Fiber Optic Multiplexers
Process multiple optical signals into one single optical signal.
-
Product
PXI/PXIe MEMS Optical MUX, Single 2-Channel, Multi-Mode, 62.5/125 Fiber
40-855A-212-M-HI
Multiplexer Module
The 40/42-855A-212-M-HI is a PXI/PXIe 2-channel multiplexer with SC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
LXI Microwave Multiplexer, SP6T, 4-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-800-504
Microwave Multiplexer
Our 60-800-504 is a 4 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 40GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI/PXIe High Density 2A Multiplexer, 2-Bank, 32-Channel, 2-Pole
40-614D-011
Multiplexer Module
The 40-614D-011 (PXI) and 42-614D-011 (PXIe) 2-bank, 32-channel, 2-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI Single SP6T Multiplexer 50GHz 50, SMA-2.4
40-785B-551
Multiplexer Module
The 40-785B-551 is a single 6-channel 50GHz unterminated microwave multiplexer. The 40-785B range of multiplexers are available as a single or dual 6-channel panel mounted multiplexer with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
PXI 2A Multiplexer, 8-Bank, 8-Channel, 2-Pole
40-614B-004
Multiplexer Module
This 8-bank, 8-channel, 2-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
LXI Microwave Multiplexer, SP6T, 11-Bank, 67GHz, 50Ω, SMA-1.85
60-800-811
Microwave Multiplexer
Our 60-800-811 is a 11 bank SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 67GHz. The 60-800 range is capable of supporting up to 16 banks of 6 channel multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
16-Channel Multiplexer (2 / 4-Wire) Module for DAQ970A and DAQ973A
DAQM902A
Multiplexer Module
DAQM902A 16 Channel Multiplexer (2/4-wire) Module. Reed relays with high voltage switching of up to 300 V and scan speed up to 250 ch/s.
-
Product
Dual 24-Channel 1-Pole 5 Amp PXI Solid State Multiplexer
40-652-002
Multiplexer Module
The 40-652 range of multiplexers uses solid state relays with high tolerance to surge currents and hot switching events. Each multiplexer provides an isolation relay in the common to minimize capacitive loading when expanding the multiplexer across multiple modules. The 40-652 can sustain 30A for 300s on hot or cold switching. User connections are made via a 50-way D-Type connector which is fully support by our comprehensive range of cables and connector accessories.
-
Product
PXI/PXIe MEMS Optical Switch, Quad Insert/Bypass
40-860A-442
Multiplexer Module
The 40/42-860A-442 is a PXI/PXIe quad insert/bypass switch with LC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
PXI/PXIe High Density 2A Multiplexer, 1-Bank, 64-Channel, 2-Pole
42-614D-016
Multiplexer Module
The 40-614D-016 (PXI) and 42-614D-016 (PXIe) 1-bank, 64-channel, 2-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI 2A Multiplexer, 4-Bank, 4-Channel 8-Pole
40-614-009
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
Keysight 70-Channel Reed Multiplexer for 34980A
34924A
Multiplexer Module
The Keysight 34924A module for the 34980A Multifunction Switch/Measure Unit is a high-density, high-speed multiplexer for general purpose scanning. It uses reed relays to achieve scan rates up to 500 channels-per-second. Use this module for high-throughput automated test applications as well as high-speed data logging and monitoring tasks.
-
Product
LXI Microwave Multiplexer, SP4T, 13-Bank, 50GHz, 50Ω, SMA-2.4
60-803-613
Multiplexer Module
Our 60-803-613 is a 13 bank SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-803 range is capable of supporting up to 16 banks of 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI 10A Power MUX, 5-Bank, 6-Channel
40-661-005
Multiplexer Module
The 40-661 is a single pole power multiplexer module, suitable for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. The multiplexer is available in 8-bank 4-channel, 5-bank 6-channel, 4-bank 8-channel, 2-bank 16-channel and 1-bank 32-channel formats. Also, 4-bank 4-channel, 2-bank 8-channel and 1-bank 16-channel half density configurations are available. Signal connections are made via front panel mounted 20-way GMCT plugs.
-
Product
PXI/PXIe MEMS Optical MUX, 8-Channel, Single-Mode, 9/125 Fiber, FC/PC Connectors
40-852A-118
Multiplexer Module
The 40/42-852A-118 is a PXI/PXIe 8-channel multiplexer with FC/PC connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
40 Channel Single-Ended Multiplexer Module for 34970A/34972A
34908A
Multiplexer Module
Use the Keysight 34908A module for the 34970A/34972A Data Acquisition/Switch Unit for the greatest density in common-low applications, such as battery test, component characterization, and benchtop testing. Each module switches 40 one-wire inputs. All two-wire internal measurements except current are supported. The module low connection is isolated from earth and can float up to 300 V.
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 1-Bank 26.5GHz SMA
60-802-301
Multiplexer Module
The 60-802-301 is a 4-channel, 1-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI High Voltage Power Multiplexer, Hex 4:1 (SP4T)
40-331A-004
Multiplexer Module
The 40-331A-004 hex 4:1 MUX is part of our range of 40-331A/332 High Voltage Power Multiplexer and Matrix Modules and is suitable for applications requiring high voltage power relay switching with high density. They feature current handling up to 5A, 1000VDC/1000VAC peak cold switching and 110VDC/250VAC hot switching.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP12T, 18 GHz, 50 Ω, SMA, Failsafe
40-788-221
Multiplexer Module
The 40-788-221 (PXI) and 42-788-221 (PXIe) are single failsafe SP12T 18 GHz unterminated microwave multiplexers. The 40/42-788 range of multiplexers are available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel. Remote versions are also available which can support one or two multiplexers in a dual slot module.
-
Product
PXI MUX 2 Banks of 64 Channel 1 Pole
40-610-022-2/64/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Single-Mode
40-850A-514
Multiplexer Module
The 40/42-850A-514 is a PXI/PXIe 4-channel multiplexer with ST connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
1x4 Multiplexer Plug-In
1260-134
Multiplexer Module
The Astronics1260-134 is a sixteen 1x4 multiplexer plug-in card for the Adapt-a-Switch® platform. It installs, easily and directly from the front panel, into the Adapt-a-Switch VXI Carrier, 1260-100.
-
Product
LXI Microwave Multiplexer, SP4T, 3-Bank, 18GHz, 50Ω, SMA
60-803-103
Multiplexer Module
Our 60-803-103 is a 3 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 18GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI 2A Multiplexer, 2-Bank, 16-Channel, 4-Pole
40-614B-012
Multiplexer Module
This 2-bank, 16-channel, 4-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI/PXIe MEMS RF Multiplexer, Quad 4-Channel, 4GHz, 50Ω, SMB
42-878-241
Multiplexer Module
The module is based on the latest micro-electromechanical system (MEMS) switching technology and has low insertion loss and VSWR. In addition, MEMS devices have a long operational life of >3 billion operations and benefit from an operating time of <20 μs allowing greater test system throughput. The multiplexers have excellent and repeatable RF characteristics beyond 4 GHz with each path having a nominally equal insertion loss.
-
Product
PCI 2 Amp Multiplexer, Single 8-Channel, 4-Pole
50-635A-103
Multiplexer Module
The 50-635A-103 is a single 8-channel, 4-pole MUX and is part of a range of PCI Multiplexer cards available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI Switched Guard Reed Relay Module, 16x 2:1 Multiplexer
40-121-011
Multiplexer Module
The 40-121-011 provides 16x 2:1 multiplexers in a single slot PXI module and designed to provide an isolation resistance in excess of 1013Ω. It has been designed to ensure high isolation resistance through the use of switched guards, making it ideal for low level measurements and semiconductor test.
-
Product
PXI Single 4 to 1 RF Multiplexer 2GHz 50 Ohm SMB Terminated
40-740-511
Multiplexer Module
40-740, 40-745 and 40-746 RF Multiplexers are a range of Bi-Directional Multiplexers with bandwidth up to 2000MHz. They are arranged as Single 8 to 1, Dual 4 to 1 or Single 4 to 1 configurations, all with excellent Insertion Loss, VSWR and Isolation, in 50 Ohm or 75 Ohm versions with a wide choice of connectors.
-
Product
LXI Microwave Multiplexer, SP6T, 11-Bank, 26.5GHz, 50Ω, SMA
60-800-311
Multiplexer Module
Our 60-800-311 is a 11 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 26.5GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PCI Very High Density Multiplexer, 49-Channel, 4-Pole
50-670C-022-49/4
Multiplexer Module
The 50-670C-022-49/4 is a 49-channel, 4-pole MUX and is part of a series of very high density multiplexer cards feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.The 50-670C shares exactly the same architecture as the established 40-670 range of PXI modules.