Filter Results By:
Products
Applications
Manufacturers
Safety Jacks
Socket whose insulating jacket meets safety standards.
-
product
Power Control
Educated Design & Development, Inc.
As a general purpose dual-voltage isolation transformer for step-up (120 to 240 VAC), step-down (240 to 120 VAC), or straight 1:1 isolation (120 to 120 VAC or 240 to 240 VAC). Models with a suffix "UC" are provided with a safety jack for access to the transformer secondary center tap (connected to the transformer center tap only in the 240 VAC output setting). This connection may be used in conjunction with a Dielectric Voltage Withstand test.
-
product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
779521-01
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
product
IEC61032 Test Probe Pin
CX-112
Shenzhen Chuangxin Instruments Co., Ltd.
1. Jointed test finger probe (Figure 2 / Test Probe B / IEC 61032)This is a precision probe made in accordance with all IEC standards. Examples are IEC 61032, 60950, 61010 and 60601; and it is also used for Canadian and USA standards. It features a palm simulator and a restricted joint movement, which simulates the characteristics of the human hand. The finger is made of stainless steel and the rest of the instrument is Delrin®. Handle is designed to accept either a banana jack or a force gauge.It is no longer necessary to have a separate probe for the medical safety standard. This one probe will meet all the different requirements that are in the IEC standards.
-
product
sbRIO-9237, Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
781209-01
Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The sbRIO‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the sbRIO‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools. Non-enclosed modules are designed for OEM applications.
-
product
Magnetizer
340B
The Model 300-series magnetizers are designed to handle a variety of magnetizing applications and materials, from small Alnico parts to large blocks of neodymium-iron. Each of these magnetizers feature patented ECS (Electronic Capacitance Switching) technology, which allows the user to change the capacitance of the unit through the front panel. By setting the charging voltage and capacitance of the magnetizer properly, the user can then scale the output energy of the unit to match the magnetizing fixture being used. The 300-series magnetizers also includes a peak current meter, which automatically captures the peak current of the magnetizing pulse once it occurs. A safety circuit internally discharges the capacitor banks if mains power is removed from the magnetizer or if the cabinet is opened during operation. When connected to a suitable magnetizing fixture, the magnetizer is able to disable its front panel controls if the fixture overheats. Other features include a lockout keyswitch and a current sense output jack (this connects to an oscilliscope for viewing of the magnetizing pulse). All 300-series magnetizers can be modified for computer control, photocell trigger, or autocharge operation.
-
product
Air Force
Alpha 4314 AF
4314AF introduces an added safety feature that prevents the possibility of having the charging adapter connected while using the instrument for measurements. A 6-pin Mil-Spec circular connector on the front panel of the 4314AF replaces the four-terminal banana jacks and the battery charger jack. Four of the front panel connector pins are used to mate with the measurement adapter cable and the other two pins are for the battery charging cable adapter. By using separate adapter cables for measurements and charging of the batteries, it ensures that the charge circuit cannot be activated at the same time as measurements are being made.
-
product
sbRIO-9237, Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
781028-01
Non-Enclosed, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The sbRIO‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the sbRIO‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools. Non-enclosed modules are designed for OEM applications.
-
product
High Voltage Switching Systems
HXV Series
HXV products are high voltage systems intened for Hi-pot / IR or High voltage switching. They can be configured to drive from 32 to 128 switch points per chassis and can be configured as multiplexer (1xN) or Matrix (NxM) configurations. Stand HXV chassis are used for signals up to 5000 VAC rms ( 7400 V peak ) and can carry up to 5 amps of current. Custom systems can be built up to 25KV. Most of the modules used in these systems are 1xN multiplexers or 2x4 matrix modules that can be combined to form larger multiplexers or matrices. Connector options for standard HXV include 5 way banaba jacks / binding posts, Shrouded Banana Jacks or SHV ( High voltage BNC) if you need to use a high voltage cable with a grounded shield for safety applications. Control options include 10/100BaseT Ethernet LAN, RS232, GPIB or optional manual control. Standard HXV systems use high voltage reed relays. Custom HXV systems up to 25KV use application specific relays and connectors from a variety of vendors based on required specifications.
-
product
Deluxe DMM w/Amp Shutters
582
*Huge 2 inch LCD Display, easy to see from across the room *Display is backlit for use in Dark Spaces *Amp Shutters prevent mistaken operation, improve safety and saves fuses by blocking unused amp jacks! *Great Meter for Electrical Trouble Shooting *11 Test Functions, 33 Test Ranges *Measures Temp in Both F and C, Probe Included *Desireable 20 Amp Test Range *Modern Design, the Protective Holster is Built-In *Data Hold *Carrying case, Test leads, Temp probe, Instructions and Battery included
-
product
Magnetizer
330B
The Model 300-series magnetizers are designed to handle a variety of magnetizing applications and materials, from small Alnico parts to large blocks of neodymium-iron. Each of these magnetizers feature patented ECS (Electronic Capacitance Switching) technology, which allows the user to change the capacitance of the unit through the front panel. By setting the charging voltage and capacitance of the magnetizer properly, the user can then scale the output energy of the unit to match the magnetizing fixture being used. The 300-series magnetizers also includes a peak current meter, which automatically captures the peak current of the magnetizing pulse once it occurs. A safety circuit internally discharges the capacitor banks if mains power is removed from the magnetizer or if the cabinet is opened during operation. When connected to a suitable magnetizing fixture, the magnetizer is able to disable its front panel controls if the fixture overheats. Other features include a lockout keyswitch and a current sense output jack (this connects to an oscilliscope for viewing of the magnetizing pulse). All 300-series magnetizers can be modified for computer control, photocell trigger, or autocharge operation.
-
product
Magnetizer
350B
The Model 300-series magnetizers are designed to handle a variety of magnetizing applications and materials, from small Alnico parts to large blocks of neodymium-iron. Each of these magnetizers feature patented ECS (Electronic Capacitance Switching) technology, which allows the user to change the capacitance of the unit through the front panel. By setting the charging voltage and capacitance of the magnetizer properly, the user can then scale the output energy of the unit to match the magnetizing fixture being used. The 300-series magnetizers also includes a peak current meter, which automatically captures the peak current of the magnetizing pulse once it occurs. A safety circuit internally discharges the capacitor banks if mains power is removed from the magnetizer or if the cabinet is opened during operation. When connected to a suitable magnetizing fixture, the magnetizer is able to disable its front panel controls if the fixture overheats. Other features include a lockout keyswitch and a current sense output jack (this connects to an oscilliscope for viewing of the magnetizing pulse). All 300-series magnetizers can be modified for computer control, photocell trigger, or autocharge operation.
-
product
Magnetizer
345B
The Model 300-series magnetizers are designed to handle a variety of magnetizing applications and materials, from small Alnico parts to large blocks of neodymium-iron. Each of these magnetizers feature patented ECS (Electronic Capacitance Switching) technology, which allows the user to change the capacitance of the unit through the front panel. By setting the charging voltage and capacitance of the magnetizer properly, the user can then scale the output energy of the unit to match the magnetizing fixture being used. The 300-series magnetizers also includes a peak current meter, which automatically captures the peak current of the magnetizing pulse once it occurs. A safety circuit internally discharges the capacitor banks if mains power is removed from the magnetizer or if the cabinet is opened during operation. When connected to a suitable magnetizing fixture, the magnetizer is able to disable its front panel controls if the fixture overheats. Other features include a lockout keyswitch and a current sense output jack (this connects to an oscilliscope for viewing of the magnetizing pulse). All 300-series magnetizers can be modified for computer control, photocell trigger, or autocharge operation.
-
product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
780264-02
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
product
NI-9237, 50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module
780264-01
50 kS/s/channel, Bridge Analog Input, 4-Channel C Series Strain/Bridge Input Module - The NI‑9237 includes all the signal conditioning required to power and measure up to four bridge-based sensors simultaneously. The module provides strain or load measurements with zero interchannel phase delay. It also has 60 VDC isolation and 1,000 Vrms transient isolation, providing high‑common‑mode noise rejection and increased safety. You can program the NI‑9237 for use with half-bridge and full-bridge sensors with built-in excitation. The four RJ50 jacks provide direct connectivity to most torque or load cells and offer custom cable solutions with minimal tools.
-
product
Safety
Chroma Systems Solutions, Inc.
The purpose of safety testing medical electronic equipment is to be sure that a device is safe from electrical hazards to the patient and caregivers. There are a number of UL, European and Canadian standards that serve as the ruling body on how medical products will be tested, one in particular, IEC60601 (the International Electrical Safety Standard for medical electronic equipment) is experiencing “global harmonization,” meaning it has been accepted and implemented around the world. The IEC60601 standard is mainly intended for product development where safety considerations must be taken into account early in the design phase of a product, however much of it is applied to production line testing since it is the only way for a manufacturer to be sure they are shipping safe product.
-
product
Safety Relays
SICK’s wide range of safety solutions - from single-channel emergency stop pushbuttons to safety laser scanners with PNP outputs - can be connected to safety relays. Safety relays are ideal for flexible and cost-effective machine integration. With SICK’s broad safety portfolio, you’ll find a solution for virtually any application.
-
product
Law Enforcement/Public Safety
Vehicular and Handheld antennas are available for communication, surveillance, signal DF, network repeaters and RF Jamming applications. A single omni or high gain directional ARA antenna may cover all cellular and/or Tetra communication bands and are compatible with all network technologies (GSM, CDMA, etc.). These wideband antennas replace the need for several single band antennas and are ideal for vehicular installations as well as handheld radio mounted applications. Permanent installations, quick deploy magnetic mounts or convenient pistol grips for radio location are available.
-
product
Functional Safety
More and more devices, machinery, plants and systems contain electrical, electronic and/or programmable electronic systems and components. Malfunctions – also in sub-systems and components – can lead to hazardous situations for people, machines and the environment. If these systems contribute to the safety of the product, it is necessary that they function correctly under all circumstances (including possible failures and malfunctions). One speaks of functional safety in this context.
-
product
RF Safety Monitoring
MVG EME Guard XS 40GHz
EME Guard XS 40 GHz has been specifically designed to cover the new 5G millimeter wave bands. This RF safety tool is important for keeping those working close to RF emitters safer. It is easy to use, continuously scanning electromagnetic waves, and alerts the user when acceptable pre-selected limits have been exceeded.
-
product
Safety Control Unit
SF-C21 Series
Panasonic Industrial Devices Sales Company of America
The safety control unit allows the user to connect and control various machine safety components. The SF-C10 series was specifically designed to connect and control Panasonic light curtains, while the SF-C21 safety control unit can be used for a variety of safety devices such as; safety switches, emergency switches, enable grip switches, safety beam sensors, safety scanners, and safety light curtains.
-
product
Chassis and Safety ICs
ST is a world-class supplier of IC smart power solutions for all the Chassis and Safety applications, ranging from passive safety, braking, vehicle dynamics and steering systems. Type of devices in ST portfolio are analog and mixed-signal ICs, integrating different functions such as supply modules, drivers for loads and actuators, diagnostic functions, system monitoring and communication interfaces.
-
product
Product Safety Testing
NCEE Labs is an A2LA Accredited product safety compliance testing lab. We specialize in compliance testing to US and harmonized international standards. NCEE Labs also offers NRTL testing services. With experienced product safety engineers, we provide expert assistance, whether evaluating early prototypes or assisting with aftermarket design changes.
-
product
Hipot & Safety Test
Chroma Systems Solutions, Inc.
Electrical safety tests to comply with IEC, UL, TUV, CSA, EN, and other electrical safety requirements.
-
product
Safety Tester
Designed to ensure safe operation of DUTs under various operating conditions and environment.
-
product
Safety Door Switch with Key
SG-B2 Series
Panasonic Industrial Devices Sales Company of America
These products feature key-based operation for worker protection in larger areas that could be hazardous. The SG-B2 Series Safety Door Switch and the SG-D1 Series Key Selector Switch can be used in tandem to add multiple layers of protection.
-
product
RF Safety Monitoring
FieldSENSE 60
The fieldSENSE 60 personal RF monitor has a proven track record of durability that works as hard as you do. fieldSENSE 60 is specifically designed with the RF climber in mind. Whether working in the nearfield of a broadcast system or in the far-field of a 5G system, exposure is correctly assessed and a warning is sounded, should the levels approach and exceed the OET65 and Safety Code 6 occupational limits. To ensure the device cannot be dropped off site, connect he device can be attached the included special harness-attachment mechanism. In the event of a warning while the monitor has fallen the buzzer is still within hearing range.
-
product
Electrical Safety Tester
Basic testing methods of Glow wire device> and UL 746A, IEC829, DIN695, VDE0471, the Glow wire tester ZRS-3H/ZRS-3HS is suitable for resistance to abnormal heat and fire test on lighting lamps, electronic products and household appliances. Adopting high-temperature coating spraying on steel structure and imported instrument display, with easy operation, stable performance the equipment is applicable to flame resistance tests of all levels of QC departments and corresponding enterprises.
-
product
Safety Relay Modules & Sensors
Using safety relay modules, you can reliably implement safety functions in machines and systems. They monitor signals from emergency stop buttons, light grids, and safety door switches, and initiate a safe state where necessary.
-
product
Safety Critical Miniature Relays
CU-V Series
The CU-V is a so called safety relay which is used in places where a safe separation between coil and contact circuit is required. The relay is, with the corresponding screw socket V12, according to CEE 15/2e edition, approved by KEMA, for application in gas fired installations.