Filter Results By:
Products
Applications
Manufacturers
Ground Resistance
Evaluation of the conductance of earth grounding.
See Also: Ground Resistance Clamps, Ground Resistance Testers, Surface Resistivity
-
product
Earth Ground Tester
Weshine Electric Manufacturing Co., Ltd
UT520 series can perform precise 3-wire and simple 2-wire earth resistance measurement for power and electrical systems, lightning protection equipment, and ground system of all electrical equipment.
-
product
2 in 1 LAN Tester
PLTM20
Tests Pin Configuration for 10 Base-T, 10 Base-2, RJ45/RJ11, 356A, TIA-569A/568B and Token Ring CableRemotely Test Cables Up to 330 Yards AwayTest Ground WireMeasure DC/AC Voltage, DC/AC Current, Resistance, Continuity, and DiodeDC Voltage: Max Range 600 V, Accuracy +/- 0.5%AC Voltage: Max Range 600 V, Accuracy +/- 1.2%DC Current: Max Range 200 mA, Accuracy +/- 1.2%AC Current: Max Range 200 mA, Accuracy +/- 2.0%Resistance: Max Range 20 M, Accuracy +/- 0.8%Continuity Test: Beeps If Less Than 100 Accessories Included: Test Leads, LANtest Remote Terminator, 9V Battery, Carrying CaseDimensions: 6.38' H x 2.93' W x 1.73' DWeight: 10.86 oz.Sold as : Unit
-
product
Earth Resistance Meter
EM 4058
earth tester is a digital, microprocessor controlled instrument that allows to measure the earth resistance and ground resistivity (using Wenner´s method), as well as to detect parasitic voltages present in the ground. This instrument is suitable to measure earth systems in power substations, industries, distribution networks, etc., according to IEC 61557-5.
-
product
Guardian Ground Bond Tester
19572
Chroma Systems Solutions, Inc.
Wide resistance measurement range : 0.1 ~ 510 mΩHigh performance AC current output : 45 ACompact size ground bond testerProvide reliable and stable test resultsBuilt-in resistance compensation functionStandard RS-232 interfaceOptional GPIB InterfaceCompatible with the model 19070 series Hipot Tester2-Year factory warranty
-
product
Solid State Relays for Switching Heavy Loads in 6-Pin Mini-DIP Package
Series C63
Series C63 solid-state relays use an advanced design capable of switching heavy loads in a physically small 6-pin mini-DIP package. These relays have a power FET output that ensures low ON resistance and low leakage current. Optical isolation ensures complete protection of signal lines, power and ground bus and control circuits from switching noise and EMI.MSL 6Available options include:C63-10 1A, 60Vdc Load; 8-20mAdc Control; through-hole mountedSC63-10 1A, 60Vdc Load; 8-20mAdc Control; surface mounted
-
product
Digital Earth Resistance Tester
MODEL - KM 2030
Kusam Electrical Industries Limited
• Display : 3½ Digit LCD display.• Ground resistance measurements from 0 ~ 01Ω to 2000Ω with 0.01Ω resolution.• Earth Resistance : 20Ω / 200Ω / 2000Ω• Accuracy : 20Ω : ± (2% + 0.1Ω); 200Ω / 2000Ω : ± (2% + 3)• Earth Voltage : 0 ~ 30V• Accuracy : ± (3% + 5)• Resolution : 0.01Ω• Working LED Indicator.• Data Hold Function.
-
product
Megohm Meter
Digital Megohm Meter, model SMG5, is a compact standalone meter designed for checking HVAC compressor insulation. The SMG5 provides a 1000V voltage source, monitors current, and displays the resistance between the test points. Maximum current output is <1mA. It can be used to determine the condition of insulation from winding to ground in a motor, compressor, or transformer. Includes a case, alligator clip lead tip and leads with removable tips.
-
product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-02
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
Resistance Grounded Systems (HRG/LRG)
Neutral Grounding Resistors (NGRs) are used to limit the maximum ground-fault current. Restriction of fault current lowers hazards and reduces damage done to equipment. High Resistance Grounding (HRG) systems are often used on industrial and critical power applications to maintain system uptime during a first ground fault. HRG systems are also used in tripping applications to help control touch potential on portable loads and improve personnel safety.
-
product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
785189-01
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
Wrist Strap Monitors
Single conductor (more commonly called single wire) ESD wrist strap monitors detect capacitance. These simplified monitors sense the input connection but do not discern precision resistance. They also offer additional value by monitoring the worksurface (ESD Mat) and the ground connection. The built-in LED offers local visual alerts, and a small piezo buzzer offers a nice clear audible alert to the operator at the bench.
-
product
Drop Test Machine
Single-wing Drop Test Machine Simulate the drop conditions of packaged products when different faces, edges and corners fall to the ground from different heights, thus to understand the damage of the product and evaluate the drop height and impact resistance that the packaging materials can endure while falling down, so as to improve and optimize package design according to actual conditions of the product and national standard range.
-
product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-02
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
Installation Testers
Offers two models that verify the safety of electrical installations in residential, commercial and industrial applications. Has been developed to carry out the following safety measurements of electrical installations in accordance with EN 61557 and DIN VDE 0100: Insulation resistance, RCD tests, Low Ohm resistance, Earth ground resistance, Loop impedance, Phase sequence.
-
product
Ground Resistance Testers
Whether you are doing a simplified 2-Point, a more complete 3- or 4-Point Fall-of-Potential test, a soil resistivity test or a touch potential test, AEMC has the right instrument for you. Our revolutionary clamp-on ground resistance tester will save you both time and money. Whichever AEMC ground tester you choose, you can count on it to be the highest quality, the most complete package and the simplest to learn to use.
-
product
Portable Ground Strap Tester
This Ground Strap Tester provides an inexpensive method for guaranteeing the integrity of wrist straps. This compact, automatic test unit checks the specified resistance limits of all types of wrist straps and other similar personnel grounding devices. Incorporates upper and lower resistance tests.
-
product
Electrical Safety Multi-Analyzer
TOS9300 Series
The TOS9300 series is a high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.
-
product
Ground Resistance Clamp Meter
61-920
*Auto ranging*Auto power off*Hard case included*2-year warranty
-
product
AC Ground Bond Tester
448
Our 448 model is a 4-in-1 tester with 500VA AC Hipot, DC Hipot, Insulation Resistance and Ground Bond testing capabilities. The 448 is capable of a 500VA AC Hipot output to comply with 100mA leakage current test compliance requirements. This tester features a simple design and easy-to-use interface, reducing setup time and increasing production-line throughput for your application.
-
product
Earth Ground Testers
Fluke''s family of earth ground testers have been built to address the entire spectrum of ground testing methods from the basic to the most advanced. Our testers have been designed to be accurate, safe and easy to use. We provide quick and precise resistance measurements through several test methods: 3- and 4-pole Fall-of-Potential testing, selective testing, stakeless testing and 2-pole testing. Detailed application information can be found at the Earth Ground Solution Center.
-
product
Ground Resistance Testers
IP67 protected top in the industry Test all ground types from Class A to Class D with a single meter Wide 0 to 2000 measurement range Minimize cabling time with innovative earthing rods and cable winder
-
product
Insulation Resistance Tester
HT2671A / 756
Wuhan Huatian Electric Power Automation Co., Ltd.
Mainly used to check the electrical equipment or electrical line insulation resistance to the ground and phase to ensure the normal operation of these equipment.
-
product
Surface Resistance Meter
WL MIDGET
WL MIDGET Surface Resistance Meter is an ultra-wide range, battery operated, portable instrument for measuring Surface Resistivity and Resistance to Ground of virtually any flat surface conforming to ASTM D-257 standard method by using recommended parallel bar sensing probe. Gives simple, repeatable measurements of conductive, static dissipative, and insulative surfaces. Ranging is automatic due to the use of high-speed OP-AMP Integrated circuits being linear, with changeover points +1/2 decade on a logarithmic scale. Repeatability equals + 5%.
-
product
Multiplexer
SC6540
Our patented SC6540 modular scanning matrix pioneered the largest productivity improvement in the electrical safety compliance industry in years. With up to 16 independent high voltage or high current channels in a convenient 2U design, the SC6540 can be customized in 10 different configurations for multi-point Hipot, Ground Bond, Insulation Resistance and Leakage Current testing.
-
product
Easy Pole Clamp-On Ground Resistance Tester w/ Super Slim Jaw
FT6380
The FT6380 measures grounding resistance simply by clamping to multiple-grounded ground wires. No auxiliary grounding rod is needed, and there is no need to disconnect the ground wire from the grounding rod. The compact, low-profile sensor can be used to clamp ground wires with ease, and also provide AC current measurement functionality and can measure currents ranging from leakage current on the order of several mA to load currents of up to 60 A.
-
product
Cable & Insulation Testers
A cable insulation resistance test is a test that is performed by applying 500 V or more between the conductor and ground and measuring the resulting leakage current. An insulation resistance tester is a test instrument that measures current that leaks through the insulation into ground. Insulation resistance tests can be performed with insulation multi- meters (IMMs) or megohmmeters. Insulation resistance testers are calibrated to display megohms (MΩ) of resistance. A satisfactory insulation resistance measurement should be in millions of ohms.
-
product
Resistivity Meters
Precisely Measure Surface Resistivity, Volume Resistivity, or Resistance to Ground. Advanced Energy's Trek and Monroe resistivity meters offer accurate and repeatable measurements for surface resistivity, volume resistivity, or resistance to the ground.
-
product
Time, Current, And Resistance Meter
AllWin Instrument Science and Technology Co., Ltd.
1. Time, current and resistance can be displayed simultaneously2. Out put current:5~30A. Ground resistance range: 50~600 mohm
-
product
NI-9217, 4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
779592-01
4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9217 is a resistance temperature detector (RTD) input module. You can configure the NI‑9217 for two sample rate modes: high sample rate or high resolution. The NI‑9217 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9217 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.