RCD
Residual Current Device
-
Product
RCD Loop Line
-
Digital measuring instrument for RCD testing with Loop and Line resistance measurement also without tripping the RCD.
-
Product
Digital RCD Testers
-
Used to detect whether the RCD in the circuit can be triggered normally.
-
Product
RCD Testers
-
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2710 is a residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE). RCD testers let a fault current flow and thus determine at which fault current the RCD triggers. The tripping time is also measured. These two parameters, tripping current and tripping time, are the safety-relevant parameters of an RCD. The various selectable test currents and characteristics that can be set with this device make the PeakTech 2710 the ideal companion for every electrician.
-
Product
Socket Tester with RCD Tripping
-
Shanghai Beha Electronics Co., Ltd.
*Mains wiring polarity check.*ELCB/RCD testing.*Measuring ear for line current.*Measuring ear for leakage current.*Helps calculate insulation resistance.*Helps calculate power consumption.*Helps fault finding of standing earth fault.*Fused main adapter.*Appliance testing (with the ad of a clamp meter).
-
Product
Recorder Carrier Device
RCD
-
The RCD is a carrier signal demodulator for SCADA and Fault Data Recording. the RCD demodulates the carrier to indicate the presence of a relative level of a singal
-
Product
Multifunction Installation Tester
COMBI519
-
COMBI519 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
Product
Socket Tester c/w Buzzer
DL1092
-
Clear visual and audible indication RCD test of 30 mA RCD (max time 300 ms) Touch voltage to check for extraneous voltage on earth Compact, durable design in compliance with BS EN 61010
-
Product
180V-260V AC Socket Tester With RCD Test (For UK)
1943
-
Peaceful Thriving Enterprise Co Ltd
*With UKCA Approval.*Test for 180~260VAC circuit.*LED indicators & Digital display.*30mA leakage current measurement.*RCD Test.I*t can perform self test after plug-in ( Voltage sould be above 180V ).*Detect faulty wiring status in 3 wire receptacle.*This socket tester will give LED indication as well if the main voltage is below 200V or above 260V.*Earth loop impedance test.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 11W*Frequency: 50Hz
-
Product
Single-Functional Testers
3122
-
The MI 3122 SMARTEC Z Line-Loop / RCD is designed specifically for live circuit testing. The instrument contains integrated characteristics of fuses and RCDs for the evaluation of test results. The online voltage monitoring system allows the operator to control what is happening on three simultaneous voltages in real-time. The bright red and green PASS / FAIL lights and help screens for each measurement make the handling of the instrument easy and clear. All the results can be quickly saved on the instrument and then downloaded via the optional A 1291 EuroLink PRO or A 1290 EuroLink PRO Plus software for evaluation and professional report generation after testing.
-
Product
Multifunction Tester
EASYTEST
-
EASYTEST carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
Product
Multifunction Testers
1662
-
The Fluke 1662 installation tester gives you Fluke reliability and all the basic testing power you need for day-in, day-out installation testing. It tests to all local regulations and is easy and intuitive to use. Additional helpful features like the On/Off switchable auto-start for RCD and loop test, and self-test save time and give you more confidence in your results.
-
Product
Resistive & Capacitive AC Load Bank
RCD
-
RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test.
-
Product
CombiVolt™ 1 Voltage/Continuity Tester
DL6780
-
Testing of AC/ DC voltages from 12 to 690 V AC/DC Continuity testing with optical and acoustic indication Automatic switching between voltage and continuity Phase rotation test system Single pole phase indication Fully compliant with GS38 Fully operational voltage indication even when batteries are discharged Will not trip any RCD when testing across Live and Earth Single pole detection when L2 probe connected above 100V
-
Product
Multifunction Installation Testers
-
Shanghai Beha Electronics Co., Ltd.
Loop impedance and prospective short circuit current measurement• Line impedance and prospective short circuit current measurement• Earth loop resistance in TT-systems• Rotary field test• RCD measurements (contact voltage, trip time, trip current - ramp method)• RCD analysis for test of all RCD parameters • Low Ohm and continuity measurement • Insulation measurement up to 1000V (suitable for 690 V industrial mains systems)• Earth resistance measurement with probes and clamp adapters• Voltage and frequency measurement • Current measurement with clamp adapters(optional)• Power and energy measurements• Harmonics measurement for voltage and current upto the 21st harmonics
-
Product
PAT Check Box
369A910
-
The only check box to provide comprehensive verification of 17th Edition and PAT test equipment. The Powercheck tests for full earth continuity, insulation, resistance, RCD trip time, RCD trip current, touch current and flash test verification.
-
Product
PAT and Installation Verification Unit
PowerCheck 1557
-
The PowerCheck 1557 is a comprehensive PAT and installation verification checkbox. It carries out ongoing performance checks to ensure accurate measurement between calibration intervals. Fully tests Earth Continuity, Insulation Resistance, RCD Trip Time, RCD Trip Current, Loop, PE Conductor Current, Touch Current and Flash tests.
-
Product
Multifunction Electrical Installations Meter
MPI-520
-
The MPI-520 multifunction meter is dedicated to perform diagnosis of electrical installation according to IEC 61557 standards. Digital meter MPI-520 is designed to measure impedance of a short cicuit loop also without triggering RCD, parameters of RCD, insulation resistance, earthing resistance, continuity and also for phase sequence testing. Furthermore to measure and logging of AC voltage and current, frequency and power.Wide range of standard accessories enable to perform all necessary measurements and safety test. Highly professional portable multifunction meter with memory of measured parameters.
-
Product
230V AC Socket Tester With RCD Test (For UK)
1944
-
Peaceful Thriving Enterprise Co Ltd
*With UKCA Approval.*Test for 230VAC circuits.*Neon indicators.*RCD Test.*30mA leakage current measurement.*Detect faulty wiring status in 3 wire receptacle.*Various combinations of 3 neon idnicators tell if wiring is OK or 6 possible faulty conditions.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 1.5W*Frequency: 50Hz
-
Product
AC Load Bank (Resistive/Capacitive)
K-1000 Resistive/Capacitive
-
Kongter Test & Measurement Co., Limited
A RCD (resistive/capacitive) generator load bank is non-linear load bank. The electronic and non-linear loads simulated by capacitive load banks are typical of the Telecommunications, Computer or Uninterruptible Power Supply (UPS) Industries.
-
Product
240V Socket Tester Check Plug
CP501
-
The most popular socket tester available - detects 28 fault conditions.
A quick and easy way to ensure that 13A sockets are correctly wired, indicated by 3 bright long life LEDs.
Wiring faults are indicated by one or more of the LEDs failing to illuminate, with the pattern of lit LEDs indicating the type of fault detected. This fail-safe system means that any LED not lit indicates a fault. The robust ABS housing has a sculpted shape for easy removal and there is a look up chart on the tester for quick fault diagnosis.
The plug induces less than 5mA of earth leakage, well below RCD trip thresholds.
-
Product
Voltage & Continuity Testers
-
Our range of CombiVolt voltage testers are designed to measure AC/DC voltages and continuity. Most models provide LED indication, an audible tone or a combination of both while others have a digital display to give an exact reading, all testers have a non RCD Trip feature
-
Product
Multifunctional testers
MI 3152 EurotestXC
-
MI 3152 EurotestXC is an instrument from the new generation of Metrel’s multifunctional measuring instruments. The already well known functions like complete installation safety testing according to IEC/EN 61557 and AUTO SEQUENCE testing of TN, TT and IT earthing systems are managed by a completely new user interface based on large colour touch screen display. A wide range of functions is included: from on-line voltage monitoring, phase sequence testing, varistor testing, earth resistance measurement, illuminance measurement and TRMS current measurement up to RCD tests, line and loop impedance tests, specific earth resistance measurements as well as ISFL measurements and the IMD tests.
-
Product
Socket Outlet Tester
-
Using the new Testavit Schuki 1 LCD and 3 LCD, specialists easily check to see if sockets, cable drums or connecting cables are correctly connected in 230 V installations. Due to three LEDs, the connection status can be quickly and clearly determined. In addition, through the finger contact, it can be tested to see whether an impermissible, high contact voltage is applied at the protective earth connection. In addition, using the Testavit Schuki 1 LCD, a 30 mA FI circuit breaker (RCD) can be triggered via a pushbutton.
-
Product
SMD Testers
-
Is a miniaturized and integrated utility model measuring instrument, which can automatically identify components such as resistance, capacitance, diode, etc., with LED, voltage regulator, DCV, on-off and battery power measurement functions. SMD resistance, capacitance, diode (RCD) parameter measurement, is a good helper for electronics factories and electronics maintenance.
-
Product
Multifunction Instrument
COMBI521EV
-
COMBI521EV is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards. Being a combined verification instrument, COMBI521EV also carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
Product
Multifunction Installation Tester
ProInstall-75-UK
-
The Beha-Amprobe ProInstall-75-UK, with new advanced features, is the perfect installation testing tool for verifying the safety of electrical installations in domestic, commercial, and industrial applications. Ensure that fixed wiring is correctly installed and compliant with IEC 60364, HD 384 requirements and BS7671 17th Edition wiring regulation meeting local requirements. The ProInstall-75-UK is efficient to use by allowing the user to measure loop impedance without tripping RCDs, eliminating the need to bypass them.
-
Product
Socket Tester
1945
-
Peaceful Thriving Enterprise Co Ltd
This is a portable 220VAC socket tester to inspect the wiring conditions. The tester also features current variation for simulation of different leaking current. With the current variation, technician is able to test the condition of Ground Fault Circuit Interrupter (GFCI) / Residual Current Device (RCD) easily.
-
Product
Multifunction Tester
COMBI521
-
COMBI521 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
Product
Multi Function Testers
-
Kyoritsu Electrical Instruments Works, Ltd.
Live circuit warning LED:Immediate illumination of a warning lamp if the circuit under test is live Auto Discharge:Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing Integral overload protection on internal continuity and insulation test circuitry Autoranging 500V DC test voltage for insulation tests 200mA short circuit current on continuity ranges Loop and RCD Testing Wiring connection check LED''s:Immediate indication if wiring of circuit under test is correct Overheat Protection:Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement Supply Voltage Indication:Can display supply voltage value in loop impedance mode Low Current Loop Impedance Test:Short duration low test current will prevent tripping of many passive RCDs
-
Product
Electric Shock Protection Analysis
-
60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel