Filter Results By:
Products
Applications
Manufacturers
Oscilloscope Probes
probe with lead for single-ended measurements connected to ground.
See Also: Oscilloscopes, Analog Oscilloscopes, Digital Storage Oscilloscopes
-
product
AC / DC Current Probe, 100 KHz, 100 A
1146B
The Keysight 1146B AC / DC probe provides accurate display and measurement of currents up to 100 A DC or peak AC / DC to 100 kHz without breaking the circuit. The 1146B AC / DC probe has hall-effect sensor technology to measure AC and DC signals. It is compatible with any Keysight oscilloscope with 0.2 to 0.5 V / div sensitivity and 1 MΩ BNC input.
-
product
Near Field Probes 30 MHz up to 6 GHz
XF1 set
The XF1 set of near field probes consists of 4 passive near field probes and one passive E field probe for making measurements in the development phase of the magnetic and electric fields in ranges from 30 MHz to 6 GHz. Due to their integrated impendance matching, the probes are less sensitive in the lower frequency range than the RF type probes. The probe heads of the XF1 set allow for the step by step identification of interference sources of the magnetic field on an electronic assembly. At first, for example the XF-R 400-1 detects the fields which the assembly emits in total. Next, using higher resolution probes the interference sources can be more precisely detected. The E field probe is used for the detection of electric interfering fields near the assemblies. With trained use of the near field probes, field orientation and field distribution can be detected. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.
-
product
SA1500X, 1.5 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784256-01
The SA1500X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
product
SA2500X, 2.5 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784257-01
The SA2500X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
product
High Impedance Active Probes
12C
A high speed, high input impedance active probe for measuring the internal node voltage of integrated circuits. The input is 1 megohm shunted by 0.1 pf and the rise/fall times are 0.8 ns. This instrument has full dc capability and can be used with any oscilloscope. The Model 12C was specially designed so that when used in conjunction with a high input impedance oscilloscope, signal attenuation is 10:1 and with a 50 Ohm input, signal attenuation is 20:1.
-
product
High-Voltage Differential Probe, 200 MHz
N2805A
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.
-
product
Passive Probe, 10:1, 200 MHz, 2-Pack
N2140A
The Keysight N2140A is an extremely low-cost passive probe that provides a switchable 10:1 / 1:1 attenuation and up to 200 MHz bandwidth. It features a high input resistance of 10 MΩ (switchable to 1 MΩ) to address a wide range of measurement needs with low probe loading. The probe can be adjusted for both low-frequency compensation and high-frequency compensation. For the best measurements, you should compensate your probe to match its characteristics to the oscilloscope. This probe is compatible with Keysight InfiniiVision Series oscilloscopes with 1 MΩ input.
-
product
Inbuilt External Controller ATE with Touch Screen Features
QT 200NXT
Qmax Test Technologies Pvt. Ltd.
QT 200 nxT is a ultra modern stylish Inbuilt external controller ATE with touch screen features, is now available as a desktop unit with the cost, flexibility, and performance demanded by a large number of users in research, design, manufacturing, and repair & maintenance industry. It is a combinational-mixed signal board tester for PCBAs designed to cater the needs of PCB test and repair depots, keeping in mind the changing PCB technology and challenges in testing them offline with the combination of all such complex test methodologies in a single test hardware platform with simple to use graphical user interface software. The vast library support helps you to functionally test host of different IC families. Other features like user-friendly Windows based software, add-on utilities like oscilloscope, RCV meter circuit tracer, etc. makes it a favorite and makes very effective for repairing PCBs without schematic/ circuit diagrams. All these tests are carried out using simple BUT Interface like multipin test clips, probes or custom test fixture
-
product
CC05120X, 120 MHz, 5 Arms Current Oscilloscope Probe
786847-01
The CC05120X, or Hioki CT6701, is a clamp-on current probe that offers a wide DC to 120 MHz bandwidth and 5 Arms of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
product
500 MHz, 1.0 pF Active Differential Probe
ZD500
With the ProBus interface, the ZD500, 1000, and 1500 becomes an integral part of the oscilloscope. All probe gain and offset controls are transparent to the user, making it easier to probe the circuit without concern for which gain setting to choose. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
product
T3DSO Passive Probe, 350 MHz, 1X/10X, 1 MOhm/10 MOhm, 300V/600V
T3PP350
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
Differential Voltage Probes
DP150/DP200pro
The DP differential isolation probes are an important accessory for any laboratory involved in power electronics and high voltage systems. These probes allow isolated and floating measurements with any oscilloscope or data recorder, whilst the oscilloscope can remain grounded. Using a DP150 or DP200pro probe, differential and floating measurements can be made on a variety of ac power systems like 230V/110V ac input power supplies, chopped and switching power supplies, thyristor controllers, variable speed motor drives (PWM signals), motor inrush current and measurement across current shunts. The isolated input is made via two 4mm/banana safety sockets. The BNC output allows easy connection to an oscilloscope. The DP probes can be powered from a 9V battery or external power supply.
-
product
Passive Probe, 10:1, 75 MHz, 2-Pack
N2142A
The Keysight N2142A is an extremely low-cost passive probe that provides a switchable 10:1 / 1:1 attenuation and up to 75 MHz bandwidth. It features a high input resistance of 10 MΩ (switchable to 1 MΩ) to address a wide range of measurement needs with low probe loading. The probe can be adjusted for both low-frequency compensation and high-frequency compensation. For the best measurements, you should compensate your probe to match its characteristics to the oscilloscope. This probe is compatible with Keysight InfiniiVision Series oscilloscopes with 1 MΩ input.
-
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP023-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
400 MHz High Voltage Passive Probe
HVP120
High voltage single-ended passive probes are suitable for a wide range of applications where ground-referenced high-voltage measurements must be made safely and accurately. There is also a sense pin to automatically configure the oscilloscope for use with the probe.
-
product
MOD MONITOR
TYPE HFX-1
The Type HFX-1 Modulation Monitor is an ancillary piece of equipment, which is used with narrow bandwidth, or older oscilloscopes to allow viewing of RF signals and particularly modulated signals as high as 55MHz. The equipment contains an RF signal source and a broadband mixing circuit which converts the high frequency signal to an intermediate frequency within the oscilloscope’s range. The frequency control dial is simply adjusted until the RF signal is viewed on the scope. BNC connectors are mounted on the rear panel to allow interconnect to the scope and RF probe. This product was previously called "oscilloscope frequency extender" and may be used to view other high frequency signals on older or narrow band scopes.
-
product
High Impedance Active Probes
34A
Engineered to meet the stringent demands of advanced high frequency circuit designers. This high impedance probe combines full DC capability, rise/fall times of 120 ps, and a nominal loading input impedance of 10 megohm shunted by 0.1 pf. Signal attenuation is 20:1 with a 50 ohm oscilloscope input.
-
product
Low Voltage Differential Oscilloscope Probes
Differential signaling used in high speed serial standards requires very accurate characterization. The industry-leading bandwidth and signal fidelity found in a Tektronix low voltage differential oscilloscope probe ensures that you see every possible detail. Tektronix offers TriMode™ architecture which streamlines measurement acquisition by enabling you to make differential, single-ended, and common mode measurements with a single connection!
-
product
High Voltage Differential Probes
DP Series
Shenzhen Micsig Instruments Co., Ltd.
*Micsig DP Series High Voltage Differential Probes can be used with any brand of oscilloscope. *It adopts high-impedance isolation between the input and output to protect personal safety, converts the input high-voltage signal to a low-voltage signal for observation and analysis on oscilloscope.
-
product
DMM Terminal Test Lead
U1580A
The Keysight U1580A test leads are compatible with the U1600A Series handheld digital oscilloscope probes and test leads. These test leads are used for the DMM terminal on the oscilloscopes.
-
product
High-Voltage Differential Probe, 100 MHz
N2790A
Use the N2790A 100-MHz high-voltage differential probe to make safe and accurate floating measurements with an oscilloscope. The N2790A probe allows conventional earth-grounded Keysight oscilloscopes to be used for floating signal measurements of up to 1,400 V of differential voltage and 1,000 V of common mode voltage.
-
product
Power Integrity Analyzer Reference Solution
The power integrity analyzer reference solution is a hardware-based solution with the Keysight Infiniium S-Series 10-Bit ADC oscilloscope and probes, including the N7020A power rail probe that lets you see the true AC power noise on your DC power line and supports up to +/- 24 V offset and the N2820A high-sensitivity current probe that can measure down to 50 uA.
-
product
T3DSO2000HD Series Oscilloscopes
T3DSO2000HD Series
The Teledyne Test Tools T3DSO2000HD Oscilloscopes feature four channel bench models with analog bandwidth options of 100 MHz, 200 MHz and 350 MHz all with 12 bits of vertical resolution. The series offers both DSO and MSO configured models with the MSO units having a 16 channel logic probe as standard. Each model offers a maximum sample rate of up to 2 GSa/s sample rate (interleave mode), and a maximum memory depth of 200 Mpts in interleave mode.
-
product
Sensor Unit for High Precision Current Sensors
CT9557
Hioki pull-through current sensors and clamp on current probes are best-in-class current sensing devices for use with power meters, Memory HiCorders and high performance oscilloscopes. The CT9555 is 4-channel sensor unit and power adapter for any of the CT686x series, 9709 and CT684x series current sensors and probes that provides waveform and RMS output.
-
product
HandyScope HS6-DIFF With SureConnect: 500 MS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-500XMS-W5
The only oscilloscope in the world that has:- SafeGround, differential input channels that can be switched to single ended.SureConnect, auto-detects a true connection between the probe tip and the device under test.- CMI interface.- USB 3.0 interface, 5Gb/s data transfer- Lowest noise
-
product
Oscilloscope Current Probe,DC~200KHz(-3db),400A
CP-05B
Amorphous Alloy CoreRange:40A,5us,400A,5usBandwidth:DC~200KHz(-3db)Rise time:1.75μsLow battery indicationNoise level: 100mA Jaw size: 23mm(Max)Auto Zero at power onRelative Zero correctionSize 180mm(L) X 44mm(w) X 30mm(H)Weight: Approx 200g
-
product
Oscilloscopes And Probes
An oscilloscope is quite possibly the most used piece of test equipment on an engineer’s bench. They are used by electrical engineers or anyone else wishing to measure electrical characteristics of electronic devices. However, you need more than just an oscilloscope to complete your job - you also need one or more oscilloscope probes to make accurate measurements.
-
product
1 GHz, 1.0 pF Active Differential probe
ZD1000
With the ProBus interface, the ZD500, 1000, and 1500 becomes an integral part of the oscilloscope. All probe gain and offset controls are transparent to the user, making it easier to probe the circuit without concern for which gain setting to choose. When used with a LeCroy digital oscilloscope, no external power supply is required.
-
product
DDR4 MSO Probes
The DDR4 DIIM and SO-DIMM Mixed Signal Interposers connect Address, Command and Control signals of a DDR4 bus to the Keysight V-Series Oscilloscopes with the MSO option. These interposers also provide accessibility to DDR4 signals for convenient analog probing. The user can then easily observe both the digital and analog representation of the DDR4 Address, Command and Control bus. Solder down N5541A analog probes purchased separately from Keysight Technologies.
-
product
Scanner Probe
RFS set
The RFS set consits of three passive near field probes designed for the use in a measurement scanner during the development of E-field and magnetic field. They are designed for frequency ranges of 30 MHz to 3 GHz. The probe heads of the RFS set allow for close measurements needed to correctly localize interference sources on an electronic assembly. They document the whole image of the device under test`s near field. The scanner probes have a sheath current attenuation and are electrically shielded. They are connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance. The measuring signal can be increased with PA 203 or PA 303 preamplifier. On request RFS, LFS and XFS scanner probes can be produced.