RCD
Residual Current Device
-
Product
Digital RCD Testers
-
Used to detect whether the RCD in the circuit can be triggered normally.
-
Product
Socket Tester with RCD Tripping
-
Shanghai Beha Electronics Co., Ltd.
*Mains wiring polarity check.*ELCB/RCD testing.*Measuring ear for line current.*Measuring ear for leakage current.*Helps calculate insulation resistance.*Helps calculate power consumption.*Helps fault finding of standing earth fault.*Fused main adapter.*Appliance testing (with the ad of a clamp meter).
-
Product
RCD/LOOP/PAT Testers
-
Kyoritsu Electrical Instruments Works, Ltd.
Custom microprocessor controlled for highest accuracy and reliability. 3 LEDs for checking correct wiring status. 0 and 180 degree phase angle switch permits quick tests and consistent readings. Digital read-out of tripping time. Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings. Large custom digital display readout. Visual indication of reversed phase and neutral wiring at socket. Designed to IP54 Rating. Complies with IEC 61557 Test of a large kind of RCD''''s: Standard, Selective, AC and A (DC sensitive breakers)
-
Product
Resistive & Capacitive AC Load Bank
RCD
-
RCD AC load banks are used to test the REAL working condition of UPS, rectifier, inverter and etc who are loaded by non-linear or electronic load with non-constant resistance such as computer, networking equipments and etc. Through the accurate detection of its output and power quality, users could avoid the inadequate loading capacity or cause pollution to power grid, so as to guarantee supply security. JUNXY RCD load banks leading power factor loads are created to debug power supply system parameters such as its crest factor test.
-
Product
Recorder Carrier Device
RCD
-
The RCD is a carrier signal demodulator for SCADA and Fault Data Recording. the RCD demodulates the carrier to indicate the presence of a relative level of a singal
-
Product
Socket Tester c/w Buzzer
DL1092
-
Clear visual and audible indication RCD test of 30 mA RCD (max time 300 ms) Touch voltage to check for extraneous voltage on earth Compact, durable design in compliance with BS EN 61010
-
Product
PAT Check Box
369A910
-
The only check box to provide comprehensive verification of 17th Edition and PAT test equipment. The Powercheck tests for full earth continuity, insulation, resistance, RCD trip time, RCD trip current, touch current and flash test verification.
-
Product
Multi Function Testers
-
Kyoritsu Electrical Instruments Works, Ltd.
Live circuit warning LED:Immediate illumination of a warning lamp if the circuit under test is live Auto Discharge:Allows fast and safe discharge of electrical energy stored in capacitive circuits following testing Integral overload protection on internal continuity and insulation test circuitry Autoranging 500V DC test voltage for insulation tests 200mA short circuit current on continuity ranges Loop and RCD Testing Wiring connection check LED''s:Immediate indication if wiring of circuit under test is correct Overheat Protection:Rapid detection of overheating of internal circuitry,display of warning signal to user and automatic halting of measurement Supply Voltage Indication:Can display supply voltage value in loop impedance mode Low Current Loop Impedance Test:Short duration low test current will prevent tripping of many passive RCDs
-
Product
230V AC Socket Tester With RCD Test (For UK)
1944
-
Peaceful Thriving Enterprise Co Ltd
*With UKCA Approval.*Test for 230VAC circuits.*Neon indicators.*RCD Test.*30mA leakage current measurement.*Detect faulty wiring status in 3 wire receptacle.*Various combinations of 3 neon idnicators tell if wiring is OK or 6 possible faulty conditions.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 1.5W*Frequency: 50Hz
-
Product
Measuring Device for Testing the Effectiveness of Residual Current Protective Devices (RCD) According to DIN EN 61557-6 (VDE 0413-6)
-
PeakTech Prüf- und Messtechnik GmbH
A residual current tester, which is used to determine tripping currents and the tripping times of residual current circuit breakers, which are used in every new building according to current building regulations. Residual current circuit breakers are used for personal protection and switch off a circuit when a residual current is registered which flows off via the protective earth (PE).
-
Product
Installation Testers
-
Offers two models that verify the safety of electrical installations in residential, commercial and industrial applications. Has been developed to carry out the following safety measurements of electrical installations in accordance with EN 61557 and DIN VDE 0100: Insulation resistance, RCD tests, Low Ohm resistance, Earth ground resistance, Loop impedance, Phase sequence.
-
Product
EV Test Equipment
-
Di-LOG’s New EV Test Equipment Range which includes the DL9100 series MFT incorporates the DL9120 and DL9130EV with both products boasting DC capability, paving the way for a host of tests-specific to the *EV and PV sectors, mainly the ability to conduct a Type B (Pure DC) RCD test.
-
Product
240V Socket Tester Check Plug
CP501
-
The most popular socket tester available - detects 28 fault conditions.
A quick and easy way to ensure that 13A sockets are correctly wired, indicated by 3 bright long life LEDs.
Wiring faults are indicated by one or more of the LEDs failing to illuminate, with the pattern of lit LEDs indicating the type of fault detected. This fail-safe system means that any LED not lit indicates a fault. The robust ABS housing has a sculpted shape for easy removal and there is a look up chart on the tester for quick fault diagnosis.
The plug induces less than 5mA of earth leakage, well below RCD trip thresholds.
-
Product
Voltage & Continuity Testers
-
Our range of CombiVolt voltage testers are designed to measure AC/DC voltages and continuity. Most models provide LED indication, an audible tone or a combination of both while others have a digital display to give an exact reading, all testers have a non RCD Trip feature
-
Product
Multifunctional testers
MI 3100 SE EurotestEASI
-
MI 3100 SE EurotestEASI is a fast, accurate and easy to use multifunctional measuring instrument which performs a complete set of installation safety tests according to IEC/EN 61557. Besides, the MI 3100 SE EurotestEASI enables on-line voltage monitoring, phase sequence testing and earth resistance measurement. EurotestEASI is equipped with integrated characteristics of fuses and RCDs for PASS / FAIL evaluation of test results.
-
Product
Multifunction Tester
EASYTEST
-
EASYTEST carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
Product
Digital RCD Tester
1113 EL
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Very low consumption.● 50Hz and 60Hz operation.● Accurate digital readout of disconnection time.● Over temperature protection.● Over voltage protection.● Fuse protection.● Zero crossing circuitry permit testing at 0° or 180°.● Auto power off. ● Backlight function. ● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● Frequency measurement indication.
-
Product
CombiVolt™ 1 Voltage/Continuity Tester
DL6780
-
Testing of AC/ DC voltages from 12 to 690 V AC/DC Continuity testing with optical and acoustic indication Automatic switching between voltage and continuity Phase rotation test system Single pole phase indication Fully compliant with GS38 Fully operational voltage indication even when batteries are discharged Will not trip any RCD when testing across Live and Earth Single pole detection when L2 probe connected above 100V
-
Product
Digital ELCB (RCD) Tester
2820 EL
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Operating voltage 100-450V L-E.● Rated current 999mA, at 317V AC/50Hz.● Checks ELCB trip time and trip point (sensitivity).● Auto off and auto ranging.● Phase angle selection(0° / 180°).● Indicates tripping phase angle.● Impact resistant enclosure.● Over temperature shut-down.● Transient protection.● Suitable for heavy industrial use.● Fused.
-
Product
Multifunctional testers
MI 3125 BT EurotestCOMBO
-
The MI 3125BT EurotestCOMBO performs all the necessary tests for installation safety testing on TT and TN systems. The large graphic display with backlight offers easy reading of results, indications, measurement parameters and messages. Two LED Pass/Fail indicators are placed on both sides of the LCD. MI 3125BT EurotestCOMBO contains integrated characteristics of fuses and RCDs (including B type) for the evaluation of test results.
-
Product
Multifunction Installation Tester
ProInstall-75-UK
-
The Beha-Amprobe ProInstall-75-UK, with new advanced features, is the perfect installation testing tool for verifying the safety of electrical installations in domestic, commercial, and industrial applications. Ensure that fixed wiring is correctly installed and compliant with IEC 60364, HD 384 requirements and BS7671 17th Edition wiring regulation meeting local requirements. The ProInstall-75-UK is efficient to use by allowing the user to measure loop impedance without tripping RCDs, eliminating the need to bypass them.
-
Product
Electric Shock Protection Analysis
-
60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel
-
Product
Installation Tester
M74
-
M74 measures Overall earth resistance, tripping time of RCDs type AC, Insulation and Continuity of earth and equipotential conductors according to the laws in force in private electric installations.
-
Product
Digital ELCB (RCD) Tester
2712 EL
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 Lines × 16 characters LCD.● Very low consumption.● 50Hz and 60Hz operation.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Over temperature protection.● Over voltage protection.● Fuse protection.● Zero crossing circuitry permit testing at 0° or 180°.● Disconnection phase polarity shown on LCD display.● Auto off and off override.● Polarity trip indicator (positive or negative phase)● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● Frequency measurement indication.
-
Product
Digital ELCB (RCD) Tester
1812 EL
-
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2Lines × 16 Characters LCD.● Very low consumption.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity shown on LCD display.● Auto-off and off override.● Polarity Trip indicator (Positive of Negative Phase).● Wiring polarity indicator.● Measure voltage and frequency between Line and Earth before testing.
-
Product
Multifunction Installation Testers
-
Shanghai Beha Electronics Co., Ltd.
Loop impedance and prospective short circuit current measurement• Line impedance and prospective short circuit current measurement• Earth loop resistance in TT-systems• Rotary field test• RCD measurements (contact voltage, trip time, trip current - ramp method)• RCD analysis for test of all RCD parameters • Low Ohm and continuity measurement • Insulation measurement up to 1000V (suitable for 690 V industrial mains systems)• Earth resistance measurement with probes and clamp adapters• Voltage and frequency measurement • Current measurement with clamp adapters(optional)• Power and energy measurements• Harmonics measurement for voltage and current upto the 21st harmonics
-
Product
Multifunction Instrument
COMBI521EV
-
COMBI521EV is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards. Being a combined verification instrument, COMBI521EV also carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
Product
Multifunction Testers
1662
-
The Fluke 1662 installation tester gives you Fluke reliability and all the basic testing power you need for day-in, day-out installation testing. It tests to all local regulations and is easy and intuitive to use. Additional helpful features like the On/Off switchable auto-start for RCD and loop test, and self-test save time and give you more confidence in your results.
-
Product
AC Load Bank (Resistive/Capacitive)
K-1000 Resistive/Capacitive
-
Kongter Test & Measurement Co., Limited
A RCD (resistive/capacitive) generator load bank is non-linear load bank. The electronic and non-linear loads simulated by capacitive load banks are typical of the Telecommunications, Computer or Uninterruptible Power Supply (UPS) Industries.
-
Product
Multifunction Electrical Installations Meter
MPI-525
-
Possible measurementsShort-circuit loop measurement:*impedance measurement with 23 A current (44 A phase-to-phase) - short-circuit resistor R=10,*measurement range: 95...440 V, frequency 45...65 Hz,Short-circuit loop measurement with resolution 0,01, in distribution network without tiggering RCD (In30 mA):*automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,*additional UNI-Schuko plug for automatic measurement, AGT adapter for 3 phase network measurement.Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000 mA. (Type AC, A and B).Measurement of insulation resistance:*with test voltage 250 V, 500 V, 1000 V, 2500 V,*measurement range up to 10G,*automatic discharging after measurement,*automatic measurement of all resistences in 3,4,5-wire cables using optional adapter AUTO-ISO,*acoustic signals in 5 sec intervals for insulation resistance characteristic,*elapsing T1, T2, T3 times (0...600 s) form measurement of absorption coefficients (DAR, PI or Ab1, Ab2)*safety measurement - protection against overvoltage.Measurement of earthing resistance.Bi-directional testing of PE wire continuity using 200 mA current.*Autocalibration of test leads.