Loop Calibrators
Simulate, power and measure closed circuit signals.
-
Product
Signal Calibrators
-
Nagman Instruments & Electronics Pvt. Ltd
If you are looking for Signal calibrators that are best in industry, head over to Nagman website immediately. We have a range of signal calibrators, loop calibrators, milliamp calibrators, process meter and more. Depending on the requirement at hand, you can find a signal calibrator that is best suited for your industry. Signal calibrators can be used for calibrating thermocouples, RTD, transmitters, etc. while loop calibrators are used for calibrating controllers, indicators, etc. Nagman’s range of signal calibrators are handy, light weight, portable and durable.
-
Product
Loop Calibrator
Model KM CAL-904-MK1
-
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load
-
Product
Pressure Calibrator
HPC40
-
AMETEK Sensors, Test & Calibration
The HPC40 Series handheld pressure calibrator is the world's first combined pressure and mA loop calibrator to be fully temperature compensated from -20 to 50°C. You can count on the same accuracy whether measuring pressure, current, voltage, or temperature.
-
Product
Milliamp Calibrators & Loop Calibrators
-
Practical Instrument Electronics, Inc.
PIE has milliamp calibrators to fit your needs from the PIE 334 with the basic functions of a 4-20 milliamp calibrator to the advanced loop troubleshooting capabilities of the Model 532. And PIE milliamp calibrators are the only models with patented Loop Diagnostic Technology! All the loop calibrators have fuse-less protection, rugged design, long battery life. Calibrate in the units matching your instruments by displaying in milliamps and percent (%) of 4 to 20 milliamps.
-
Product
mA Loop Calibrators
-
AMETEK Sensors, Test & Calibration
Our mA loop calibrator is an economical and easy-to-use calibration device for sourcing and measuring mA signals. Measure and source current to 24 mA and measure voltage to 45 VDC. Combine our 24VDCPS with one of our handheld pressure calibrators to calibrate transmitters in the field.
-
Product
Process Calibrators
-
AMETEK Sensors, Test & Calibration
Our process calibrators include innovative handheld multifunction calibrators, multi-channel scanners, and handheld loop calibrators and power sources. Our multifunction calibrators feature a new large full color display with an advanced simplicity, easy-to-use interface. The multi-scanner is perfect when there is a need to create traceable documents for sensor calibrations. Calibrate 16 types of RTDs, and 13 types of thermocouples with our handheld calibrators.
-
Product
mA Loop Calibrators
-
Loop Calibrators are indispensable tools for process calibration professionals and we have just one you need. Choose from three different models depending on your need for accuracy and intrinsic safety. Each one is feature-rich and simple to operate and read.
-
Product
Calibrator Process
VA70034
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Loop calibrator This Calibrator is use to measure or output 0 to 24 mA DC current loop, and 0 to 20 V DC voltage.
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, 7 Mm
85031B
Mechanical Calibration Kit
The Keysight 85031B calibration kit contains a set of precision 7 mm fixed terminations and a one-piece open/short circuit used to calibrate Keysight network analyzers for measurement of devices with precision 7 mm connectors. This kit is specified from dc to 6 GHz.
-
Product
4-In-1 OSLT Mechanical Calibration Kit, DC To 26.5 GHz, Type-3.5 Mm (m) 50 Ohm
85520A
Mechanical Calibration Kit
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit.
-
Product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
Calibration Cable
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
Product
7-Meter Laser Head Cable
10882B
Calibration Cable
The 10882B 7-meter Laser Head Cable is used to connect the 5519A/B Laser Head to the E1735A USB Axis Module for the 5530 Laser Calibration System.
-
Product
15-meter (49 feet) Sensor Cable
E1739C
Calibration Cable
The E1739C 15-meter (49 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System. Other cable lengths available: E1739A 5-meter (16 feet), E1739B 10-meter (33 feet) and E1739D 25-meter (82 feet).
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
Mechanical Calibration Kit
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
Economy Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036E
Mechanical Calibration Kit
The Keysight 85036E economy calibration kit contains precision 75 ohm type-N male fixed termination and a one-piece 75 ohm type-N open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. The kit is specified from dc to 3 GHz.
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, Type-N, 50 Ohm
85032E
Mechanical Calibration Kit
The Keysight 85032E economy calibration kit contains a type-N male fixed termination and a one-piece type-N male open/short circuit. These standards are used to calibrate Keysight network analyzers for measurement of devices with 50 ohm type-N connectors. The kit is specified from dc to 6 GHz.
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
Mechanical Calibration Kit
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
Product
CalPod Drive Cable Extension, 10 Meter
85554A
Calibration Cable
85554A CalPod Drive Cable (10 meter length) extends the length of CalPod control cables when the distance between the 85523B to the CalPod modules is >2 m.
-
Product
CalPod Drive Cable, 40 GHz, 2 Meter
85553A
Calibration Cable
This cable provides the bias voltages and control signals for operation of the 40 GHz CalPod modules. This cable is supplied with the 85540/41/42A CalPod modules.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz
85515A
Mechanical Calibration Kit
The 85515A 4-in-1 mechanical calibration module combines an open, short, load, and through in a compact unit. The product is small, easy to handle, and light weight. The through allows users to easily calibrate non-insertable devices, such as a cable or filter with female-female connectors. During the “thru” part of the calibration, the 85515A through can be used.
-
Product
10-meter (33 feet) Sensor Cable
E1739B
Calibration Cable
The E1739B 10-meter (33 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.Other cable lengths available: E1739A 5-meter (16 feet), E1739C (49 feet) 15-meter and E1739D 25-meter (82 feet).
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7–16 (male)
85038M
Mechanical Calibration Kit
Modern wireless communication systems require high-performance components offering low VSWR and low intermodulation distortion at high transmit power levels. To meet these needs, 7-16 connectors are becoming increasingly common in base station transmitters, amplifiers, duplexers, and other products. These connectors conform to IEC 169-4, DIN 47223, European standard EN 122190, and British standard BSEN 122190.
-
Product
Linear Measurement Kit
55280B
Mechanical Calibration Kit
The Keysight 55280B Linear Measurement Kit is part of the 5530 Laser Calibration System and enables the system to measure linear displacement and velocity along a machine's travel path. The purpose of this measurement is to document capability and, when possible, improve positioning accuracy along an axis for any machine that requires positioning accuracy and velocity control.
-
Product
Sensor Cable, 5 M
E1739A
Calibration Cable
The E1739A 5-meter (16 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
Product
Linear Measurement Kit
55280A
Mechanical Calibration Kit
The Keysight 55280A Linear Measurement Kit, used with the Keysight 5530 Laser Calibration System, includes the optical equipment needed to measure linear distance (displacement) and velocity. The kit contains a Keysight 10766A Linear Interferometer, two Keysight 10767A Linear Retroreflectors, mounting hardware, andtransit case.
-
Product
Calibration Lead Precision Resistor, Triple
40-975-009-SL3
Calibration Lead Cable Assembly
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
Mechanical Calibration Kit, 18 To 26.5 GHz, Waveguide, WR-42
K11644A
Mechanical Calibration Kit
The Keysight K11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the Thru-Reflect-Line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
Product
1 Mm Calibration Kit
85059B
Mechanical Calibration Kit
The Keysight 85059B is a 1.0 mm calibration kit designed for vector network analyzer systems operating over the frequency range of DC to 120 GHz. The opens, shorts and loads in this kit are optimized to provide accurate and traceable calibrations over the specified frequency range. The 85059B with 85059V 1 mm Verification kit are replacements for the 85059A 1 mm calibration/verification kit.
-
Product
Calibration Lead Precision Resistor - Single
40-975-009-SL1
Calibration Lead Cable Assembly
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
Product
Standard Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036B
Mechanical Calibration Kit
The Keysight 85036B calibration kit contains precision 75 ohm type-N standards used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 3 GHz.