series Current Output Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
product
High Current Transformers
High Current Transformer is designed to elevate and check the temperature of the conductors at high current levels, in order to simulate the current loading conditions found in electrical circuits. High Current Transformer is designed as an open type transformer that uses the test object as its secondary coil or has 1 or 2-turn self secondary winding. The conductors cores' temperature depends on the short-circuit high current caused by the test object. According to the current going through the test object, the test temperature of the conductor will change. The loop temperature is measured by a thermocouple probe which is directly connected to conductor.
-
product
4-port Serial Interface, Modular, With/without Optical Isolation, 3.3V/5V, With 9-pin Connectors
APCI-7500-3/4C
*This model has 4x 9-pin D-Sub male connectors on 2 brackets*RS232, RS422, RS485, 20 mA Current Loop*Modular structure through SI modules*With or without optical isolation*Mode configuration free for each port*128-byte FIFO-buffer, common interrupt*Transfer rate programmable up to 115,200 Baud*Option: up to 1 MBaud for RS485 and RS422*Automatic direction recognition for RS48*Mode: configurable RS232, RS422, RS485, 20 mA Current Loop (active, passive) with or without isolation (SI modules)