Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
PXIe Vector Signal Analyzer: 6 GHz
M9391A
Vector Signal Generator
RF requirements keep growing while timelines keep shrinking. To help ease the technical and business pressures, the right test solution provides continuity in measurements and longevity in capability. In the evolution of modular RF test solutions, the Keysight PXI VSA is the next logical step in signal analysis. With raw hardware speed and X-Series measurement applications, it delivers proven results faster. From fully modular hardware to software leverage to worldwide support, the PXI VSA is the low-risk way to manage change and be ready for tomorrow today
-
Product
Signal, Contact, ITA, TriPaddle, 7 Amp, 26-28 AWG
610110169
Signal Contact (ITA)
Primary mating contact 610110167. (May mate with other Receiver contacts, as well.)
-
Product
Vector Network Analyzer (VNA) Simulator – Standard
S94050B
Vector Network Analyzer
S94050B puts flexible S-parameter analysis into your own computer. Dive deeper into measurements captured on a network analyzer or develop and optimize test programs before deploying them onto an instrument.
-
Product
PCIe 16 Bit Arbitrary Waveform Generator - up to 125 MS/s on 1 Channel, High Voltage Outputs
M2P.6570-X4
Arbitrary Waveform Generator
The M2p.65xx series offers different versions of arbitrary waveform generators for PCI Express with a maximum output rate of 125 MS/s. These boards allow to generate freely definable waveforms on several channels synchronously. With one of the synchronization options the setup of synchronous multi channel systems is possible as well as the combination of arbitrary waveform generator with digitizers of the M2p product family. The 512 MSample on-board memory can be used as arbitrary waveform storage or as a FIFO buffer continuously stream data via the PCIe interface. Importantly, the high-resolution 16-bit DACs deliver four times the resolution than AWGs using older 14-bit technology.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74E
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2C40
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35 Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Flat, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0F
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
12GHz 16-Channel Signal Generator 19" 3U Rack Module
LS12916R
Signal Generator
The LS12916R, 12GHz 16 channel RF Analog Signal Generator, offers industry leading performance, in a 3U, 19” space efficient, rack-mounted box. The LS12916R features 16 phase coherent channels, exceptionally fast switching speed, superior signal integrity and purity and all the necessary modulated signals for analog communication systems. With the highest channel density in the market the LS12916R offer the ideal solution for applications requiring high channel count at minimum space and cost.
-
Product
Ultra High 6.70 (190.00) - 11.80 (335.00) General Purpose Probe
EPA-4B-2
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Standard 1.50 (42.00) - 3.30 (94.00) General Purpose Probe
P2663G-1R1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
Product
Alternate 2.82 (80.00) - 5.00 (141.00) General Purpose Probe
HPA-74B-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Comb Generator, 10 MHz to 26.5 GHz
U9391C
Comb Generator
The Keysight Technologies, Inc. U9391C comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
Product
SSA Signal Source Analyzer, 10 MHz to 7 GHz, 26.5 GHz, or 110 GHz
E5052B
Signal Analyzer
RF Input frequency range: 10 MHz to 110 GHz Analysis offset frequency range: 1 Hz to 100 MHz Phase noise measurement with ultra low noise floor and a cross-correlation method Frequency transient capture range: up to 80 MHz in narrow band, up to 4.8 GHz in wide band
-
Product
Ultra High 4.18 (119.00) 11.70 (332.00) General Purpose Probe
EPA-3D-2
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
General Purpose Switches
SMX-5XXX (General Purpose)
General Purpose Switch
The VTI SMX-5xxx Series of general purpose switches deliver exceptional performance and reliability by implementing extensive signal path shielding, isolation and built-in health monitoring. Embedded virtual schematic control simplifies setup and debugging, allowing all relays to be engaged independent of application software and device drivers.Ideally suited for a wide range of discrete signal switching, the SMX-5xxx Series provides uncompromised measurement integrity ideal for the most demanding aerospace, defense and automotive automated test equipment (ATE) applications.
-
Product
Ultra High 4.18 (119.00) 11.70 (332.00) General Purpose Probe
EPA-3G-2
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Streamline USB Vector Network Analyzer, 53 GHz
P5028A
Vector Network Analyzer
Compact, faceless, USB vector network analyzer (VNA). Flexible four-port VNA which dramatically reduces your size of test. Up to 53 GHz.
-
Product
Alternate 2.82 (80.00) - 5.00 (141.00) General Purpose Probe
HPA-74T65-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
PXIe 16 Bit Arbitrary Waveform Generator - up to 625 MS/s on 1 Channel
M4X.6620-X4
Arbitrary Waveform Generator
The M4x.66xx-x4 series arbitrary waveform generators (AWG) deliver the highest performance in both speed and resolution. The series includes PXI Express (PXIe) cards with either one, two or four synchronous channels. The large onboard memory can be segmented to replay different waveform sequences. The AWG features a PCI Express x4 Gen 2 interface that offers outstanding data streaming performance. The interface and Spectrum’s optimized drivers enable data transfer rates in excess of 2.8 GB/s so that signals can continuously replayed at a high output rate. While the cards have been designed using the latest technology they are still software compatible with the drivers from earlier Spectrum waveform generators. So, existing customers can use the same software they developed for a 10 year old 20 MS/s AWG card and for an M4x series 625 MS/s AWG.
-
Product
PXI Vector Network Analyzer, 9 kHz to 9 GHz
M9802A
Vector Network Analyzer
Full 2/4/6/ port VNA on a PXI module with flexible applications.
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-2W1S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
P2250 General Purpose Probes
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,453Overall Length (mm): 36.91Rec. Mounting Hole Size (mil): 126Rec. Mounting Hole Size (mm): 3.20Recommended Drill Size: #30 or 3.20 mm
-
Product
HD Arbitrary Waveform Generator,8 Ch,250 MHz,16 bit,128Mpts/Ch,6 Vpp output,AFG/AWG, Wave Sequencing
T3AWG3258
Arbitrary Waveform Generator
HD Arbitrary Waveform Generator,8 Ch,250 MHz,16 bit,128Mpts/Ch,6 Vpp output,AFG/AWG, Wave Sequencing.
-
Product
Alternate 2.82 (80.00) - 5.00 (141.00) General Purpose Probe
HPA-74C-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
PXIe-5633, 26.5 GHz PXI Vector Network Analyzer
788182-12
Vector Network Analyzer
The PXIe-5633 is a single-slot PXIe Vector Network Analyzer (VNA) that helps you streamline your production test applications. This VNA supports automatic and manual precision calibration, full vector analysis, de-embedding, and pulsed S-parameter capabilities, making it ideal for validation and production operations without the high costs and large footprints associated with traditional benchtop VNAs. The PXIe-5633 also integrates into NI RFmx and Instrument Studio software to provide automated control for test program development. Additionally, the PXIe-5633 features a hardware pass-through path that you can use for PXI Vector Signal Transceivers (VSTs) testing directly at the VNA ports. With combined modulated and S-parameter measurements on a single connection, you can cover both VST and VNA tests on a single device.
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Non Replaceable General Purpose Probe
MEP-20U
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
Product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1C1S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Replaceable General Purpose Probe
MEP-30B
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 30Test Center (mm): 0.76Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 690Overall Length (mm): 17.53
-
Product
PXIe-5745, 12-Bit, 6.4 GS/s, 2-Channel PXI FlexRIO Signal Generator
785598-02
FlexRIO Signal Generator
The PXIe-5745 enables direct RF generation up to 3 GHz with 12 bits of resolution. You can use it in a dual-channel mode at 3.2 GS/s for generation up to 1.5 GHz or in a single-channel wideband upconversion mode at 6.4 GS/s. The PXIe-5745 is ideal for applications that require high channel density IF signal generation with multichannel synchronization, including radar, electronic warfare, and communications. The FlexRIO driver includes support for generating predefined waveforms, and you can use the LabVIEW-programmable Xilinx Kintex UltraScale FPGA for dynamically creating waveforms, signal modulation/demodulation, and other custom real-time signal processing.