Power Calibrators
Verify power measuring instruments accuracy.
-
Product
Advanced Power System - DC Power Supply, 20 V, 100 A, 2000 W
N6971A
-
The N6971A is designed for automated test equipment (ATE) applications where high performance is critical.
-
Product
10 MHz – 18 GHz USB Power Sensor
U2000H
-
U2000H USB Power Sensor measures average power over the frequency range 10 MHz to 18 GHz and power range -50 dBm to +30 dBm.
-
Product
PLTS Measurement And Calibration
N19303B
-
The new Physical Layer Test System (PLTS) 2024 is the industry standard for signal integrity measurements and data post‑processing high-speed interconnects, such as cables, backplanes, PCBs, and connectors. Signal integrity laboratories worldwide have benefited from the power of PLTS in the R&D prototype test phase.
-
Product
Bench Power Supply, Adjustable, 4 Output, 0 V, 32 V, 0 A, 3 A
T3PS43203
-
Bench Power Supply, Adjustable, 4 Output, 0 V, 32 V, 0 A, 3 A.
-
Product
IR Calibration Instruments
-
Bodkin Design & Engineering, llc
We offer a line of comprehensive solutions to address all of your thermal calibration needs. From bench-top differential sources with .01° C resolution for experiment calibration to built-in OEM devices for on-the-fly thermal reference, Bodkin Design and Engineering and IRBlackbody have the right blackbody for you.
-
Product
AC Calibration Standard
1U647-001
-
The 1U647-001 is a low cost calibration standard used to determine if a 1U632-100 or a 1U663-100 DMU requires factory calibration. Its portability makes it ideal for field-testing. The standard generates signals that simulate the aircraft’s resolvers, rotary variable transformers (RVTs), and linear variable displacement transformers (LVDTs). The unit also generates a pulse width modulated (PWM) signal, and routes the output of an ARINC 429 source to the different DMU input channels. The calibration standard connects directly to the DMU and replaces the output signals of an active extender card. Discrete switch settings simplify testing. The unit is housed in a rugged aluminum case.
-
Product
Partial Discharge Calibrator
TPK-H
-
The high voltage-resistant Partial Discharge calibrator is used to determine the correction factor in the PD test circui.
-
Product
Mini Power, Contact, Receiver, 65 Amp, 8 AWG
610116112
-
Primary mating contact 610115124. (May mate with other ITA contacts, as well.)Mini Power contacts carry up to 65 amperes continuous current. Maximum resistance is 1 Milliohms.
-
Product
Instrument Transformer Calibrators
MRL 22
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Automatic measure of contact resistance. True 4 terminal measurement. μP operated, automatically saves results.
-
Product
Pressure/Vacuum Calibrators
-
Compact, completely self-contained unit designed for calibrating and testing pressure gauges, transducers, pressure switches, and other pressure-sensitive instruments up to 2,000 psi with an accuracy of ±0.25% of full scale.
-
Product
Differential Sensor, Wide Dynamic Range, 100 MHz
CX1105A
-
The CX1105A ultra-low noise differential sensor is a dedicated accessory for the CX3300 series and enables dynamic current measurements from 1 μA to 100 A under up to 100 MHz bandwidth with existing shunt resistors on your test board.
-
Product
Power Sensor and SNS Noise Source Cables (3 m/10 feet)
11730B
-
The Keysight 11730 series power sensor cables are used with the 8480 and E-series power sensors (except the E9320 family of peak and average sensors). These cables are designed to reduce RFI effects on low power readings with an improved shielding design in the cable itself. Cables may be ordered individually or in pairs in any combination desired for single and dual-channel measurements.
-
Product
PICMG® 2.11 47-Pin Hot-Swap Redundant 3U CompactPCI® 8HP 250 W Power Module
cPS-H325/48
-
- PICMG® 2.11 CompactPCI® Power Interface compliant- 3U CompactPCI® 8HP form factor- PICMG® 2.11 47-pin CompactPCI® in-rack power module interface- 250 W DC output- Active PFC (Power Factor Correction) meets IEC1000-
-
Product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (f)
85563A
-
Combines an open, short, and load standard in a compact unit that is easy to handle and lightweight
-
Product
Pressure Calibrators
-
AMETEK Sensors, Test & Calibration
Our pressure calibrators offer a wide variety of features, accuracies, and pressure ranges. Included are intrinsically safe percent of reading calibrators, reference data recorders, wide-range dual sensor calibrators, and calibrators with built in pressure pumps. Many of our calibrators also offer current measurement, voltage measurement, 24 volt loop power supplies, and even complete systems with pressure pumps and calibration software. In many cases, one handheld calibrator can replace multiple instruments, reducing ongoing recalibration and maintenance costs.
-
Product
Legendary Calibration Oscillator
LCO Series 3.5” x 2.5” x 0.6”
-
*Connectorized Package *Low Output Power Variation (±0.05 dB)*Output Power to +10 dBm Available *Optional Internal Reference
-
Product
Acoustic Emission Calibrator
-
AE calibrator is similar to a simple signal generator, it can generate a variety of controlled waveform signal, different types, different amplitude and different frequency. It can help users calibrate acoustic emission detection equipment before acoustic emission detection.
-
Product
Triple Output DC Power Supply, 30V/6A (2x) & 5V/3A; 375W
U8031A
-
Keysight now extends its range of basic DC power supplies to offer 375watt power range, making it an ideal power source alternative in electronics manufacturing, research and development as well as the education sector. The U8031A, basic DC power supply, is a manual triple-output power supply with sequencing capability. With this function, users can generate output sequences with minimal programming skills. Each power supply is also built with excellent load regulation and clean output noise for continued stability. With these and many other features, you get a solid and reliable triple-output power supply at an unsurpassed performance.
-
Product
Power Supply Series
HMP2000
-
The R&S®HMP DC Power supplies are primarily designed for industrial use. With two or three output channels and up to 10 A output current, these rugged instruments are ideal for a wide variety of applications. They offer high efficiency with low residual ripple and many protection functions.
-
Product
Pressure Calibration
-
Trescal provides full Pressure Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Pressure Calibration services can be delivered at your site or at our lab. Accreditations for our pressure calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
Calibration Solutions
Options & Accessories
-
SPEKTRA Schwingungstechnik und Akustik GmbH Dresden
In its standard configuration, every CS18 calibration system is optimized for a specific practical application. Its performance, however, can be extended by means of optional extras. On customer's demand, dedicated options can be compiled and offered with the system.
-
Product
Power Device Analyzer / Curve Tracer
B1505A
-
The Keysight B1505A Power Device Analyzer / Curve Tracer is the only single box solution available with the capability to characterize high power devices from the sub-picoamp level up to 10 kV and 1500 A. These capabilities allow evaluation of novel new device such as IGBT and materials such as GaN and SiC. The B1505A supports a variety of modules: high voltage SMU (HVSMU), high current SMU (HCSMU), ultra high current (UHC) module, ultra high voltage (UHV) module and high voltage medium current (HVMC) module. The B1505A also supports: high-power SMU (1 A/200 V), medium-power SMU (100 mA/100 V) ,medium-current SMU (1 A/30V pulsed, 100 mA/30V DC) and a multi-frequency capacitance measurement unit (1 kHz 5 MHz). Its ten-slot modular mainframe allows you to configure the B1505A to suit your measurement needs.
-
Product
Programmable Switching DC Power Supply 1 Output, 0-250V, 0-4A, 360W
T3PS250041P
-
Programmable Switching DC Power Supply 1 Output, 0-250V, 0-4A, 360W.
-
Product
Calibrator Module
CAP CAL
-
The purpose of CAP-CAL is to check the correctness of Tan Delta and Capacitance of TD 5000 and TDX 5000. The calibrator includes an extremely high accuracy high voltage capacitor, which comes with a certificate issued by ISA - Altanova Group lab.
-
Product
Calibration
-
During the recent years we have made scientific investigations regarding calibration procedures, which have been published and integrated in the European and International standards. The calibration of antennas and field probes in Seibersdorf is done on the reference open area test site, in three different TEM-Cells and in the fully anechoic chamber. The open area test site is one of the best in Europe. Since 1996 we are the accredited calibration laboratory according to Akkreditierung Austria 0612 for antennas and field probes.
-
Product
Gauges & Calibrators
-
Ralston Instruments' gauges and calibrators are born from decades of experience working with technicians, project managers and facilities teams responsible for maintaining metrology instruments.
-
Product
Acoustic Calibrator
CAL250
-
The Larson Davis Model CAL250 is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment.
-
Product
VDI Erickson PM5B MM–Wave Power Meter with W-Band Sensor, Optional Tapers to 1.5 THz
N1913PM5B
-
N1913PM5B is a Virginia Diodes, Inc./Erickson PM5B calorimetric mm-wave power meter, with a W-Band sensor for power measurement over a frequency range of 75-110 GHz.
-
Product
Calibration Benches
-
CalBench is a custom built work station for industrial test facilities and calibration laboratories. A wide range of modules for calibration of electrical, pressure, temperature, and loop are available. Further modules and extras such as power supplies, oscilloscopes, and counters can also be integrated. CalBench provides the versatile solution to multi product calibration that meets the highest industry standards.