Filter Results By:
Products
Applications
Manufacturers
-
product
Optic Node With Amplifier
OX 755
Converts even weak Optic Signals to a high quality RF Signal. LED BAR Optic Level Display has been provided for ease of system maintenance. They are best suitable for Analog as well as Digital transmission to maintain BER, MER Characteristics.- High Quality Nodes cum Amplifier- Frequency 40 ~ 1000 MHz- Good Sensitivity of -11 dBm- RF O/P 110 dBµV at 0 dBm Optic I/P- High Voltage Surge Protection- LED Optic Level Display- Powder Coated Housing
-
product
Signal Conditioning System
28000
The Precision 28000 Signal Conditioning System makes it easy to manage a test with up to 256 channels of fully programmable transducer conditioning. Choose a mix of bridge, charge, IEPE w/TEDS, voltage (filter amplifier), strain, thermocouple, RTD/potentiometer, frequency, or other transducers. Self-tests traceable to NIST. 4, 8 and 16-slot rugged and transportable mainframes feature integrated cooling. Customize the 28000 for high-speed transient applications, static applications, or a combination of both.
-
product
Electrical Safety Testers
STW-9900 Series
* 500VA AC Test Capacity* 240 x 64 Ice Blue Dot Matrix LCD* Manual/Auto Mode* Function Key for Quick Selecting* High Intensity Flash for Caution & Status Indication* Safety Interlock Function* Zero Crossing Turn-on Operation* Zero Crossing Turn-on Operation* True RMS Current Measurement * High Resolution : 1μA for Measuring Current, 2V for Setting Voltage* PWM Switching Amplifier to Enhance the Power Efficiency and Reliable Testing* Max. 100 Memory Block for Test Condition (Step) Setting. And Each Step can be Named Individually* Remote Terminal on the Front Panel for“Start”and“Stop” Control by External* Interface: RS-232C, USB Devise, Signal I/O and GP-IB (Option: OPT.1)
-
product
ADC Drivers Fully Differential Amplifiers
Differential amplifiers allow the process of single-ended input to complementary differential outputs or differential inputs to differential outputs. These amplifiers feature two separate feedback loops to control the differential and common-mode output voltages. Analog Devices fully differential amplifiers are configured with a VOCM pin, which can be easily adjusted for setting output common-mode voltage. This provides a convenient solution when interfacing with analog-to-digital converters (ADCs). ADI also offers a series of differential receiver products that convert differential input signals to single ended output.
-
product
Single Channel High Voltage Linear Amplifier
F20A
The F20A is a general purpose broadband linear amplifier having a fixed amplification of 20 times and capable of bipolar high voltage output of ±150V. Any functiongenerator or arbitrary waveform generatoror any othe signal source with amplitude up to ±10 V can be used as an input device. The amplifier's output is linear from DC up to megahertz range. It can be used in a wide range of applications, for example to drive piezo actuators, MEMS, OLEDs, liquid crystals, etc.
-
product
Current Amplifiers
In order to achieve an extremely low noise performance very high gains were chosen, while nevertheless minimizing the associated bandwidth reduction.Thus, as a result of our sophisticated development efforts we can offer a professional "High-End" Current Amplifier line. The noise performance of our products surpasses by far that of conventionally designed OpAmp current-to-voltage converters at the corresponding bandwidth.
-
product
Engine Speed Control and Measurement (Test Set A)
MS 1100
*Checks the parameters such as current, voltage, speed, and turbine gas temperature of 804E and 811 engines Portable instrument*Testing of Automatic engine control system and after burner control system*Simulates the temperature signal derived from the engine TGT (Temperature Gas Turbine) thermocouples*Simulates the speed signal, NL (low pressure shaft speed signal) drive from the L.P shaft Probe*Indicates the current signal to the FCU solenoid derived from the engine control amplifier*Measure the TGT and NL simulated signal at static position*Measure the signal produced by the engine TGT thermocouples*Measure the NL signal produced by the LP shaft*Measure the NH (High-pressure shaft speed) signal produced by HP shaft*Indicates the solenoid current, produced by the engine control amplifier*Indicates the solenoid voltage, produced by the engine control amplifier*Used to test engine in both static and dynamic states
-
product
Amplifiers
Amplifiers are used to amplify the energy output of photodetectors as well as convert their electrical signal for a number of illumination measurement or spectroscopy applications. Amplifiers are digital systems that amplify the low electrical current transmitted by photodetectors to easily detectable levels. Amplifiers also convert photodetectors' electrical current into voltage so that their signal may be read by other digital devices. Amplifiers are indispensable for nearly any light measurement applications by greatly increasing the usability of a detector system.
-
product
Electrical Safety Testers
STW-9800 Series
* 200VA AC Test Capacity* 240 x 64 Ice Blue Dot Matrix LCD* Manual/Auto Mode* Function Key for Quick Selecting* High Intensity Flash for Caution & Status Indication* Safety Interlock Function* True RMS Current Measurement * High Resolution : 1μA for Measuring Current, 2V for Setting Voltage* PWM Switching Amplifier to Enhance the Power Efficiency and Reliable Testing* Max. 100 Memory Block for Test Condition (Step) Setting. And Each Step can be Named Individually* Remote Terminal on the Front Panel for“Start”and“Stop” Control by External* Interface: RS-232C, USB Devise, Signal I/O and GP-IB (Option: OPT.1)
-
product
UV TOCONs
SiC based UV sensor with integrated amplifier and 0 – 5 V voltage output. Measures intensities from 1.8pW/cm² up to 18W/cm². Spectral response for broadband UV or filtered for UVA, UVB, UVC or UV-Index. Also available for blue light (GaP chip) or visible light (Si chip) measurement. Available in TO5 housings or as miniature sensor probes (stainless steel or plastic). Special TOCONs for hydrogen flame sensing (TOCON_F) and for fire detection (TOCON_N) available. Also available for operating temperatures up to 120°C (standard is 85°C). Please learn more about the sglux TOCONs here: TOCON selection guide and here: TOCON User Guide.
-
product
Gated Integrator | Boxcar Averager
GIA100
Artifex Engineering GmbH & Co. KG
The GIA100 gated integrator employs dual monolithic switched integrators. When paired with a photodiode, the boxcar amplifier measures the energy of single optical pulses. The GIA100 design results in very low leakage error, charge injection error and pickup. The precision input stage may be configured for current or voltage inputs.
-
product
Magneto-Electric Rotation Detector
MP-981/AP-981
The MP-981 is a magneto-type detector using a hall element which is suitable for revolution (r/min) measurement from low speed to high speed.Magneto-type detectors use an internal hall element, a permanent magnet, DC amplifier, and voltage regulator and respond to flux, so that a rectangular wave form is derivable from much lower speed all the way though high speed.In addition, a signal indicator is provided in spite of the detector's compact design, making verification of operation and mounting position possible.Meanwhile, the AP-981 is the water and acid proof type, which conforms to Class ' of JIS C0920.
-
product
High Voltage Amplifier
HA-405
* 400Vp-p(±200V DC)* 400mAp-p(±200mA DC)* Bandwidth: ≦1MHz(200Vp-p) *Slew Rate: 500V/us *Gain(AMPL):0~90(10 Turn VR) *DC Offset: ≦0~±200V(10 Turn VR+SW) *Output Resistor: 50Ω *Microprocess Control Protection
-
product
Current Sensing
voltage-output, current-sensing amplifier family that integrates an internal shunt resistor to enable high-accuracy current measurements at common-mode voltages that can vary from 0 V to 36 V, independent of the supply voltage. The device is a bidirectional, low- or high-side current-shunt monitor that allows an external reference to be used to measure current flowing in both directions through the internal current-sensing resistor sensor. The integration of the precision current-sensing resistor provides calibration equivalent measurement accuracy with ultra-low temperature drift performance and ensures an optimized Kelvin layout for the sensing resistor is always obtained.
-
product
Low Noise Pre-Amplifiers
Low Noise Pre-Amplifier and companion external low noise amplifier (LNA) are used to amplify low level microwave signals. The Pre-Amplifier contains an AC/DC power supply, internal low noise amplifier, and a bias tee to source a DC bias voltage on the RF input connector.To overcome cable loss between the test antenna and the Pre-Amplifier assembly, a remote low noise amplifier (LNA) is mounted directly onto the 10 GHz antenna. A bias tee inside the Pre-Amplifier chassis powers the remote LNA through the coax cable interconnecting the pre-amplifier and the 10 GHz test antenna.
-
product
Unipolar High Voltage Linear Amplifier
P150
The P150 is a general purpose linear amplifier having a fixed amplification of 20 times and capable of unipolar high voltage output of +150V. Any functiongenerator or arbitrary waveform generatoror any othe signal source with amplitude up to +10 V can be used as an input device. The amplification can be set to x15 (or other value) on request.
-
product
Rad-Hard Analog ICs
ST's wide range of rad-hard QML-V qualified analog ICs covers analog-to-digital converters (ADC) and digital-to-analog converters (DAC) for telemetry, instrumentation and imaging applications. Our portfolio also includes rad-hard op amps, high-speed differential amplifiers up to 1 GHz, shunt voltage references and comparators to ensure a complete solution for signal conditioning, referencing and data conversion.
-
product
Optical Detector
LG-9200
The LG-9200 is a non-contact type optical detector which emits red visible light and detects the reflected light from the rotating shaft. The reflection mark is used for the detection by affixing it on the rotating shaft. It enables detection at an angle. (reflective mark: HT-011 by Ono Sokki)The LG-9200 has a built-in compact amplifier and outputs the square wave (voltage) after waveform shaping.With a compact and light weight body, performances are upgraded compared to the previous model LG-916.(LG-9200 detection distance: up to 40 mm, response speed: up to 40 m/s)
-
product
Panel-mounted Power Amplifier(Hardware In The Loop Testing)
PA60Bi
PA60Bi is the panel-mounted power amplifier, which can produce 3-phase current, with maximum RMS phase current of 60A and maximum output power of 800VA, and 4-phase voltage, with maximum RMS phase voltage of 120V and maximum output power of 60VA.
-
product
Dual Channel High Voltage Linear Amplifier
A400D
This unit contains two independent A400 amplifiers that share common ground reference and power supply.
-
product
Basic Quad K-Type Analog Thermocouple Amplifier
SEN-30103-K1
Analog thermocouple amplifier board based on the AD849x from Analog Devices (successor of the AD597). This quad-channel thermocouple board converts the very low voltage signal from a thermocouple to a highly-linear, 0.005V/C output with either 0V or 1.245V offset (both configurations stocked) while removing unwanted noise from the signal. Many supply and output configurations are available with this board, though the PCB was designed with Arduino in mind. Specifically, the output header will plug directly into a standard Arduino Uno or Mega, with a pin-for-pin match for power supply, ground and analog outputs. With a 5V Arduino, temperatures from 0C to 1,000C are possible with the 0V offset board and -249C to 750C with the 1.245V offset board. If using a 3.3V microcontroller (Due, etc), the board must be supplied with no more than 3.3V to avoid damaging the microcontroller. Temperature measurement range is dependent on the supply voltage. It is possible to supply the board with higher voltages to allow temperature measurement over the entire operating range of the K-Type and J-Type thermocouples, allowing use with more capable data acquisition equipment.
-
product
RF Conducted Immunity Test System
RFCI61000-4-6
RFCI61000-4-6 RF Conducted Immunity Test System is an automatic test system which is for the conduction sensitivity testing, it is fully meets IEC61000-4-6.2006, ISO11452-4, GB/T17626.6-2008 and GTB152B-CS114 etc standards. RFCI61000-4-6 internal source and broadband power amplifier can be generated 3 voltage test levels: 1v, 3v and 10v, and has the function of the real detect output level. It has two operation software which is calibration software and test software. When measuring, the signal is in 1 KHZ sine wave amplitude modulation system (80%) to simulate the actual harassment, and can through the coupling/decoupling network (CDN or electromagnetic clamp) to make the harassment signal coupled to the device.
-
product
Amplifier Modules Band Specific
Modules are usually smaller and are usually part of systems. You supply your own DC voltage, make the connections and supply your own DC supply. Modules are available with or without heatsinks and fans. Amplifiers Modules are available in both Broadband and Band-Specific frequencies. Modular design concepts save time and money, and are lightweight, reliable, cost-effective solutions. We are well-known in the industry for successfully adapting our amplifiers or custom designing new solutions to suit each unique project. Please refer to our Adapted & Custom Design Solutions link to begin formulating your performance objectives and other criteria.
-
product
Lock-In Voltage Preamplifier
SR552
Stanford Research Systems, Inc.
The SR552 Voltage Preamplifier is designed to work with SRS lock-in amplifiers, providing gain where it is needed most?right at the experiment. The preamplifier minimizes noise and pickup in the connecting lines and can reduce measurement time in noise-limited experiments.
-
product
High Speed High Voltage Amplifier
WMA-300
The WMA-300 is a high voltage, wide bandwidth laboratory amplifier. Its high output voltage, current and wide bandwidth have been designed to serve the needs of a wide variety of high-tech experiments. The WMA-300 can be used for MEMS actuation, EO-modulators, PZT (piezo) positioners, ultrasonics, and many other applications. Two WMA-300 amplifiers and a WMA-IB-HS phase inverter - buffer can be used to double the output voltage.
-
product
Portable Power Amplifier
PA30Bip-H
PA30Bip-H portable power amplifier is designed with linear amplifier principle. It is very light portable solution with three channels of current output and four channels of voltage output.
-
product
High Voltage Op Amplifiers ≥12V
High supply voltage op amps are used in systems that demand the widest dynamic range with the best signal-to-noise ratio. Engineers turn to Analog Devices for high voltage amplifiers that deliver industry-leading performance. Increasingly, new high voltage amplifiers also offer features to improve system performance, cost, and robustness while easing the complexity of system design. New features include integrated input overvoltage protection (OVP), on-chip electromagnetic interference (EMI) filtering, higher electrostatic discharge (ESD) immunity, and greater resistance to latch-up in both powered and unpowered operations.
-
product
Operational Amplifier
Op Amp Series
The amplifier is capable of operating at supply voltages from 0.9V to 3V with specified specs at 1V and 1.8V single supply.The input common mode range extends to both power supply rails without the offset glitch and input bias current phase reversal inherent to most rail to rail input amplifiers.
-
product
PXI Voltage Amplifier 10K Ohm, D Type
41-650-011
A 5 channel voltage amplifier ideal for increasing the output voltage from other PXI modules, enabling users to easily generate the signal voltages commonly required in applications such as automotive test.
-
product
Voltage Controlled Oscillators
Teledyne Microwave Solutions (TMS) offers Voltage Controlled Oscillators (VCOs) utilizing bipolar transistors & silicon varactors over the frequency range of 40 MHz to 18GHz. Many of the VCO designs incorporate internal filtering, regulation & amplifiers to meet total system requirements in a small integrated package. Additionally, our hermetic hybrid designs can be screened to the most demanding military and space applications.