Product
Automation
50 Hz Adaptive Filter
-
One of the main causes of the reduction of accuracy in low frequency signal parameters measurements is the influence of artificial and natural electromagnetic interferences on measuring channels of measuring tools (MT). Under laboratory, production and natural conditions, the main interference is 50 Hz network interference. To eliminate this interference, ZETLAB software package uses a program providing a 50 Hz band-stop filter.
-
Product
Signal Amplifier
A10150
Amplifier
Model A10150 is an ultra-small footprint, wideband, DC coupled amplifier designed for high frequency, low distortion, signal amplification. With a high bandwidth of 150MHz, 20Vp-p into 50 ohms and a fast transition time of less than 1.8ns, the A10150 is the ideal complimentary amplifier to any high speed signal source that needs a supporting power boost for demanding applications.
-
Product
Impulsive Sound Source
BAS006
-
The BAS006 is an innovative device used to create impulsive noise that includes low frequency energy and avoids problems like secondary bounce. These characteristics make it a great choice for quickly measuring reverberation time when the complexity and weight of a speaker and amplifier is not needed.
-
Product
Vibrational Analysis
GEMINI-2
-
GEMINI-2 is the compact solution for HVSR, MASW and Vibrational Analysis: a single waterproof container with integrated high-performance 3D geophone and low resonance frequency (2Hz sensors, suitably coupled) and a powerful real 24-bit acquisition card with USB port for connection to an external PC.
-
Product
Bearings Vibration Meter
HG-2510
-
DETECTING VIBRATION INTENSITY OF EQUIPMENT Vibration Detection of Machinery Equipment Hitches of rotary machinery will result in abnormal vibtation. Increasing of low frequency vibration intensigy can be caused by unbalance of rotor, nonaxiality of rotating axis,looseness of base and iol membrane vibration of bearings.
-
Product
RF Adapters
UHF Adapters
-
Are general purpose units developed for use in low frequency systems from 0.6 - 300 MHz.
-
Product
Electromagnetics
-
Altair software is used across industries to solve a broad range of electromagnetic problems from static to low and high frequencies. Whether your application requires multiple frequency and time-domain techniques with true hybridization to enable efficient exploration of a broad spectrum of electromagnetic performance, or the simulation of magneto static, steady-state and transient conditions, we have the tools you need.
-
Product
500 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP018-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Phase Locked Oscillators
-
Phase locked oscillators (PLO) utilize state-of-the-art planar circuits, three-terminal devices and dielectric resonator technology to generate high-quality microwave signals at lower frequencies. Frequency multipliers, amplifiers and filters are used to extend the low frequencies for higher frequency requirements. The standard offering covers the frequency range of 2 to 110 GHz and provides both internal and external reference options. The frequency stability and phase noise are dependent on the oscillator reference type.
-
Product
LCR Meter
TH2810B+
-
Changzhou Tonghui Electronic Co., Ltd.
■ Freq: 100Hz,120Hz, 1kHz, 10kHz 4 points ■ Test Accuracy: 0.1% ■ Test Speed: Max.19ms, support low frequency and high speed:TX4+3ms
-
Product
Ferrite Low Frequency Transducers
-
Ceramic magnetic design able to provide high-power handling and low distortion for the most demanding speaker manufacturers.
-
Product
High-speed Dual-channel 2D GPR
CrossOver
-
First dual-channel RTS (Real-Time Sampling technology) antenna. The dual-channel configuration provides you with both low and high frequency bands in one package, making it possible to cover a broad range of applications with only one instrument. RTS-based GPR antenna designs have already proven their effectiveness against conventional designs in relation to performance improvements (increased dynamic range, sensitivity, and depth penetration).
-
Product
AC Current Sensor
LFR
-
The LFR ac current probe has been designed to have market leading low frequency performance, meaning low phase shift and low noise. This compact, low cost, clip-around probe is both flexible and dual-range, and is optimized to give minimal phase measurement error at frequencies from 45Hz to 20kHz and have a very low noise floor.
-
Product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP025-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
LAN Cable Tester
PA-01D
-
The LAN cable tester is a versatile, full-featured tool for testing many kinds of network cable. Loopback and remote tests may be performed automatically or manually, and will test cable continuity as well as identifying opens, shorts, reversed wiring, and miswiring in cables up to 2,000 ft. long. Shielded connectors allow the tester to test shielded twisted pair (STP) cables. The built-in tone generator generates a low emission frequency tone which can be detected by any market tone probe, making it easier to trace and locate cables. Uses 1 9V alkaline battery. CE Approved.
-
Product
Precision Capacitance Meter
TH2638B
-
Changzhou Tonghui Electronic Co., Ltd.
TH2638 series is a new precision capacitance meter with higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. With basic accuracy of ±0.07%, loss accuracy of 0.0005, test frequency up to 1MHz, 4.3-inch LCD screen, selectable Chinese-English operation interface, TH2638 series is easy to operate and provide fast and reliable test for ceramic capacitor production. Also, it can test all kinds of capacitors from low value to high value. The results of testing one capacitor for several times are quite stable and accurate, even for lower value capacitors. The tester is compatible with SCPI command set, and configured with manipulator and scanner interface, the scanner interface can scan the open/short/ load error calibration in each channel, 256 channels at most. In low frequency, there is signal level compensation function. When the impedance is very small, the internal resistance in signal source and test cable will cause the voltage on terminal of DUT lower than the set range, then this function will adjust the level to the set range.
-
Product
250 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP017-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Series Low Frequency Vibration Sensors
AC136
-
Low Frequency Accelerometer, Side Exit Connector / Cable, 500 mV/g
-
Product
Low Frequency RF Broadband Power Sources
-
Class A has RF power source, ideal for Industrial /Scientific / Medical applications. Class AS is a robust source of RF power for ultrasonic, laser modulation, RFI/EMI, plasma generation, general laboratory and industrial applications.
-
Product
DM 150-Watt Transmitter
Loc-150Tx
-
The Loc-150Tx, 150-Watt DM Transmitter is used primarily with the Defect Mapper (DM) Receiver, however it is also useful for those needing a low frequency, high output transmitter. Typically, the Loc-150Tx, transmitter (DM transmitter) is used to apply a signal current to the anode bed. The pipeline returns the signal via coating faults back to the transmitter. The Loc-150Tx transmitter is designed to be powered from CP (Cathodic Protection) stations, AC or external batteries, eliminating the need for internal batteries. This transmitter has a direct connection mode to apply the locate frequency onto the conductor. There is no clamp or induction mode.
-
Product
RFID
LF (70/455 kHz)
-
BIS C works with low frequency (LF) and uses two frequencies: 455 kHz for writing and 70 kHz for reading. The wide variety of passive data carriers with various dimensions, configurations, memory sizes, operating temperatures, materials, mounting options and ranges allows you to tackle nearly any technical task. BIS C established as the standard for tool identification.
-
Product
Turned Log Peri Antenna
MOLP80-1000M
-
This is Antenna for IEC61000-4-3 Radiation Immunity Test. Unique Structure with turned Element increase the GAIN at the low frequency. Stew structure of 22 and can be fitted to normal Antenna MAST.
-
Product
Handheld spectrum analyzer/Signal analyzer
-
Recently, a lot of equipment have taken the high frequency or microwave technology according to the advancement and the spread of the telecommunication equipment. As a result, the handheld spectrum analyzer to analyze the signal by the frequency domain is necessaries now. The handheld spectrum analyzer is roughly classified into a heterodyne method and a Fourier transform method. The heterodyne method is also called the swept frequency method and makes it possible to measure up to tens of GHz though only for the steady signal. On the other hand, the Fourier transform method is also called the real time method and can handle an unsteady signal though the low measuring frequency range up to tens of MHz. As for our spectrum analyzer or signal analyzer, the MSA300/400 series adopts the swept frequency method, and the MSA500 series adopts both the swept frequency method and the Fourier transform method.
-
Product
XCITE 1100 Laboratory Series
-
The Xcite 1100 Laboratory Series is the most popular of the Xcite product line because of its large force capacity and broad frequency range compared to its extremely compact size. The 5 GPM 3-Phase hydraulic power supply used in the system provides a high level of low frequency displacement response for testing system subassemblies and non-linear structures such as suspensions and elastomeric dampers. The small piston area of the exciter and the high performance servovalve combine to provide excitation to over 1000 Hz allowing structure borne noise path evaluations.
-
Product
Passive Probes
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a /10 attenuation and feature a high input resistance of 10 MOhm. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400 V, some as high as 600 V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
1 / 2 / 3 MHz Multi-Waveform Signal Generator
MSG1M / MSG2M / MSG3M
-
- Wide frequency range- Sine, triangle, square, ramp, pulse, TTL (Sync) & DC outputs- Low distortion high resolution on low frequency output attenuation up to 80dB- Variable DC offset control- Four digit digital display with frequency indication in Hz, KHz, MHz/Amplitude display
-
Product
LCR Meter
TH2811D
-
Changzhou Tonghui Electronic Co., Ltd.
TH2810D/TH2811D LCR meter is our newly developed successor instrument for low frequency component measurement. TH2810D/TH2811D with its latest measurement technologies, large character LCD display, surface mount technics, easy of use and excellent appearance can be used for quality control on production line, incoming inspection of components and automatic test system. The RS-232C interface can be used to carry out remote control and statistics and analysis of measurement results.
-
Product
XCITE 1200-2 Inertial Mass Excitation System
-
The Xcite 1200-2 Inertial Mass Excitation system provides a new dimension to structural testing. The ES-302 Exciter contains a 250 lb mass which is accelerated through a 2″ displacement by a hydraulic actuator. The 2,000 lb inertial force which is generated provides ample input to structures such as those shown below to perform low frequency seismic studies and high frequency rotating equipment analyses.
-
Product
FFT Analyzer Software Modules
-
Metra Mess- und Frequenztechnik in Radebeul e.K.
*Vibration analyzer for low and middle frequencies*Calculates the spectrum of vibration acceleration*VM-FFT+ also for velocity and displacement*RMS and peak spectrum*Envelope spectrum for roller bearing analysis with VM-FFT+*Limit curve with external alarms in VM-FFT+*Power spectral density (PSD) with VM-FFT+*Two measuring cursors for magnitudes and frequencies with snap-in function*Up to four signals per window*One VM-FFT license can be operated simultaneously up to four times with different settings*VM-SCOPE may trigger the frequency analyzer module VM-FFT*External messengers *Offline measurement
-
Product
Very Low Frequency Control Element
VLFC
-
Think extremely low. With a range of 13-30 Hz—the lowest reach of any Meyer Sound speaker—the VLFC extends below the threshold of human hearing to let your audience feel the sound like never before.