Waveform Signal Generators
See Also: Waveform Generators, Arbitrary Waveform Generators
-
Product
Signal, Contact, Receiver, QuadraPaddle, 5 Amp, Twin Female
610138200
Signal Contact (Receiver)
Primary mating contact 610138118. (May mate with other Male Adapter and ITA contacts, as well.)
-
Product
Signal, Patchcord, Receiver, 72", TriPaddle, 22 AWG, Single Ended ( 5 Amps)
7-104922000-072
Signal Patchcord
Signal, Patchcord, Receiver, 72", TriPaddle, 22 AWG, Single Ended ( 5 Amps).
-
Product
Signal, Patchcord, Receiver, 72", QuadraPaddle, 22 AWG White, Single Ended (5 Amps)
7-124922000-072
Signal Patchcord
Signal, Patchcord, Receiver, 72", QuadraPaddle, 22 AWG White, Single Ended (5 Amps).
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74A
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Alternate 2.52 (71.00) - 6.50 (184.00) General Purpose Probe
EPA-3T-1
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.10 (31.00) - 3.85 (109.00) General Purpose Probe
HPA-64-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3,9,10: 0,365″; Tip 8: 0,385″
-
Product
Ethernet/LXI generatorNETBOX 16 Bit Arbitrary Waveform Generator - up to 40 MS/s on 24 Channels
DN6.653-24
Arbitrary Waveform Generator
The generatorNETBOX DN6.65x arbitrary waveform generators (AWG) is a general purpose multi-channel AWG with outstanding dynamic performance. The series includes LXI units with either up to 48 synchronous channels. The large onboard memory can be segmented to replay different waveform sequences.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2C40
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35 Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3C
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Dual Channel 100 MHz Pulse Generator
PXIe-1209
Pulse Generator
The Astronics Test Systems PXIe-1209 PXI is a high-performance, 2-channel, 100 MHz Pulse Generator. Occupying a single PXI Express peripheral slot or hybrid slot, the PXIe-1209 provides dual independent pulse generation with fullcontrol of all timing parameters with extremely high resolution.
-
Product
Cup Reduced Concave, Alternate 0.78 (22.00) - 3.70 (105.00) General Purpose Probe
HPA-0G12-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Signal, Patchcord, ITA, 36", TriPaddle, 26 AWG Twisted Pair White/Black, Single Ended (1.5 Amps)
7-105426000-036
Signal Patchcord
Signal, ITA, TriPaddle (7 Amps) 26 AWG Twisted Pair White/Black (1.5 Amps)
-
Product
Alternate 2.64 (75.00) - 6.50 (184.00) General Purpose Probe
EPA-2J30-1
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Ultra High 4.09 (116.00) - 10.00 (283.00) General Purpose Probe
EPA-2X-2
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Alternate 1.00 (28.00) - 2.00 (57.00) General Purpose Probe
P2663G-1W2S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
Product
PXIe-5663E, 6.6 GHz PXI Vector Signal Analyzer
781260-01
Signal Module
6.6 GHz PXI Vector Signal Analyzer - The PXIe‑5663E offers wide instantaneous bandwidth and supports RF list mode, which increases multiband measurement speed with fast and deterministic changes in configuration. You can use a PXIe‑5663E as either a spectrum analyzer or vector signal analyzer, and you can use it with the Modulation Toolkit to analyze custom and standard modulation formats. The PXIe‑5663E can perform measurements for a broad range of communications standards such as GSM, EDGE, WCDMA, WiMAX, LTE, Bluetooth, WLAN, DVB‑C/H/T, ATSC, and MediaFLO. Because all measurements are software defined, you can reconfigure the measurements using standard-specific toolkits. With these toolkits, the PXIe‑5663E provides a low-cost solution to high-performance RF measurements.The PXIe-5663E comprises the following modules:• PXIe-5601 RF Signal Downconverter• PXIe-5622 IF Digitizer• PXIe-5652 RF Analog Signal GeneratorThere is no physical device named "PXIe-5663E".
-
Product
Alternate 2.64 (75.00) - 6.50 (184.00) General Purpose Probe
EPA-2B40-1
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
2.5GS/s 16Bit 2GS Mem 4CH Arbitrary Waveform Generators
P2584B
Waveform Generator
The Proteus P2584B, is a 2.5GS/s, four channel arbitrary waveform generator packaged in a 4U, 19” standalone box with a 9” touch screen and on board PC , offering technologically advanced options and configurations that integrate the ability to transmit, receive and perform digital signal processing all in a single instrument. The P2584B offers industry leading performance Including an innovative task oriented programming, real time data streaming, fast feedback loop for environment dependent waveform generation and user customizable FPGA for application specific solutions.
-
Product
CXA-m PXIe Signal Analyzer
M9290A
Signal Analyzer
Deploy a smaller microwave footprint, no trade-off in precision: Rely on fully specified performance up to 26.5 GHz in 4 slots Optimize your balance between speed, sensitivity and accuracy with the choice to operate in swept or FFT modes Perform fast calibrated stimulus response measurement with full-band tracking generator Smooth the transition between R&D, manufacturing, and maintenance: CXA-m is code compatible with benchtop X-Series signal analyzers and ESA spectrum analyzers
-
Product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5A
General Purpose Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
Product
Pyramid, 3-Sided Chisel 30°, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0T
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
PXIe-5665, Up to 14 GHz PXI Vector Signal Analyzer
781426-03
Signal Module
Up to 14 GHz PXI Vector Signal Analyzer - The PXIe‑5665 is a modular, three‑stage superheterodyne analyzer that you can use as either a spectrum analyzer or vector signal analyzer. It supports RF list mode, which increases multiband measurement speed with fast and deterministic changes in configuration. In addition, you can use the PXIe‑5665 with the Modulation Toolkit to analyze custom and standard modulation formats. The PXIe‑5665 can perform measurements for a broad range of communications standards such as GSM, EDGE, WCDMA, WiMAX, LTE, Bluetooth, WLAN, DVB‑C/H/T, ATSC, and MediaFLO. Because all measurements are software defined, you can reconfigure the measurements using standard-specific toolkits. With these toolkits, the PXIe‑5665 provides a low-cost solution to high-performance RF measurements.
-
Product
Alternate 3.50 (99.00) - 6.85 (194.00) General Purpose Probe
P2757G-1V2S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Ultra High 4.09 (116.00) - 10.00 (283.00) General Purpose Probe
EPA-2P-2
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
HPA-1 General Purpose Probes
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Signal, Patchcord, ITA, 36", TriPaddle, 24 AWG Twisted Pair White/Black, Single Ended (3 Amps)
7-103424000-036
Signal Patchcord
Signal, Patchcord, ITA, 36", TriPaddle, 24 AWG Twisted Pair White/Black, Single Ended (3 Amps).
-
Product
Waveform Function Generators
-
Teledyne Test Tools generate fixed or arbitrarily defined waveforms and signals for use in the development, testing and repair of electronic systems.
-
Product
Alternate 1.00 (28.00) - 2.00 (57.00) General Purpose Probe
P2663G-1C2S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
Product
EXA Signal Analyzer, Multi-touch, 10 Hz to 44 GHz
N9010B
Signal Analyzer
Address diverse needs with the fast, flexible EXA Get the most cost-effective analysis for millimeter-wave measurements Measure the smallest signals in the presence of large ones with best-in-class level accuracy, DANL & TOI Perform power measurements quickly at discrete frequency points with list-sweep mode
-
Product
Arbitrary Waveform Generator
M8199A
Arbitrary Waveform Generator
Get the highest sample rate and the widest bandwidth arbitrary waveform generator in its class with up to four synchronized channels operating simultaneously in one module.