Pulse Generators
Produce single or multiple volatage pulses for device verification and fault detection.
See Also: Pulse, Pulsers, Pulse Width, High Power Pulse Generators, High Voltage Pulse Generators, Programmable Pulse Generators
-
Product
F-S General Purpose Probes
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
Product
IMPATT Noise Generator CW & Pulse At W-band, 94 GHz :
-
The device consists of two modules, a cable that connects them, and a power cable. The first module (I) contains the power supply (AC 115 V), regime switch mechanism and a generator of a series of pulses. The second module (II) is the noise generator. Photo 1: Module I - Power Supply
-
Product
Pulsed IV
AURIGA 4850
-
Pulsed IV (current-voltage) measurements have emerged as the preferred method of capturing current-voltage characteristics of active devices such as field effect (FETs) and bipolar junction (BJTs) transistors.
-
Product
Alternate 2.64 (75.00) - 6.50 (184.00) General Purpose Probe
EPA-2G40-1
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
PXIe Multi-Channel Function Generator Module, 8-Channel
43-625-004
-
The 41-625-004 (PXI) and 43-625-004 (PXIe) are function generator modules that provide 8 channels in a single PXI/PXIe slot. They can generate sine waves to 300 kHz with 5.76 mHz frequency resolution referenced to the 10 MHz PXI clock. The output voltage range is up to +/-25 V in a 16-bit resolution. It also support PXI trigger functions allowing events from other instruments to initiate waveform generation or sweeps.
-
Product
Ethernet/LXI generatorNETBOX 16 Bit Arbitrary Waveform Generator - up to 125 MS/s on 4 Channels
DN2.656-04
-
The generatorNETBOX DN2.65x arbitrary waveform generators (AWG) is a general purpose multi-channel AWG with outstanding dynamic performance. The series includes LXI units with either four, eight or 16 synchronous channels. The large onboard memory can be segmented to replay different waveform sequences.
-
Product
Non-Linear Pulse Amplifiers
-
These amplifiers have fixed output amplitudes, and are DC-coupled. All models can drive 50 Ohms or higher.
-
Product
Generators
Vibration Shock
-
Software Vibration shock is used for testing specimen resistance to vibration impact. This software is a part of the software complex ZETLAB VIBRO, supplied together with vibration control systems ZET 017-U. The software enables generation of impacts with pre-set parameters and noise presence within a specified frequency range. The software is activated via ZETLAB control panel and VCS menu.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2F
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Pulse Air-Gun Ionizers
EC-G Series
-
Panasonic Industrial Devices Sales Company of America
With the new Pulse Air-Gun Ionizer from Panasonic, operators can comfortably neutralize static electricity while manually cleaning. The Pulse Air-Gun’s light-weight, ergonomic design combined with an oil and heat-resistant 2m cable makes it ideal for use at the production line.The Air-Gun Ionizer is equipped with a white LED on the front of the Gun to illuminate target objects. It has three air emission modes: long pulse, short pulse and continuous emission. Ionized air can be emitted at high pressure (range 0.05 to 0.50 MPa), neutralizing static charges and removing dust simultaneously and swiftly.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74B
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Waveform Generators
-
Drive your test systems forward with PXI instruments from Astronics. Small size, power-packed, and cost-effective, these waveform generators provide the perfect upgrade for your test bench.
-
Product
TSC157 Solar Panel Probe
TSC157
-
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 25Test Center (mil): 157Test Center (mm): 3.99Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,114Overall Length (mm): 28.30
-
Product
P2662B General Purpose Probes
-
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
Product
Pulse Current Generator Multi-Pulse Generator
-
Shanghai Guantu Technology Co., Ltd.
What is the difference between ordinary current and pulse current?The difference between ordinary current and pulse current: ordinary current is continuous and uninterrupted current.Pulse current is a current whose direction does not change and whose intensity changes periodically with time.
-
Product
Dual Channel Arbitrary Waveform Generator 9GS/s 8Bit, 4GS Mem 2CH 8 Markers AWG
P9082M
-
The Proteus P9082M, is a PXIe based, 9GS/s, dual channel arbitrary waveform generator offering technologically advanced options and configurations such as, a dual channel 2.7GS/s digitizer with 9GHz bandwidth, to transform the instrument to an arbitrary waveform transceiver. The P9082M offers industry leading performance Including an innovative task oriented programming, real time data streaming, fast feedback loop for environment dependent waveform generation and user customizable FPGA for application specific solutions.
-
Product
High-Power Pulsed Amplifiers
-
High power pulsed amplifiers are capable of providing over 1KW of peak power above 10GHz. These SWaP-optimized, high-reliability products have been designed to withstand the toughest environments. For custom requirements, Mercury leverages its proven building-block design approach to rapidly deliver a solid-state power amplifier (SSPA) for your application.
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4D
-
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
12GHz 16-Channel Signal Generator 19" 3U Rack Module
LS12916R
-
The LS12916R, 12GHz 16 channel RF Analog Signal Generator, offers industry leading performance, in a 3U, 19” space efficient, rack-mounted box. The LS12916R features 16 phase coherent channels, exceptionally fast switching speed, superior signal integrity and purity and all the necessary modulated signals for analog communication systems. With the highest channel density in the market the LS12916R offer the ideal solution for applications requiring high channel count at minimum space and cost.
-
Product
Pulsed SMU Systems
-
AMCAD Engineering has created professional, industry-proven pulsing technology for both pulsed-bias load pull (Pulsed Load Pull, PLP) and 50ohm transistor test applications. Systems come equipped with a mainframe controller which includes integrated power supplies and integrated input pulser with ±25V/200mA capability. The external output pulser module (probes, pulsers) is configured for 120V/30A pulsing.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1E
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Crown, Four Point, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0-Standard
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Alternate 1.30 (37.00) - 4.50 (128.00) General Purpose Probe
HPA-1B-1
-
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Neutron Pulse Monitor
Neuchrometer
-
The Neuchrometer provides all the advantages of Quaesta’s proven neutron pulse monitors including a Multichannel Analyzer, data logging, and digitally configurable parameters. The device integrates these features into a 1 inch diameter package and includes new list mode functionality with time stamping and source tagging for use in neutron coincidence counters and large arrays.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40G
-
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
Pulse Panel Meter
PPM
-
The Series PPM has a unique, rugged, NEMA 4X front panel design that makes it nearly impenetrable in typical applications. The weatherproof, UV resistant, large, dual line display allows for more information, making it easier to read and simpler to program. The intensity of the display can be adjusted allowing this meter to be utilized in dark rooms as well as outdoors, due to its sunlight readable display.
-
Product
High 4.00 (113.00) - 6.70 (190.00) General Purpose Probe
P2550-0-8
-
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
Frequency & Pulse Distribution
-
Timetech frequency distribution amplifiers and pulse distribution units.
-
Product
Keysight 32-Channel FormC/Form A General Purpose Switch for 34980A
34937A
-
The Keysight 34937A is a general-purpose switch module for the 34980A Multifunction Switch/Measure Unit. It has 28 independent single-pole, double-throw (SPDT) 1A relays and 4 single-pole, single-throw (Form A) 5A relays. This module is used to cycle power to products under test, control indicator and status lights, and to actuate external power relays and solenoids. The Form C channels are 300V, 1A contacts and can handle up to 60W, and the Form A channels are 30VDC/250VAC, 5A contacts and can handle up to 150W. Standard 50-pin Dsub connectors allow for use with standard cables, terminal blocks, or mass interconnect solutions.
-
Product
4-Axis Pulse Motion Controller
APM-104C
-
The AMP-104C is a cost-effective 4-axis motion controller card with a PCI Express® interface that can generate a pulse train up to 4.9MHz to control a motor. With more general purpose IOs and 4-channel encoder feedback input, the AMP-104C can be used for a multitude of scenarios or applications. As a motion controller, the AMP-104C provides non-symmetric acceleration and deceleration speed profile settings, T-curve and S-curve speed profile control, and selection of motion stop method. Also,changing speed on the fly with a single axis operation, linear Interpolation with any 2 axes, and simultaneously start/stop on multiple axes are also available.





























