Measuring Receivers
measure radio signals.
-
Product
Receiver, G10, 10 Module, Keying Feature
310104317
-
The Receiver for the G10 is equipped with keying, a locking handle and nickel plated steel slides that engage up to 2,400 contact points. It allows high amount of I/O within a compact and rugged device.
-
Product
Precision Source / Measure Unit (1 Ch, 100 FA)
B2901B
-
The Keysight B2901B precision source / measure unit (SMU) is a 1-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
PXI Isolated Single Channel Voltage/Current Source, 100V
M9186A
-
The V/I source lets you source a voltage and measure the resultant current, or source a current and measure the resultant voltage. It consist of two separate amplifiers, denoted "low" and "high" that share a common output connection. The "low" amplifier provides voltages in the range of 16 volts at up to 200ma and the "high" amplifier provides voltages in the range of 100V at up to 20mA.
-
Product
Coherent Optical Receiver
IQRX
-
The IQRX is a “gold standard” coherent receiver for the measurement of coherent modulation formats such as QPSK, 64QAM and OFDM.Its high-bandwidth, low-noise architecture makes it ideal for high-quality, low-distortion coherent signal measurement.With two built-in lasers and convenient touchscreen LCD front panel control, the IQRX delivers quick and reliable measurements.
-
Product
Receiver, 9025, 25 Module, Slide Mount, Telescopic Handle - Right Side
310104477
-
The 9025 is a 25 module receiver designed to fit into a standard 19" rack. This model is equipped with a telescopic handle on the right side. This handle is designed to rest flush against the side of the receiver as a standard handle, or can be extended out to the right up to 3" to accommodate a larger ITA enclosure or other obstruction that may prevent normal handle operation/ engagement.As with the standard 9025, a microswitch is included. Mounting flanges and an instrument bracket are also included for slide mounting. A slide kit is required, but not included. See 9025 procedure sheet/ user manual for instructions on choosing the correct slide kit length for your test rack. *Please note: Consult procedure sheet/user manual for information regarding slight slide mechanism bracket protrusion downward into next U height on test rack on both sides of receiver.
-
Product
Source/Measure Unit for Functional Test, Multiple Ranges, 80 W, Double-wide
N6786A
-
Only Keysight`s N6780 Series SMUs let you visualize current drain from nA to A in one pass and one picture unlocking insights to deliver exceptional battery life.
-
Product
PXI Source And Measurement Unit Family
PXS840x
-
The PXS(e)840x is a high precision, high speed source and measurement unit, which is designed for automated high throughput testing.
-
Product
Receiver, 9050, 50 Module, for 36" Slide Mounting Kits only
310104483
-
This 50 module receiver is equipped with a locking handle to ensure proper ITA engagement. A standard integrated microswitch shuts off power when the ITA disengages from the receiver. This receiver is specially designed to work with the 36" slide kit p/n 310113500 (which is required, but not included) through the use of a longer instrument bracket.
-
Product
Receiver, I1, With Protective Cover
310128101
-
i1 accepts a single iCon module and allows a variety of signal, power and coaxial connections. A protective cover is included with the receiver. Other accessories, such as keying pin kits and strain relief, are available.
-
Product
Receiver, 9025, 25 Module, Slide Mount, Telescopic Handle - Left Side
310104498
-
The 9025 is a 25 module receiver designed to fit into a standard 19" rack. This model is equipped with a telescopic handle on the left side. This handle is designed to rest flush against the side of the receiver as a standard handle, or can be extended out to the left up to 3" to accommodate a larger ITA enclosure or other obstruction that may prevent normal handle operation/ engagement.As with the standard 9025, a microswitch is included. Mounting flanges and an instrument bracket are also included for slide mounting. A slide kit is required, but not included. See 9025 procedure sheet/ user manual for instructions on choosing the correct slide kit length for your test rack. *Please note: Consult procedure sheet/user manual for information regarding slight slide mechanism bracket protrusion downward into next U height on test rack on both sides of receiver.
-
Product
Two-Quadrant SMU For Battery Drain Analysis, 20 V
N6781A
-
The Keysight N6781A is a source / measure unit (SMU) designed specifically for the task of battery drain analysis. Whether the device under test (DUT) is an eBook reader, MP3 player, mobile phone, or pacemaker, the N6781A’s seamless measurement ranging, programmable output resistance, and auxiliary DVM combine the best set of advanced features on the market for battery drain analysis. When used with the 14585A Control and Analysis software, the N6781A becomes an even more powerful battery drain analysis solution, offering additional insights into your measurements. Learn more about the 14585A Control and Analysis software.
-
Product
Receiver, G10x, 15 Module
310104482
-
The adaptable G10x receiver integrates a wide variety of I/O options in various module configurations that allow engagment of up to 3,200 signal contacts. The G10x receiver also works with G10 ITAs and the G10x ITA for increased functionality.
-
Product
Receiver, 9050, 50 Module, for Slide Mounting
310104402
-
This 50 module receiver is designed to fit into a standard 19” rack. It is equipped with a locking handle to ensure proper ITA engagement. A standard integrated microswitch shuts off power when the ITA disengages from the receiver. This receiver is designed to work with a slide kit and includes mounting flanges and instrument brackets. A slide kit is required for use, but not included.
-
Product
Receiver, ICon, Reverse Module Configuration For ICon ITA Modules, With Protective Cover
310123103
-
Receiver, iCon, Reverse Module Configuration for iCon ITA Modules, with Protective Cover
-
Product
Remote Dynamic Receiver
E1708A
-
The Keysight E1708A uses an optical fiber to transport the laser beam from a remote sensor assembly to the electronics. This improves measurement accuracy and repeatability by enabling you to mount heat-producing electronics away from the measurement area. The fiber optic cable also provides increased mounting design flexibility and easier access to the receiver attenuation and squelch adjustments.
-
Product
High-Density Precision SMU (100 PA, 30 V)
PZ2130A
-
The Keysight PZ2130A is a high-channel density precision source / measure unit (SMU) with 5 channels per module that saves space at a low cost per channel for a wide range of applications requiring numerous precision power supplies. Its seamless current measurement ranging function eliminates the time it takes to change the range and expands the dynamic range to cover multiple measurement ranges, which reduces test duration. These capabilities make the PZ2130A suitable for applications that require numerous precision power supplies, such as semiconductor reliability tests and integrated circuit (IC) tests. The Keysight PX0107A low noise filter adapter lowers its voltage source noise level, which makes the PZ2130A suitable for noise sensitive applications such as quantum computing as well.
-
Product
Receiver, G12x, 18 Module, With 15" Platform For Tabletop
310104410
-
Receiver, G12x, 18 Module, with 15" Platform for Tabletop
-
Product
Receiver, G3, 500+ Amps, includes Dedicated 500+ Amp Module
310105172
-
Receiver, G3, 500+ Amps, includes Dedicated 500+ Amp Module.Contacts rated to 1500VDC for low duty test applications.Mating ITA 410105174. (NOT compatible with other VPC Solutions)
-
Product
IRIG Timecode Receiver and Generator
RG1
-
The RG1 Time Code receiver synchronizes to IRIG-A/B/G time codes and provides precise time in a memory register, for the host SBC.The IRIG output of the card can be used to synchronize other IRIG time code readers. Additionally, the RG1 includes a real-time clock (RTC) that may be used as a reference source for IRIG master applications, to free the system processor from the task of updating the master timer.
-
Product
PXIe-4145, 4-Channel, ±6 V, 500 mA Precision PXI Source Measure Unit
782435-01
-
PXIe, 4-Channel, ±6 V, 500 mA Precision PXI Source Measure Unit - The PXIe-4145 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. The fast sample rate of the PXIe-4145 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4145 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
Remote High Performance Receiver
E1709A
-
The measurement signal frequency changes as the stage velocity changes. The Keysight E1709A ensures minimal phase processing errors due to frequency changes. The receiver also provides immunity to errors induced by changes in measurement signal power that occur due to small pitch, roll and yaw movements during stage motion. These features help provide the most accurate measurements under system motion.
-
Product
Receiver, i2 Micro iCon, 168 Position, Unloaded, for Twin Female QuadraPaddle Contacts
310130107
-
This i2 Micro iCon receiver comes ready to load with twin female contacts (610 138 200)
-
Product
Receiver, G6, 6 Module, EMI
310104344
-
The G6 Receiver includes a keying feature, locking handle and nickel-plated steel slides that engage up to 1,440 signal contacts in a 6-module configuration- all in a compact and rugged design.This G6 model also includes EMI gasketing for EMI protection.
-
Product
Adapter Rails (for High Speed Inserts), i2MX, Receiver, 88 Pos, 11 Slot
510143001
-
Allows use of SIM VTAC patchcords in an i2MX receiver. Accommodates 11 single-slot inserts.
-
Product
Signal, Module, Receiver, QuadraPaddle, iCon Series, 160 Position, loaded w/ Twin Female Contacts and Round Posts
510160122
-
Fully Loaded with Twin Female Contacts and Round Posts (Adapter Pins) (p/n's 610138200 and 610138117).Primary mating module 510161101. (May mate with other ITA modules, as well.)
-
Product
PXIe Precision Source/Measure Unit, 1.25 MSa/s, 10 fA, 210 V, 315 mA
M9601A
-
M9601A PXIe precision SMU is the industry-first precision PXIe SMU enabling faster precise measurement from DC to 20 μs pulse up to 210 V/315 mA with the best-in-class 10 fA resolution and low noise.
-
Product
Module, Receiver, CASS, Signal, 800 Position, QuadraPaddle
510113151
-
Module, Receiver, CASS, Signal, 800 Position, QuadraPaddle.
-
Product
Signal / Micro Power/ Micro Coax, Module, Receiver, QuadraPaddle, iCon Series, 100/15 Position, loaded w/twin female contacts
510160112
-
This module comes fully loaded with twin female contacts (p/n 610138200), iCon modules mount from the rear of the iCon/i1 receiver allowing installation and removal of pre-wired cable blocks. Primary mating module 510161107. (May mate with other ITA modules, as well.)
-
Product
Signal, Module, Receiver, TriPaddle, 64 Position, w/ Right Angle Contacts
510104109
-
Primary mating module 510108101. (May mate with other ITA modules, as well.)
-
Product
PXIe-4144, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit
782432-01
-
PXIe, 4-Channel, ±6 V, 500 mA PXI Source Measure Unit - The PXIe-4144 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4144 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.