Contamination
-
Product
Surface Contamination Monitors
-
Small-sized devices for measuring the ambient dose equivalent rate and the ambient dose equivalent of X-ray and gamma radiation, as well as measuring the flux density of beta particles (AT6130).
-
Product
Ionic Contamination Test Equipment
-
For manufacturers driven to deliver quality products, SCS Ionic Contamination Test Systems are the industry standard, delivering accuracy and performance in a range of configurations.
-
Product
Molecular Contamination
-
Ion mobility spectrometers detect and alert users to small concentrations and changes in airborne levels of chlorides, acids, amines, and ammonia-containing species.
-
Product
Contamination Monitors
-
Control of X-ray and gamma radiation personal dose equivalent.The dosimeter together with the PC reader and the software forms an efficient automatic system for staff radiation exposure control.
-
Product
Salt Contamination Meter
130
-
Key features of the Elcometer 130 Salt Contamination Meter include: Fast reading rate allows multiple conductivity tests to be completed efficiently Pressure plate ensures a constant and uniform pressure to paper Automatic detection of paper size and automatic adjustment of reading value USB and Bluetooth® data output to ElcoMaster® software Dust and water resistant rugged design equivalent to IP64 Automatic temperature compensation ensures accurate results Non-oxidising gold plated contacts ensures lifetime accuracy Stores up to 150,000 readings in 2,500 alpha numeric batches Fully portable hand-held, ergonomic design ideal for use in the field
-
Product
Ionic Contamination Test Systems
CM+ Series
-
The Contaminometer (CM+ Series) system was originally developed by Protonique, the business of industry guru Brian Ellis. They also featured in the early development programmes of "cleanliness measurement" carried out by the US Department of Defense at China Lake in the 1970s. Historically, International Standard IPC-J-STD001 stated that assemblies be cleaned to a value of <1.5µg/cm2 of NaCl equivalence. However, the new design is linked to the introduction of the new process control metric introduced by Gen3 Systems: Process Ionic Contamination Testing. The CM+ Series measure the amount of ionic contamination in accordance with all existing test methods, often referred to as ROSE testing, as well as the new PICT test.
-
Product
Surface Contamination Kit
138/2
-
The Elcometer 138/2 Surface Contamination Kit provides the user with a means for testing invisible surface contaminants including:pHchloride ionsironsalts
-
Product
Hot Blocks for Acid Digestion
QBlock Series
-
QBlock series provides wide selection to choose appropriate hot block to increase efficiency of digestion and through put. Teflon coated graphite block and enclosure provides ability to produce contamination free results. Modular approach for Commander, touch screen base temperature controller helps increase life span of system and provides total control over 4 QBlock simultaneously.
-
Product
Chloride Ion Test Kit for Water
134W
-
The Elcometer 134W is used to monitor recycled water (after it has been applied) to establish effectiveness of salt removal, this test is ideal for testing the salt contamination in wash water and blast water.
-
Product
Laboratory Ferrography
T2FM 500
-
The SpectroT2FM 500 Analytical Ferrography Laboratory is a complete analytical system for the separation and interpretation of wear and contaminant particles in used lubricant oils, hydraulic fluids, coolants and fuels. It consists of the T2FM Ferrogram maker, a bichromatic microscope, video camera and image capture software.
-
Product
PXI Single 8 Channel Switch Simulator
40-485-021
Switch Module
Designed to simulate the operation of automotive switches where dirty contacts or leaking current can be expected from switch contamination. It allows automotive I/O devices to be tested for correct operation under adverse conditions.
-
Product
Application Specific LC Systems
Nexera Amino Acid Analysis System
-
Amino acid analysis occupies an important role in diverse fields such as food science and pharmaceutical manufacturing. Nexera Amino Acid Analysis System uses detection by post-column fluorescence derivatization, with o-phthalaldehyde (OPA)/N-acetylcysteine as the reaction reagents, to selectively and with high sensitivity quantitate the amino acids contained in samples with high levels of contaminants.
-
Product
EDX-FTIR Contaminant Finder/Material Inspector
EDXIR-Analysis Contaminant Finder/Material Inspector
-
EDXIR-Analysis software is specially designed to perform qualitative analysis using data acquired by an energy dispersive X-ray (EDX) fluorescence spectrometer and a Fourier transform infrared spectrophotometer (FTIR). This software is used to perform an integrated analysis of data from FTIR, which is excellent at the identification and qualification of organic compounds, and from EDX, which is excellent at the elementary analysis of metals, inorganic compounds and other content. It then pursues identification results and the degree of matching. it can also be used to perform EDX or FTIR data analysis on its own. The library used for data analysis (containing 485 data as standard) is original to Shimadzu, and was created through cooperation with water supply agencies and food manufacturers. Additional data can be registered to the library, as can image files and document files in PDF format. It is also effective for the linked storage of various types of data as electronic files.
-
Product
Surface Analysis and Materials Characterization Services
-
The Materials Characterization division of Evans Analytical Group is the leading global provider of surface analysis and materials characterization services. Our international network delivers world-class analytical services directly to you. EAG''s expertise in surface analysis, composition and contamination measurement, trace elemental analysis and microscopy can help you and your company meet your goals, no matter what high technology industry you work in.
-
Product
Slip Testing (Articulated Strut) (Mark II)
SG-P07MII
-
It's used to determine the slip resistance of footwear sole, heel or related materials against planar walkway surface or walkway surrogates under dry, wet or contaminated conditions.
-
Product
Sample Holder/Stocker For Contaminant Measurement
EDXIR-Holder
-
Measure the Samples Kept in the Holder with EDX and FTIR The Holder Can Be Used as the Sample Stocker after the Measurement
-
Product
1TB NAND SATA Drive
XMC-554C
-
Curtiss-Wright Defense Solutions
The XMC-554C is a rugged, high performance, reliable and power-efficient NAND flash solid state drive (SSD) solution. The XMC-554C does not have any moving parts, providing significantly lower power consumption and an order of magnitude improvement in reliability in environments with vibration and contaminants, compared to traditional rotating hard disk drives (HDD).
-
Product
Metal Detection Pipeline System for Vacuum Fillers
HDS
-
Metal detection systems for sausage manufacture and inspection of high viscosity liquids. The maximum capacity to detect all metal contaminants combined with stable on-line performance. Full stainless steel construction and sealing standards up to IP69K make HDS pipeline detectors suitable for the harshest meat processing environments.
-
Product
AEROTRAK™ Handheld Particle Counters
9306
-
The TSI AEROTRAK™ Handheld Particle Counters offer the most features and flexibility for customers interested in low cost and versatile particle contamination monitoring.
-
Product
Cleaning
Air Knives
-
Fraser Anti-Static Techniques Ltd
Produce fast-moving ionised air which can neutralise static electricity and remove contaminants.
-
Product
PicoClean MTP/MPO One-Click Cleaner
MTC-12
-
Shanghai Fibretool Technology Co.,Ltd.
Many troubles in optical communications equipment are caused by contamination on the optical connector end face.The MPO/MTP connector cleaner, employs microfibers designed specifically for optical connectors to remove even the smallest contamination not visible to the naked eye.
-
Product
AOI Handlings System
-
The AOI handling system is a compact facility with various test units. Via an ionization cleaning station the ceramics are transferred to the contacting station. There, the resistance values of the substrates are tested with a rigid needle adapter. Afterward, the ceramics are further conveyed to the three (optionally four) AOI test stations (for automatic optical inspection) and are tested for cracks, unevenness, faulty imprints, contamination, etc. The poorly evaluated ceramics arrive at a review station where the operator can assess and evaluate the errors on the monitor. If the operator is uncertain about a fault, the ceramic in question can be positioned under the microscope position and inspected by eye. Poorly defined ceramics are marked accordingly with an ink pen.
-
Product
Biosafety Testing
-
Biological products derived from mammalian cell lines pose an inherent risk for the introduction of microbial or viral contaminants. In addition, the manufacturing process or product itself may introduce impurities that must be characterized.
-
Product
Automated Wear Debris Analyzer
LaserNet 200 Series
-
The LaserNet 200 Series allows reliability professionals to quickly and easily assess machinery health in just minutes. By testing only a few milliliters of fluid, users see a complete picture of machine wear and particulate contamination. This enables the user to determine filtration efficiency, the type of wear mode occurring, and the change in ferrous debris concentration, for maintenance action.
-
Product
Fan Type Ionizer
ER-F
-
Panasonic Industrial Devices Sales Company of America
With a compact size of 150 x 166 x 62mm and a fan of 120mm in diameter, the ER-F Fan Type Ionizer belongs to the leading class of compact Fan Type Ionizers. The system employs a high-frequency AC method and boasts a +/-2kV discharge output voltage that discharges electrostatic contaminated objects quickly and safely. Louvers for long distance and wide area applications are shipped with the Ionizers. Standard fan types for faster charge removal times and low-volume types for discharging small parts or film are available.
-
Product
Fourier Transform Infrared Spectrophotometer
IRTracer-100
-
This system achieves excellent sensitivity with an SN ratio of 60,000:1, high resolution at 0.25 cm-1, and high-speed scanning capable of 20 spectra/second. The performance of medium and higher end models is supported by high reliability including advanced dynamic alignment and an interferometer with a dehumidifier. This is compatible with applications active in a variety of circumstances, with a library of approximately 12,000 spectra and data analysis programs for contaminant analysis, and time course and rapid scan programs for reaction tracking.
-
Product
Plastic Analyzer
-
The Plastic Analyzer method package includes an FTIR spectral library for plastics degraded by UV rays and heat. Utilizing searches of this library demonstrates its effectiveness in the analysis of unknown samples that are difficult to identify with standard libraries. Examples include plastics degraded by exposure to UV rays as well as contaminants and defective items altered by heating.
-
Product
Cleanroom Testing
-
MicroStat Laboratories -R.E.T.S.
We utilize the relevant test methods and standards set forth by the ESD Association, ANSI, ASTM, NFPA, IEST, IEC, ISO, or our clients’ in-house specifications. ESD testing is performed in-house; other testing can be arranged through sub-contractors with interpretation of results performed by experienced contamination control experts..
-
Product
Flow Switches
-
Not susceptible to contamination and can be oriented in any pipe configuration make these flow switches for liquid or air maintenance free and reliable. Mechanical and electronic designs available
-
Product
Flexible Separators
-
The Parker flexible separators are a cost effective solution for the prevention of contamination into a hydraulic system





























