DC Power Supplies
Convert and provide Direct Current (DC) power to a device or group of devices.
See Also: Bipolar Power
-
product
EPM-P Series Dual-Channel Power Meter
E4417A
20 M sample/s per second sampling rate for reliable continuous and single shot measurements on wide bandwidth signals Time-gated and free run power measurements Free Analyzer Software software for complete pulse and statistical analysis, software is located In the Library8 pre-defined wireless configurations (GSM, EDGE, NADC, iDEN, Bluetooth, IS-95 CDMA, W-CDMA and cdma 2000)
-
product
Power, Patchcord, ITA, Mini Power, 36", 14 AWG White Teflon, Single Ended, (30 Amps)
7-241914000-036
Power, Patchcord, ITA, Mini Power, 36", 14 AWG White Teflon, Single Ended, (30 Amps).
-
product
Mini Power, Contact, Receiver, 65 Amp, 8 AWG
610116112
Primary mating contact 610115124. (May mate with other ITA contacts, as well.)Mini Power contacts carry up to 65 amperes continuous current. Maximum resistance is 1 Milliohms.Specifications Operating Current 65 Amps Max. Continuous – 8 AWG40 Amp Max. Continuous – 12 AWG30 Amp Max. Continuous – 14 AWG25 Amp Max. Continuous – 16 AWGContact Resistance 1 mOhms Max.Dielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 1000 MOhms Min.Contact Body BrassContact Plating 50µ" Au over 100µ" NiContact Termination SolderCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 3.37
-
product
Thermocouple Power Sensors
N8482H
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors.
-
product
Mini Power, ITA, 36", 50u Gold (22 Amps), 16 AWG White Teflon (19 Amps), Single-Ended
7-243916000-036
Mini Power, ITA, 36", 50u Gold (22 Amps), 16 AWG White Teflon (19 Amps), Single-Ended
-
product
Balance Thermocouple Power Sensor, DC To 50 GHz
N8487S
The Keysight N8480S Series Balance Thermocouple Power Sensors are intended to be used as measurement standards for RF power. They are suitable for use in a microcalorimeter-based primary measurement standard and as a secondary or reference measurement standard. The new balance thermocouple power sensors offer a broad frequency range DC up to 18/50 GHz, high maximum input power of +20dBm, fast measurement speed/settling time as well as ease of maintenance.
-
product
3U CompactPCI 8HP 16.6-160VDC Input Railway Power Module
cPS-H325/WDC
- PICMG® 2.11 CompactPCI® Power Interface compliant- 16.6 to 160VDC wide input range, 310W- 3U, 8HP CompactPCI package- EN 50155 Class S2 and C2 compliant for power stability- 40°C to 85°C operating temperature with deratin*g
-
product
DC System Power Supply, 8 V, 90 A, 720 W
N5742A
The single output, 720 W N5742A provides universal AC input, GPIB, LAN, USB, LXI compliance, and analog/resistance control of output voltage and current
-
product
Inline Optical Power Meter - PXI
Power 1600 Series
Quantifi Photonics’ Power 1600 Series inline optical power meters provides quick and accurate inline power monitoring. Seamlessly integrate the power meter into your new or existing PXI test setup and save space, lower your costs and improve testing efficiency.
-
product
Diode Power Sensor
8481D
The 8481D diode power sensor measures average power over the frequency range 10 MHz to 18 GHz and power range -70 to -20 dBm (50 dB dynamic range).
-
product
Power Module, 100V, 3A, 300W
N6776A
The Keysight N6776A is a 300 W basic DC power module that provides programmable voltage and current, measurement and protection features at a very economical price, making these modules suitable to power the DUT or to provide power for ATE system resources such as fixture control.
-
product
Custom Configured MPS, 600W
N6711C
The Keysight N6711C is a 600 W build-to-order system that is shipped as a fully tested and assembled multiple-output power supply. Each N6711C consists of 1 N6701C mainframe and from 1 to 4 DC power modules. Modules are ordered as options to the N6711C.
-
product
DC Power Module, 5V, 20A, 100W
N6741B
The Keysight N6741B is a 100 W basic DC power module that provides programmable voltage and current, measurement and protection features at a very economical price, making these modules suitable to power the DUT or to provide power for ATE system resources such as fixture control.
-
product
EPM-P Series Single Channel Power Meter
E4416A
The E4416A single channel EPM-P series power meter, for peak, average, peak-to-average ratio and time-gated measurements, using the E9320 peak and average power sensors.
-
product
Miniature 12G/3G/HD-SDI Fiber Transport
SilverBULLET Series
Sometimes you just need that “silver bullet” - a simple solution that solves problems. Maybe it’s a quick connection to support temporary video and audio feeds, or perhaps just a rock-solid fiber-optic connection for single-link transport to and from a camera. MultiDyne’s SilverBullet Series offers an economical solution for broadcast-quality signal transmission on single-mode fiber. At just three inches, the SilverBullet offers a compact, interlocking architecture to ensure robust links that can fit just about anywhere. SilverBullets come in a compact carrying case that includes the DC power supplies. Ideal for a wide variety of broadcast and professional AV applications including field production, remote camera links, courtesy feeds, cross-campus production and pre-fibered venues.
-
product
Thermocouple Power Sensors
N8481B
N8480 Series Power Sensors are the replacement solutions for 8480 Series Power Sensors.
-
product
100-Watt DC/DC Converter, 3U cPCI
55LQ2
NAI’s 55LQ2 is a 100 Watt DC/DC Converter that plugs directly into a standard 3U cPCI chassis with a 0.8” slot. It is conduction-cooled through the card edge/wedgelock. This modular, switching power supply accepts +28 VDC input and provides a single output at up to 100 Watts.
-
product
100W Dual Output Power Supply Two 35V, 1.4A or 60V, 0.8A
E3649A
Output ratings (@ 0C to 40C) 2 outputs Range 1: 0 to 35 V / 1.4 ARange 2: 60 V / 0.8 A Programming accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 10 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.2% + 10 mARipple & noise 20 Hz to 20 MHz Normal Mode Voltage: <8 mVpp / 1 mVrms Normal Mode Current: <4 mArms Common Mode Current: <1.5 uArms Readback accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 5 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.15% + 5 mA (<0.15% + 10 mA for output 2 of E3646/47/48/49A)
-
product
USB Power Sensor Module For Measuring Receiver
U5532C
The U5532C USB power sensor module is specially design for the N5531X measuring receiver. Based on the Keysight USB power sensor and a power splitter, the U5532C provides the N5531X measuring receiver user with a single RF input device covering up to 50 GHz. Using of the U5532C USB power sensor module eliminates the requirement of an external power meter, simplifying the setup process and saving lab space. The measurement integrity and accuracy are guaranteed by the fully defined specification sets. The traceability of measurement uncertainties is also ensured.
-
product
P-Series Single Channel Power Meter
N1911A
30 MHz video bandwidth Single shot real time capture at 100 M sample/s per second Key Measurements: - peak, average, peak-to-average ratio, rise time, fall time and pulse width22 Predefined formats: WiMAX, DME, HSDPA, etc. One screen view for pulse measurement analysis: Auto Scale, Auto Gate, Rise/Fall Time, Duty Cycle, etc. Internal Zeroing and Calibration while connecting to the DUT Bench Vue software enabled
-
product
Micro Power, Contact, ITA, 21 Amp, 12-14 AWG
610143101
Primary mating contact 610142101. (May mate with other Receiver contacts, as well.)Specifications Operating Current 21 amps continuousContact Resistance 1.5 mOhms max.Dielectric Withstanding Voltage (DWV) 1500 VDC min.Contact Body BrassContact Plating 30µ" Au over 100µ" NiContact Termination CrimpCycle Life 10,000 cyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 1.23u
-
product
10 MHz To 54 GHz LAN Wide Dynamic Range Average Power Sensor
L2056XA
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the internal zero and calibration function. The U/L2050/60 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform average power measurement and analysis.
-
product
Autoranging System DC Power Supply, 80 V, 340 A, 10000 W, 208 VAC
N8925A
The Keysight N8900 Series provides 5 kW, 10 kW, and 15 kW autoranging, single-output programmable DC power for ATE applications that require just the right amount of performance at just the right price. The N8900 Series power supplies' autoranging output characteristic enables unprecedented flexibility by offering a wide range of voltage and current combinations at full power. Power supplies with "rectangular," or traditional, output characteristics provide full power at only one voltage and current combination. Just one N8900 does the job of multiple power supplies. It's like having many power supplies in one!
-
product
10 MHz to 50/53 GHz LAN Wide Dynamic Range Peak and Average Power Sensor
L2065XA
The Keysight L2065XA is a fast, accurate and wide dynamic range 10 MHz – 50/53 GHz LAN peak and average power sensor.
-
product
10 MHz to 40 GHz LAN Wide Dynamic Range Average Power Sensor
L2054XA
The Keysight L2054XA is a fast, accurate and wide dynamic range 10 MHz – 40 GHz LAN average power sensor.
-
product
Power, Patchcord, Receiver, 36", Micro Power, 14 AWG White, Single Ended ( 22 Amps)
7-252914000-036
Power, Patchcord, Receiver, 36", Micro Power, 14 AWG White, Single Ended ( 22 Amps).
-
product
1,500-Watt AC/DC Power Supply, Air Plenum
56WS1-01
NAI’s 56WS1-01 is an air plenum-cooled, 1,500 Watt AC/DC Power Supply that converts either 3-phase, AC input or +270 VDC input into a single +28 VDC output at 1,500 Watts continuous or 3,000 Watts peak. This standalone device converts aircraft power so it can be used by system components.
-
product
DC Power Module, 60 V, 1.6 A, 100 W
N6745B
The N6745B is a 100 W programmable DC power module with basic features. For use in the N6700 low-profile Modular Power System or N6705 DC Power Analyzer.
-
product
10 MHz To 67 GHz LAN Wide Dynamic Range Peak And Average Power Sensor
L2067XA
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the internal zero and calibration function. The U/L2050/60 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform average power measurement and analysis.
-
product
Pulsed ESR/EPR: Pulsed Injection-locked IMPATT Amplifiers
Insight Product Company offers pulse injection-locked IMPATT amplifiers for pulse ESR/EPR experiments. Pulsed injection-locked amplifier incorporates IMPATT diode, ferrite input/output isolators, circulators, and pulse modulator. Only DC power supply, RF input signal, and external trigger signal are required to operate the amplifier. Output phase noise parameters are very close to the noise parameters of the input RF signal.