Rubidium Frequency Standards
See Also: Rubidium Standards
-
Product
Millimeter-wave Operation With Frequency Extenders For M980xA PXI VNA
S95560B
-
banded vector network analyzer (VNA) using the M980xA PXI VNAs and N5252AW or N5262BW Frequency Extenders.
-
Product
Frequency Extension Calibration Kits
FEK
-
Farran’s FEK-xx-0001 calibration kit provides accurate calibration of the Vector Network Analyzer (VNA). It is compatible with TRL and SOLT calibration techniques and allows for a full 12-term port calibration.
-
Product
2GHz programmable frequency dividerValon
3010a
-
The Valon 3010a accepts a wide range of input frequencies and provides three independent, user-selectable, divided outputs. The 3010a is useful for extending the low-frequency range of any signal source down to 5MHz as a 50Ω output or down to 0Hz as a TTL output.
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39T15-5.4
-
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Active Frequency Multipliers
-
The frequency multiplier which generates output signal with power greater than or equal to input power
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39H-5.4
-
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Standard 0.95 (26.90) - 4.50 (128.00) Battery Probe
CP-2TB-12
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 128Full Travel (mm): 3.25Recommended Travel (mil): 118.1Recommended Travel (mm): 3.00Overall Length (mil): 472Overall Length (mm): 12.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4L
-
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
Product
Standard Type Spring Probes
-
From for bare board to for ICT, we have variety of spring probes for PCB. In addition to variety of tip type and total length, we also have receptacles that match the best to spring probes. We can also attach lead wire to the receptacles.
-
Product
Standard Gain Horn Pyramidal Horn Antenna
-
Elva’s SGPH series of standard gain horn antennas cover the frequency range of 18 to 220 GHz in ten waveguide bands. They can be issued with rectangular or circular waveguide. Lens technology significantly allows decreasing mechanical sizes of horns and correcting beam for the best performance. These horns are ideal solution for measurement gain of other antennas, short range radars and radiometers.
-
Product
GFS Primary Gravimetric Flow Standard
-
The GFS dynamic gravimetric mass flow calibration system allows users to maintain the accuracy and traceability of molblocs or other high precision devices using the same primary reference used by Fluke Calibration. GFS is a true mass flow reference suitable for use in premier measurement institutes who require the lowest measurement uncertainty.
-
Product
MOSFETs For High Frequency Amplifier
-
The MOSFETs shown below are best suited for amplification of high-frequency signals.
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-2W1S
-
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Frequency generator
F170
-
The new F170 square wave frequency generator is based on the same hardware as the F165. It has all the features of the F165 plus 3 additional internal channels for a total of 6 programmable channels. It can run standalone up to 1500 program files copied from a PC or Mac or created from the keypad
-
Product
Wide Frequency Range High Resolution Tester
-
AllWin Instrument Science and Technology Co., Ltd.
Wide Frequency RangeHigh resolution and accuracyBIN measurementLoad compensationFrequency range:20Hz to 200kHz
-
Product
Frequency Converter Test Solution Up To 50 GHz
N5245BP
-
The N5245BP provides the N5245B 50 GHz PNA-X network analyzer, application software and accessories for frequency converter test up to 50 GHz. This bundle product
-
Product
Standard 1.00 (28.00) - 1.80 (51.00) General Purpose Probe
P2662BG-2V1S
-
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
Product
Standard IR Target Projectors
-
Santa Barbara Infrared’s 14000Zi Series reflective infrared target projectors are turnkey test systems for electro-optical (E-O) testing of FLIRs and other infrared (IR) imaging systems. The standard target projectors are assembled from SBIR’s STC Series Collimators, Infinity Blackbodies and 300 Series Target Wheels. SBIR also offers a standard athermal target projector with a 5.7° field of view (FOV).
-
Product
Frequency Counters
-
Handheld and bench-top frequency counters up to 6GHz Universal counters with VLF capability and pulse measurement and totalizing in addition to frequency/period.
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4J
-
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Switchable Fixed Frequency Synthesizer
EXP Series 2.25" x 2.25" x 0.6"
-
*Connectorized Package *Switches Between Multiple Fixed Frequencies *Exceptionally-Low Phase Noise *DRO Replacement *High Vibration Design
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40A
-
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
Low Frequency Test Systems
-
Ingenieurbüro Dr. Hillger Ultrasonic-Techniques
Our imaging low-frequency inspection systems are excellently suited to displaying internal defects with high resolution and high dynamics.
-
Product
Dual Frequency 900 kHz & 2250 kHz 2D Imaging Sonar
BlueView M900-2250-S 130/45-Mk2
-
The dual frequency M900/2250-S 130/45-Mk2 is a new configuration of the leading BlueView M900/2250 optimized for superb image quality in challenging shallow water environments. The 900 kHz offers high-resolution long range navigation, object detection, and obstacle avoidance, while the 2250 kHz provides ultra-high resolution at close range. ROV navigation, diver hand held, hull inspections, structure inspections, diver monitoring, and search and recovery are a few applications that benefit from the dual-frequency’s imaging capabilities. All M Series sonar operate while in motion or from a stationary position delivering real-time imagery and data.
-
Product
Standard 1.63 (46.00) - 4.50 (128.00) Battery Probe
CP-059-19
-
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 62Full Travel (mm): 1.57Recommended Travel (mil): 40Recommended Travel (mm): 1.02Mechanical Life (no of cyles): 100,000Overall Length (mil): 276Overall Length (mm): 7.01
-
Product
Standard 1.24 (35.00) - 2.94 (85.00) Battery Probe
CCA-006
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 78Full Travel (mm): 1.98Recommended Travel (mil): 40Recommended Travel (mm): 1.02Overall Length (mil): 669Overall Length (mm): 16.99
-
Product
High Voltage Standard
HVS
-
The HVS uses precision matched resistors for high accuracy; it is a modified Park divider structure.
-
Product
Hydrogen Frequency & Time Standard
CH1-1007
-
Hydrogen frequency and time standard Ch1-1007 is designed to generate and reproduce precision, highly stable, spectrally pure frequency and time signals. Main areas of application: – in metrology when transferring the sizes of units of frequency and time, including as part of mobile measuring complexes; – in radio astronomy when conducting scientific research; - in radio navigation when working as part of automated measuring systems and complexes.
-
Product
Standard 1.32 (37.40) - 4.50 (128.00) Battery Probe
CP-2LB-6
-
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 69Full Travel (mm): 1.75Recommended Travel (mil): 59Recommended Travel (mm): 1.50Overall Length (mil): 236Overall Length (mm): 6.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55





























