Current Comparators
-
Product
Portable Three-Phase Current Load
EE-120A-3
-
The Current Source is able to generate three-phase currents, synchronized with the service voltage, with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current is individually adjustable. The values of voltage, current, power, power factor, phase shift, THD and frequency are indicated on the LCD display.
-
Product
Current Protection Relay
-
The main earth fault protection relays in distributions systems, power stations & large manufacturing / processing plants can fail to detect a high impedance break down to earth causing hazard to human life & potential damage to plant & equipment. In these & other situations demanding extra sensitive earth fault protection, using solid state techniques, can be applied to detect earth currents down to 0.5% of the CT nominal current.
-
Product
DC/AC High Current Probe
698
-
Unit is designed for use with digital multimeters,lab scopes or graphing meters. With 1000 Amp capabiltiy, this instrument can be used to test starting and charging systems. It can even be used to test relative compression when used with your lab scope or graphing meter.
-
Product
Bulk Current Monitoring Probe
MP-50
-
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.
-
Product
Eddy Current Scanners
-
United Western Technologies Corp
a non-destructive testing (NDT) device that uses electromagnetic induction to detect surface and near-surface flaws in conductive materials.
-
Product
Current Probe
-
Vernier Software & Technology, LLC
Simplify your experimental setup with the Go Direct Current Probe. It connects wirelessly via Bluetooth® or wired via USB to your device. The wireless connection eliminates additional cables that can clutter the lab bench. Capture small currents like those produced by a magnet falling through a coil.
-
Product
Phase Meter Current Shunts
610 and 650
-
Clarke-Hess Communications Research
The Model 610 and 650 Current Shunts are specifically designed to operate with the Model 6000A Precision Phase Meter. These shunts are frequency tuned to have negligible phase shift (less than 5m) at 50/60Hz making them ideal for line frequency applications. They can also be idealized for other frequencies as specified by the user. Consult factory for details.
-
Product
Profiling Current Meter and Wave
SeaGuardII DCP Wave
-
The SeaGuardII DCP Wave is a 600kHz Doppler Current Profiler able to measure directional wave parameters and currents from a bottom mounted installation.The Acoustic Wave software 5759 used by the DCPS implements unique features to improve the wave measurement accuracy by optimizing the signal to noise ratio.Maximum deployment depth is 40m in normal scatter conditions. The Profiling Current Meter and Waveis available as a self-recording instrument. It can be easily integrated into a real-time system offering reliable two-way communication.
-
Product
Current Measurement
-
Measurements International Ltd.
No Stabilization Period, No Power Coefficient, No Temperature Coefficient, DC and AC Operation, 3000 A Max Current DC.
-
Product
Clamp type AC Current Sensor/for Leakage Current Measurements(ZCT Series)
ZCT-140
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Leakage current measurements of feeder*Compact size*AC 1mA~300A
-
Product
Leakage Current Clamp Mete
-
Basic functions:AC current:20mA resolution: 0.01mA, ± (2.5%, +5)200mA resolution: 0.1mA, ±(2.5%, +5)2A resolution: 1mA, ±(2.5%, +5)60A resolution: 100mA, ±(3%, +8)AC voltage: 600V, ±(0.8%, +5)DC voltage: 600V, ±(0.8%, +5)Special functions:Auto ranging Low battery display Data hold Auto power-off Over-load protection Input impedanceDC voltage measurement: ≥10MΩ Sampling frequency: 3 times/s Maximum display: 1999 Maximum distance between clamps: 30mm General characteristics:Product colors: iron-gray and redProduct net weight: approximately 136gLCD size: 25x36mmProduct size: 183x63x29mmPower: 2x1.5V, 7#Standard accessories: packing carton and handheld bag English user's manual and battery
-
Product
Leakage Current Alarm Signaler
MPU-1
-
MPU-1 is dedicated to control (measure) leakage current in AC, low and medium voltage power networks. It is designed to make measurements, which results define network's safety condition for leakage current. The device enables to set limit for maximum safe value of flowing leakage current and for values above this limit visual and sound alarm is activated.
-
Product
Low Current Probe 80A
695
-
Great tool for accurate measurement of low current. Use with your graphing meter or lab scope to view current waveforms on fuel injectors, fuel pumps, primary ignition coils and more. Also works very well with digital multimeters. Resolution of 10 milliamps is low enough for most parasitic drain testing. In addition, the clamp opening of 1/2 inch is large enough to clamp over most negative battery cables for those parasitic drain tests.
-
Product
Current Transformer Testers
-
Vanguard Instruments Company, Inc.
Performs CT excitation, current-ratio, polarity, and phase angle testsMeasures insulation resistance and winding resistance of the CT seconday windingsMeasures the CT's secondary burdenTest record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-commentsBuilt-in 4.5-inch wide thermal printerPlot Multiple Saturation CurvesStores up to 128 CT test plans and 140 test records internallyUSB, Bluetooth, and USB Flash drive interface
-
Product
Current Probe Calibrator
KSZ
-
PMK Mess- und Kommunikationstechnik GmbH
Since Current Probes are often exposed to hard working conditions, a performance check is recommendedbefore every use. These Current Probe Calibrators generate square wave pulses from 0.05 A to 1000 A with an accuracy better 1%. They qualify for calibration and adjustment of Current Probes.
-
Product
sbRIO-9227, Non-Enclosed, 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module
781118-01
-
Non-Enclosed, 50 kS/s/ch, 5 Arms, 24-Bit, 4-Channel C Series Current Input Module - The sbRIO‑9227 was designed to provide high-accuracy measurements to meet the demands of data acquisition and control applications. It includes built-in anti-aliasing filters. When used with a C Series Voltage Input Module, the sbRIO‑9227 can measure power and energy consumption for applications such as appliance and electronic device test. You can not only measure and meter current and power but also look at quality factors such as noise, frequency, and harmonics. Non-enclosed modules are designed for OEM applications.
-
Product
Current Probe For Multimeters
CP 1000
-
The CP 1000 current probe has been designed for use with multimeteres respectively for accurate, non-intrusive measurement of AC, DC and complex waveform currents.
-
Product
Clamp type AC Current Sensor/for Leakage Current Measurements(ZCT Series)
ZCT-30S
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Leakage current measurements of feeder*Ultra compact size*AC 1mA~100A
-
Product
Eddy Current Testing Instruments
INSITE HT & CT
-
The Zetec InSite HT and InSite CT are multi-channel, multi-frequency eddy current testing instruments. They are both designed to operate at full production line speeds in tough manufacturing environments. Both the InSite HT and InSite CT are available in 2, 4, and 8 channel versions.
-
Product
Current Transformers Test Set
-
Supreme Instrument Laboratories
The basic unit is sensitive magnetic comparator and also it incorporates electronic null detector to facilitate the balance. The reference Current 5A. or IA. obtained from Standard Current Transformer and in comparison to that the vector length and phase displacement is measured. The ratio error in percentage and phase displacement in minutes are directly compared and indicated on dials.
-
Product
Primary Current Injection Kits
-
During installation,testing,especially if the protective gear is connected to the power line via a current transformer it is advisable to use our Primary Injection Test Set. Keeping this in mind a wide range of Primary Current Injection Test Sets are being manufactured by "NMC”.
-
Product
Standard Current Transformers
-
Measurements International Ltd.
Single Range, Highest Permeability, Wide Measurement Range, Negligible Current Errors, High Accuracy.
-
Product
Instrument Transformer Comparator
PMT20010
-
Power Measurement Technologies Inc.
The PMT20010 Comparator is an automatically balancing bridge that measures the accuracy of instrumentation potential and current transformers.
-
Product
All-at-once Waveform Visualizer and Comparator
Oscilloscope Multi
-
The plugin offers stereo or mid-side channels waveform extraction as well as several synchronization modes. The zooming and precise measurement capabilities let you analyze the waveforms in details, and the XY phase scope view will help you track phase issues within an effect chain or while recording with multiple microphones
-
Product
Current logger0 to 20mA
TK-4802
-
Supplied with an input cable, this logger can measure current between 0 and 20mA DC and can be connected to many industry standard devices, such as CO2 sensors and current clamps, enabling the logging of a wide range of process parameters.
-
Product
Current Data Logger 0-24mA
VA601-A125
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Multi-function record meter is a new record meter designed for the actual demand of various industrial site, which integr.
-
Product
DC BIAS CURRENT UNIT
3265B SERIES
-
To evaluate components at currents up to 125 A the 3265B DC Bias Units are used with either the Wayne Kerr 3255B series of Inductance Analyzers or the 3260B Precision Magnetics Analyzer. When one 3265B/25A or 3265BQ/25A DC Bias Unit is connected to an instrument up to 25 A of DC bias current can be set in steps of 25 mA with one unit. Additional DC Bias Units can be added such that with five units connected in parallel it is possible to set DC bias currents up to a maximum of 125 A DC.
-
Product
Precision Multirange Current Transformer
P-5000
-
The P-5000 transformer is a laboratory standard. The unit’s excellent accuracy and the Knopp One-to-One calibrating feature make this precision transformer well-suited as a standard for calibration work. This transformer can provide a very accurate determination of the ratio and phase angle characteristics of current instrument transformers having ratios from 5 to 5,000 amperes. This transformer also can accurately extend the range of a 5 ampere ammeter or wattmeter to cover all current values up to 5,000 amperes.
-
Product
Multi-Channel, Programmable Current Source
CS-48-100
-
The Model CS-48-100 is a multi-channel, programmable current source. Developed for both semiconductor and digital superconductor electronics, it is computer-controlled and features 48 low noise current source outputs. Each source output has the capability to both set and read back currents and can be set to a zero current high Z mute state. Each of the 48 sources are optically coupled for control and are sourced from their own secondary winding for complete galvanic isolation. The device consumes a maximum of only 80 W and handles a maximum load current of 4.8 A total over all outputs. Operating over a range of 0-100 mA on each channel, the device features accuracy of +/-25 ?A. The mute state can be set thru a rear panel interlock or from the front panel button for maximum circuit protection. The unit can be mounted in a standard-sized rack.