Total Harmonic Distortion
Is a measure of a signal's sum power of all harmonic components to the power of the fundamental frequency.
See Also: Distortion, Intermodulation Distortion, THD
-
Product
Ultra-Low Distortion Function Generator
DS360
-
Stanford Research Systems, Inc.
The performance of a low distortion analog source and the precision of direct digital synthesis (DDS) is combined in the DS360. With less than 0.001 % total harmonic distortion (THD), 25 ppm frequency accuracy, and a broad range of features including sweeps and bursts, the DS360 is the ideal source for audio frequency applications.
-
Product
LCD Power Meters
-
Accuracy ±0.1% F.S. Measuring and display ACV/ACA/Watt/Var/VA/Power Factor/Frequency/KWH/DM(Demand) Input measurement network can be selectives(1P2W/1P3W/3P3W/3P4W) CT rate/PT rate can be modified(1 to 9999) Measuring ACV/ACA total harmonic distortion(THD),up to 35th harmonic(optional) Two alarm control function (optional) Two pulse output function (optional) Digit RS-485 interface function (Optional)
-
Product
Adjustable High Frequency Reference Ballast
HCS-109A
-
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
Product
Power Quality Meter
Qualstik
-
The Qualstik Power Quality Meter has been developed specifically for measurement of four important items of power quality in the electric utility industry. These are Current, True Power Factor, Total Harmonic Distortion and the Direction of Current Flow.
-
Product
AC / DC Digital Power Analyzer
4016(800Vp,20Arms/200Ap)
-
To analyze AC/DC power source, it requires a lot of parameters. Such as voltage(V), current(A), power factor(PF), Total Harmonic Distortion(THD), Crest Factor(CF), Inrush current, etc. To meet power saving regulation, the standby power measurement must be done. In this video I will show you how to operate this Prodigit Power Analyzer 4016. Furthermore, I explain what the parameter's meaning.
-
Product
G.fast Transformers
-
Our line of G.fast transformers are the preferred choice of engineers seeking the most reliable, functional isolation transformers for G.fast transmission. These compact transformers deliver excellent longitudinal balance and total harmonic distortion performance.
-
Product
Digital Power Meter (High Accuracy Model)
LS2050
-
LS2050 digital power meter is a new generation intelligent product which adopts digital sampling technology to analysis of the waveform. It has the following features: • Three windows digital display which reduces reading error, intuitive and convenient • Adopts high speed MCU and high precision A/D to control and measurement • All measured data as virtual value, also suit to signal waveform distortion • Fast test • Equipped with RS232 communicate function, can use upper computer software to carry on remote operation, control and read corresponding data, the test data and waveform could be displayed in the PC, Chinese and English operation interface, high intelligent instrument • This instrument provides two kinds of method to calculate total harmonic distortion (THD), IEC and CSA.
-
Product
Operational Amplifiers
-
Operational amplifiers from ams are ideally suited to audio applications. These CMOS devices are available as single, quad or differential amps. They feature good common-mode rejection, have low input bias currents, good gain bandwidth, low total harmonic distortion and an excellent rail-to-rail output-drive capability of 200mA peak.
-
Product
AC-DC Power Supply Solutions
-
Advanced Conversion Technology, Inc
From single to three phase inputs, 60 Hz or 400 Hz, ACT can provide you with a design to meet your demanding applications. ACT can also provide designs that incorporate an active PFC front end, single and three phase, which provides less than 3% total current harmonic distortion.
-
Product
128 KS/s, 24-Bit, 8-Ch PCIE Card For IEPE Sound And Vibration
PCIE-1803
Sound and Vibration
8 simultaneously sampled analog inputs, up to 128 kS/s24-bit resolution ADCs with -102 dB total harmonic distortion plus noise (THD+N)
-
Product
4-Ch, 24-Bit, 192 KS/s USB 3.0 I/O Module For Sound And Vibration (With AO And Tachometer)
USB-5801
Sound and Vibration
USB 3.0 SuperSpeed and daisy chainable by built-in USB hub4x simultaneously sampled analog inputs, up to 192 kS/s24-bit resolution ADCs with -94 dB total harmonic distortion plus noise (THD+N)Built-in anti-aliasing filter2 mA integrated electronic piezoelectric (IEPE) excitation currents2 analog outputs with update rate up to 192 kS/s24-bit resolution DACs with -90 dB total harmonic distortion plus noise (THD+N)2 tachometer inputs for period or frequency measurement4-ch isolated digital input and 4-ch isolated digital output
-
Product
Power Quality Analyzer
-
Power quality analyzer is a product carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, man-machine operation and concise and comprehensive test instrument. It is easy to use, large LCD screen display, high resolution, interface in both Chinese and English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc; Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data.
-
Product
mAEStro Audio Analog to Digital Converter
-
The mAEStro AADC-100 accepts balanced stereo analog audio inputs and converts them into a single digital bit stream in compliance with the AES/EBU (AES3) and S/PDIF digital audio standards. It generates 24-bit values and uses 128 times over-sampling for extremely accurate and linear analog to digital conversion, as well as offering a high dynamic range with exceptionally low total harmonic distortion and noise.
-
Product
AC Power Source, Frequency Converter
BL1350 Series
-
Behlman's BL1350 AC Power Supply / Frequency Converter / Inverter, requires just 3.5" of rack height, and weighs as low as 45 pounds, yet it delivers 1350 VA of quality AC power. In the BL 1350, you'll find the quality features you expect from Behlman, fully adjustable frequency and voltage, total harmonic distortion of less than 0.5%, high efficiency, plus excellent line and load regulation.
-
Product
Power Analyzers & Wattmeters
-
Measurements International Ltd.
Direct Replacement for 2010A Wattmeter in the AccuLoss® Loss Measurement Systems, Basic Power Accuracy < 0.005 %, 10 Current Ranges, 2 Voltage Ranges, Line-and-Line and Line-to-Ground Voltage Measurements, Full Power Factor Range, Complete Waveform Analysis, Total Harmonic Distortion Analysis, Phasor Analytical Representation.
-
Product
Waveguide Harmonic Mixers (smart mixer), 60 to 90 GHz
M1970E
Harmonic Mixer
The Keysight M1970E 60 to 90 GHz waveguide harmonic mixer is an un-preselected mixer that will extend the operating frequency range of the N9030A PXA, N9020A MXA,and N9010A EXA signal analyzers up to 90 GHz. Smart features are embedded to help you to greatly simplify your overall test setup and improve the DANL and TOI of your test system. Go smart with harmonic mixing for your millimeter-wave applications.
-
Product
Waveguide Harmonic Mixer, 40 to 60 GHz
11970U
Harmonic Mixer
The Keysight 11970U waveguide mixer is a general-purpose harmonic mixer employing a dual-diode design to achieve flat frequency response and low conversion loss. These are achieved without external dc bias or tuning stubs. Manual operation and computer-controlled hardware operation are simplified because mixer bias and tuning adjustment are not required.
-
Product
Waveguide Harmonic Mixer, 50 to 75 GHz
11970V
Harmonic Mixer
The Keysight 11970V waveguide mixer is a general-purpose harmonic mixer employing a dual-diode design to achieve flat frequency response and low conversion loss. These are achieved without external dc bias or tuning stubs. Manual operation and computer-controlled hardware operation are simplified because mixer bias and tuning adjustment are not required.
-
Product
Distortion Analyzer
SINAD
-
SINAD utilizes the latest in Digital Signal Processing (DSP) technology to accurately measure several key performance characteristics of radio receivers by analyzing the spectral content of a received audio signal.
-
Product
Waveguide Harmonic Mixers (Smart Mixers), 55/60 to 90 GHz
M1971E
Harmonic Mixer
Keysight M1971E 55/60 to 90 GHz waveguide harmonic mixers is an un-preselected mixer provides a complete solution for wideband millimeter-wave signal analysis of more than 2 GHz with X-Series signal analyzers. Smart features are embedded to help you to greatly simplify your overall test setup and improve the DANL and TOI of your test system. Go smart with harmonic mixing for your millimeter-wave applications.
-
Product
Intermodulation Distortion Measurements
S96087B
-
Easily set up and calibrate swept intermodulation distortion measurements (IMD) measurements using the S96087B software application with the ENA
-
Product
Harmonic Trap Inductors
-
Osborne designs harmonic trap inductors to work in conjunction with capacitors in power systems to prevent specific line-frequency harmonics from flowing back to the power source (point of common connection). This power quality design approach prevents harmonic currents from flowing to the main facility power system and/or to the utility power system. The Osborne system also reduces unnecessary power losses and power-system pollution.
-
Product
Harmonics and Flicker Testers
-
complied standards and features of the KHA1000 (dedicated for single phase), is equipped for the harmonic and flicker compliance test exceeding 16A of the single-phase and three-phase equipment. With this unit alone, you can take highly accurate simultaneous three-phase measurements up to 40A/phase*.
-
Product
Robotic Total Stations
SPS620 And SPS720
-
Keep it accurate, but keep it simple. The SPS620 and SPS720 are perfect for one-person operation on smaller site operations and work on structures such as bridges or culverts, offering very high accuracy and reliability for construction site positioning, stakeout and measurement.
-
Product
Smart Harmonic Mixers
-
These smart mixers use a simple USB plug-and-play connection which can automatically configure the signal analyzer for the specific mixer connected, including downloading conversion loss data and automatically compensate for local oscillator path loss. Therefore, it provides you with the most efficient test setup, shortening the overall start up operations with better performance with its embedded smart features when used with Keysight EXA, PXA, MXA, and UXA signal analyzers.
-
Product
Total Sulfur Analyzer
Model T108
-
Teledyne Advanced Pollution Instrumentation
The Model T108 Total Sulfur analyzer is designed to measure mixed sulfur impurities, collectively referred to as Total Sulfides, in air or carbon dioxide gas. Since there is no scrubber in the system, the instrument reading is the sum of the oxidized sulfur compounds and SO2.The Model T108 consists of a modified Model T100 SO2 analyzer with special software and a Model 501TS high temperature thermal oxidizer. Sulfur compounds are heated as they pass through the converter and oxidized into SO2. When analyzing CO2, which generally contains no oxygen, approximately 6% O2 is added to the sample before entering the converter. This dilution is corrected in the calibration procedure.
-
Product
Condenser for Harmonic Protection
FMLF 7%
-
Lifasa - International Capacitors, SA
These LIFASA capacitors are designed to be connected in series with INR or INA reactors, and thus form a harmonic filter tuned to a frequency of 189 Hz (lower than the first harmonic present in the network). The nominal powers of the filters indicated in the table are obtained by being connected to the reactors.
-
Product
ACCUplace Dot Distortion Target
AP-DD Series
-
All machine vision lenses will show some type of distortion. Minimizing or correcting that distortion is crucial in most applications. The ACCUplace Dot Distortion target is designed to detect the presence of both barrel/pincushion distortion as well as alignment distortion that causes the keystone effect. The precise amount of distortion is determined from an array of precisely placed dots in a regular array. The results can be used to correct for any distortion that occurs within the optical system. The AP-DD is offered on three standard substrates; Chrome on Glass (CG) Opal (OP) and Photo Paper (RM).





























