Filter Results By:
Products
Applications
Manufacturers
-
product
Humidity Measurement
Martindale Electric Humidity Measurement - hygro-anemometer, hygro-moisture meter
-
product
600MHz To 6GHz Radiation Measurement System
RMS-0660
The MegiQ Radiation Measurement System (RMS) is a compact test system that performs 3-axis radiation pattern measurement in non-anechoic spaces.
-
product
Measurement Types and Kits
Keysight supplies a wide variety of optics for different calibration measurements. Choose individual optics or a pre-configured kit. Select desired measurement type from the chart or individual optics listed below.
-
product
8 Channels, RTD Measurement
RT1
The module provides 8 measurement channels, and can be programmed for interfacing to 2, 3, and 4-wire platinum RTD sensor configurations. The 4-wire mode (default) is the most accurate, providing excellent stability and repeatability. The RTD channels feature individual A/D converters and precision excitation/current drive. Programmable lead-wire compensation is provided for inherently less accurate 2 and 3-wire configurations. All RTD channels are self-aligning because each channel is automatically "aligned" on a rotating basis to eliminate offset and gain errors throughout the operating envelope. Programmability for expected resistance range and wire modes allows for optimization of scaling/resolution, as well as flexibility in reading many RTD types.
-
product
Test & Measurement Assemblies
Test & Measurement cable assemblies for a variety of applications
-
product
Test and Measurement Products
Whether for commercial applications, military maintenance, or electronic military instrumentation, Bird has a built-in, single-minded devotion to reliability. Bird has become known as the world's most reliable RF specialists for all markets and segments because to you, yours is the only market or segment that matters.
-
product
Air Temperature Sensors
Campbell Scientific offers a variety of sensors for measuring air temperature. The electrical signals transmitted from the sensors to our dataloggers can be converted to different units of measurement, including °C , °F, and °K. Our dataloggers are also capable of measuring most commercially available air temperature sensors.
-
product
DC High-Voltage Test Device
PGK 50
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PGK 50. The portable, one-piece PGK 50 high-voltage test device for generating negative DC voltage up to 50 kV is primarily used for onsite testing of paper-insulated mass-impregnated cables in the medium-voltage network. The high voltage is generated through a high-voltage transformer with secondary voltage-multiplier. The internal operating frequency of 20 kHz enables the smallest of device dimensions.* Continuous adjustable output voltage* The voltage measurement is done directly at the high voltage output* Timer of 1-30 min* Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal
-
product
3 AXIS DIGITAL AC GAUSSMETER
IDR-fw4180
Integrity Design and Reseach Corp.
This FWBELL 4190 model features three axis sensors which insure that measurements remain accurate regardless of the orientation of the instrument.
-
product
Pyranometer products
Hukseflux Thermal Sensors B.V.
Hukseflux is a leading manufacturer, both in technology and market share, of pyranometers, pyrheliometers, pyrgeometers, net radiometers and albedometers.We produce a complete range of solar and longwave radiation sensors, compliant with the latest ISO, IEC and WMO standards. Each Hukseflux pyranometer is classified as ISO 9060 secondary standard, first class, or second class, and offers the best measurement accuracy in its class. Pyranometer output is analogue and/or digital (Modbus over RS-485/TTL).
-
product
6000 Series Analog I/O Modules
Series 6000 analog I/O modules condition, amplify, filter and digitize signals from virtually any transducer. All modules have conditioning & amplifier per channel and nearly all modules allow for setting bridge completion, shunt calibration, transducer power, gain, etc. individually per channel. Following the conditioning/amplifier stage, multi-pole Bessel or Butterworth analog filters are provided on each channel and can be set or bypassed individually by program control. A number of the modules include a high level analog output providing a conditioned/filtered output to a redundant, external A/D system. A 16-Bit Successive Approximation A/D follows the analog filter stage. Some modules use a single A/D with sample and hold while others have an A/D per channel. Sample rates are programmable per channel to easily accommodate mixing high and low speed measurements into a single data stream. Programmable hardware based warnings and alarms are included in the channel-by-channel architecture and are detected by digital output modules in the system, providing an ultra-low latency control capability directly from the data acquisition system.
-
product
Power Analyzers
Current measurement option for PW6001/ 3390/ 3390-10 Wide-band DC to 3.5MHz, 50A AC/DC rated input, 0.04V/A output PW9100-03 : 3 channels PW9100-04 : 4 channels
-
product
Wet/Wet Differential Pressure Transmitter
655
The Series 655 Wet/Wet Differential Pressure Transmitter converts a positive or a positive differential pressure measurement into a standard 4-20 mA output signal. Designed for use as a wet/wet differential pressure transmitter, units can be used to measure gas or liquid pressures compatible with 316/316L stainless steel wetted parts
-
product
Infrared Camera
TI-240
Shenzhen Calibeur Industries Co., Ltd..
Detector Type: Focal Plane Array, Uncooled MicrobolometerPixel Resolution: 160x120Spectral Band: 8~14μmField Of View: 14°x11°/0.5mSpatial Resolution: 5mradThermal Sensitivity(Netd): ≤50mk@30Focusing: Manual Focus (0.3m~∞)Maximum Frame Rate: 15HzLCD: 2.5′ LCDTemperature Ranges: -20℃~+300℃Accuracy: ±2℃ Or ±2%Temperature Measurement Mode: Real Time Temperature Display, User Defined Points Or Areas of InterestRadiance Correction: 0.01-1.0
-
product
Field-installation Type Residual Chlorine Meter (Four-Wire Transmission, Rotating Type)
HR-200RT
HR-200RT is connected to a residual chlorine sensor (RA-30), which allows the free residual chlorine concentration to be measured with high accuracy. It is sutable for waterworks, pool water sterilization, and desalination systems. The measurement method is a three-pole polarographic method, which enables continuous monitoring of residual chlorine concentrations without using reagents.Stable measurement over a long period was realized by physical polishing cleaning using beads.
-
product
MagScope Software
MagScope is Magcam's advanced data analysis software formeasuring and analyzing magnetic field distributions.MagScope is designed to extract as much informationas possible from the measurement data. MagScope is integrated in and optimized for all our magnetic field cameras and scanners.
-
product
Highly Sensitive Silica Monitor
SLIA-300
The ultra-pure water that is used in the semiconductor production processes can be further purified by using an ion-exchange resin. Capturing the silica that is dissolved from this ion-exchange resin as quickly as possible can control the ultra-pure water quality, which is important during the production processes.HORIBA Advanced Techno has developed and employed a new "long light path length measurement cell" to enable highly sensitive measurement of ultra-low density silica and also realized a compact desktop model to improve the usability.
-
product
Miniature Concentric Ring Set
PRF-912B
- Measures Surface Resistance from 0.9Ω to 1.0x1012Ω- Approximates Measurements Typically Obtained when using ANSI/ESD STM11.11- Spacing Allows for Measurement Area of 0.32 inches (8.13mm)- Spring Loaded Center Electrode Surrounded by 10 Contact Electrodes- Includes Conductive Rubber Covers- Certificate of Calibration Traceable to NIST included
-
product
Asphalt Testing Equipment
ELE international manufactures a comprehensive range of field and laboratory asphalt testing equipment to ensure compliance with quality and performance specifications. Traditional methods of binder content analysis involved the use of solvents, but due to environmental concerns ELE has developed an Asphalt Binder Analyser which uses an ignition method and thereby avoids the use of harmful solvents. Loss on heating and a rolling thin-film oven are used for testing bitumen, flash and fire point are measured with the Cleveland Flash Cup Apparatus, and the Ring and Ball test enables the measurement of the softening point.
-
product
Power Detectors
Get accurate measurements with fast response times with our thermopile or pyroelectric power meters. Available with various absorbers, with the highest damage thresholds you can find in their category, our power meters cover a wide range going from the nanowatts to multi-kilowatts.
-
product
PCI-5922, 24-Bit, Flexible Resolution PCI Oscilloscope Device
779659-03
24-Bit, Flexible Resolution PCI Oscilloscope Device - The PCI‑5922 high resolution oscilloscope device features a flexible measurement resolution range up to 24 bits and up to 15 MS/s rates. This oscilloscope device has flexible settings for coupling, and voltage range, as well as a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. The PCI‑5922 is capable of taking extremely resolute and accurate analog measurements. It is ideal for audio signals, spectrum analysis, and any other small, accurate signal measurements.
-
product
Magnetic Field Meter
Measurement for the magnetic field generated from Direct Current (DC, with display by N/S Magnetic polarity) or Alternating Current (AC in 40-500Hz).
-
product
Differential Picosecond Pulse Generators
PicoSource PG900 Series
The fast-transition pulse can stimulate a transmission path, device or network with a broad spectrum signal in a single instant. Such a pulse is very useful for many of the high-speed broadband measurements that we need to make; for instance in time-domain reflectometry, semiconductor test, gigabit interconnect and port test and in radar.
-
product
Calibration Standards
The accuracy of any spectroradiometric measurement can only be as good as that of the standard source used to calibrate the system.
-
product
180V-260V AC Socket Tester (For UK)
1941
Peaceful Thriving Enterprise Co Ltd
*With UKCA Approval.*LED indicators & Digital display.*Test for 180-260VAC circuit.I*t can perform self test after plug-in ( Voltage sould be above 180V ).*Detect faulty wiring status in 3 wire receptacle.*This socket tester will give LED indication as well if the main voltage is below 200V or above 260V.*Earth loop impedance test.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 4W*Frequency: 50Hz
-
product
Multifunction Installation Tester
COMBI519
COMBI519 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
product
Measurement Systems
MicroMeasure3D
Sciences et Techniques Industrielles de la Lumière
STIL MicroMeasure3D, PORTICO3D and MAESTRO3D are measurement systems designed to achieve true 3D metrology of each point for the most demanding applications adapted to Industry 4.0 standards.
-
product
PH And Temperature Pen
Ultrapen™ PT2
This instrument is designed to be extremely accurate, fast and simple to use in diverse water quality applications. Advanced features include automatic temperature compensation; highly stable microprocessor-based circuitry; user-intuitive design; and waterproof housing. A true one-handed instrument, the PT2 is easy to calibrate and easy to use. To take a measurement, you simply push a button then dip the pen in solution. Results display in seconds.
-
product
Programmable AC Power Source
LSP-500VAC
• Applied with the AC-DC-AC inverter technology and digital waveform synthesis & waveform feedback technology, low distortion power; • Applied with entire cycle high-precision measurement technology and high-speed sampling technologies, panel of instrument will directly and accurately displays the power output of the voltage, frequency, current, active power and power factor to achieve the integration of the source table; • Applied with SCM control and measurement technology, high intelligence; • Applied with zero output impedance technology, the output equivalent impedance is almost zero and further improve the stability of power supply; • Applied with isolated floating output technology, the power output and input have good isolation, floating output, conducive to make sure power itself safety and operator’s safety; • Perfect voltage, current anomalies and overheating protection, improve the reliability of power supply; • Applied with power limiting technology to avoid strong interference on the power grid and other electrical equipment, while facilitating reliable operation of the power supply itself; • The input voltage can be option via a toggle switch of panel mains 110V/220V; • The initial phase and end phase of the output voltage waveform can be set {0°-359° (±1°)}; • Measurement process can be programmed to control (1 to 50 memory groups, 1 to 9 steps for each memory group);
-
product
NI-9264, 25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module
780927-01
25 kS/s/ch Simultaneous, ±10 V, 16-Channel C Series Voltage Output Module - The NI‑9264 is a simultaneously updating analog output module that accommodates higher‑channel‑count systems. Higher density modules conserve chassis space, which leaves room for other measurement types. Each channel has its own digital‑to‑analog converter. The spring-terminal version of the NI‑9264 uses a 36‑position connector for the output channels, and each channel has a ground connection.