Waveform Signal Generators
See Also: Waveform Generators, Arbitrary Waveform Generators
-
Product
PXI-5406, 14/16-Bit, 20/40 MHz Arbitrary Function Generator
779657-01
Waveform Generator
40 MHz Bandwidth, 16-Bit PXI Waveform Generator—The PXI‑5406 is a 40 MHz function generator capable of generating standard functions including sine, square, triangle, and ramp as well as other signals like psuedorandom noise and DC signals. This function generator can generate signals from -5 V to +5 V and uses direct digital synthesis (DDS) to precisely generate waveforms.
-
Product
PXIe-5820, 500 MHz, 1 GHz I/Q Bandwidth, Baseband PXI Vector Signal Transceiver
783967-01
Vector Signal Transceiver
500 MHz, 1 GHz I/Q Bandwidth, Baseband PXI Vector Signal Transceiver—The PXIe‑5820 is the baseband model of the second-generation vector signal transceiver (VST) with 1 GHz of complex I/Q bandwidth. It combines a wideband I/Q digitizer, wideband I/Q arbitrary waveform generator, and high-performance user-programmable FPGA in a single 2-slot PXI Express module. You can use the VST for a variety of applications including baseband I/Q test of wireless and cellular chipsets; envelope tracking of digitally predistorted waveforms for power amplifiers; and the generation and analysis of new wireless standards such as 5G, 802.11ax, and LTE-Advanced Pro.
-
Product
Radius, Alternate 0.78 (22.00) - 3.70 (105.00) General Purpose Probe
HPA-0D-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Alternate 1.30 (37.00) - 4.50 (128.00) General Purpose Probe
HPA-1T-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Signal, Contact, ITA, TriPaddle, 10 Amp, 14 AWG
610110147
Signal Contact (ITA)
Signal, Contact, ITA, TriPaddle, 10 Amp, 14 AWGThis contact primarily used in CASS applications.Operating Voltage & Current 10 Amps Max. Continuous (14 AWG)Contact Resistance 4 mOhms Max.Measured at 50 mV @ 100 mAContact Body BrassContact Plating 50µ” Au over 100µ” NiContact Termination Crimp/SolderCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation Compliant
-
Product
Alternate 3.20 (90.00) - 6.90 (196.00) General Purpose Probe
EPA-4J-1
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
PXI Multi-Channel Function Generator Module, 32-Channel
41-625-001
Function Generator
The 41-625-001 (PXI) and 43-625-001 (PXIe) are function generator modules that provide 32 channels in a single PXI/PXIe slot. They can generate sine waves to 300 kHz with 5.76 mHz frequency resolution referenced to the 10 MHz PXI clock. The output voltage range is up to +/-25 V in a 16-bit resolution. It also support PXI trigger functions allowing events from other instruments to initiate waveform generation or sweeps.
-
Product
Standard 2.00 (57.00) - 4.00 (113.00) General Purpose Probe
P2757G-1V1S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Alternate 2.82 (80.00) - 5.00 (141.00) General Purpose Probe
HPA-74C-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Standard 1.00 (28.00) - 1.80 (51.00) General Purpose Probe
P2662BG-2V1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4H
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
PCIe LVDS Digital Waveform Acquisition - 720 MBit/s Internal Sampling Rate Timing, 700 MBit/s External State Clock
M4I.7735-X8
Digital Waveform
The M4i.77xx-x8 series digital waveform acquisition (logic-analyzer) cards include versions with 32 synchronous channels, either single-ended with programmable threshold levels or differential. The large onboard memory can be segmented to record different waveform sequences. While the M4i.77xx cards have been designed using the latest technology they are still software compatible with the drivers from earlier Spectrum digital acquisition cards. Therefore existing customers can use the same software they developed for a 10 year old 60 MS/s digital input card also for an M4i.77xx series 720 MS/s logic analyzer.
-
Product
Signal, Contact, ITA, QuadraPaddle, 5 Amp, 26-30 AWG
610138112
Signal Contact (ITA)
Primary mating contact 610138116. (May mate with other Receiver contacts, as well.)Available in twin-female, crimp/solder, twin male, and wire-wrap design, QuadraPaddle contacts are engineered for flexible interconnect options. Rated at 5 amps continuous (1250 VAC) with a 2 ounce insertion force, QuadraPaddle contacts provide 4 reliable points of contact per pin, outstanding electrical performance, and low mating force.Specifications Operating Voltage & Current 5 Amps Max. Continuous; 600 volt Max. use of wire Mil-W-16878/4Contact Resistance 25 mOhms Max.Measured at 50 mV @ 100 mADielectric WithstandingVoltage (DWV) 1500 VDC Min.Insulation Resistance 5000 MOhms Min.Contact Body BrassContact Plating 30µ” Au over 100µ” NiContact Termination Crimp/SolderCycle Life 20,000 CyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 0.24
-
Product
PCI-5412, 100 MS/s, 14-Bit Waveform Generator Device
779177-01
Waveform Generator
The PCI‑5412 can generate user-defined, arbitrary waveforms and standard functions, including sine, square, triangle, and ramp. This arbitrary waveform generator can generate signals from -6 V to +6 V and uses direct digital synthesis (DDS) to precisely generate waveforms.
-
Product
PXIe-6544, 100 MHz, 32-Channel, 3.3 V PXI Digital Waveform Instrument
780992-03
Digital Waveform
PXIe, 100 MHz, 32-Channel, 3.3 V PXI Digital Waveform Instrument—The PXIe‑6544 is a digital waveform generator and analyzer for interfacing with 32 single-ended digital pins. The PXIe‑6544 can sample digital waveforms at up to 100 MHz and interface with common transistor‑to‑transistor logic (TTL) voltage levels. The PXI‑6544 also features advanced synchronization capabilities for building integrated mixed-signal test systems and per-bank digital timing features.
-
Product
EXA Signal Analyzer, Multi-touch, 10 Hz to 44 GHz
N9010B
Signal Analyzer
Address diverse needs with the fast, flexible EXA Get the most cost-effective analysis for millimeter-wave measurements Measure the smallest signals in the presence of large ones with best-in-class level accuracy, DANL & TOI Perform power measurements quickly at discrete frequency points with list-sweep mode
-
Product
PXIe-5665, Up to 14 GHz PXI Vector Signal Analyzer
781775-03
Signal Module
Up to 14 GHz PXI Vector Signal Analyzer - The PXIe‑5665 is a modular, three‑stage superheterodyne analyzer that you can use as either a spectrum analyzer or vector signal analyzer. It supports RF list mode, which increases multiband measurement speed with fast and deterministic changes in configuration. In addition, you can use the PXIe‑5665 with the Modulation Toolkit to analyze custom and standard modulation formats. The PXIe‑5665 can perform measurements for a broad range of communications standards such as GSM, EDGE, WCDMA, WiMAX, LTE, Bluetooth, WLAN, DVB‑C/H/T, ATSC, and MediaFLO. Because all measurements are software defined, you can reconfigure the measurements using standard-specific toolkits. With these toolkits, the PXIe‑5665 provides a low-cost solution to high-performance RF measurements.
-
Product
Cup, Concave 90/120 degree, Alternate 0.78 (22.00) - 3.70 (105.00) General Purpose Probe
HPA-0A-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Signal, Contact, ITA, TriPaddle, 7 Amp, .025" Square Post for Wire Wrap
610110113
Signal Contact (ITA)
Primary mating contact 610110177. (May mate with other Receiver contacts, as well.)Plated with 30µ" gold.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1L
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Alternate 3.00 (85.00) - 5.70 (162.00) General Purpose Probe
P2664G-1C2S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50G
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
Signal, Patchcord, Receiver, 72", QuadraPaddle, 22 AWG White, Twisted Pair ( 5 Amps)
7-124439000-072
Signal Patchcord
Signal, Patchcord, Receiver, 72", QuadraPaddle, 22 AWG White, Twisted Pair ( 5 Amps)
-
Product
Alternate 3.50 (99.00) - 6.85 (194.00) General Purpose Probe
P2757G-1W2S
General Purpose Probe
Current Rating (Amps): 20Average DC Resistance lower than (mOhm): 10Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,210Overall Length (mm): 30.73Overall Length Remark: Tip 2C: 1140 mil (28.96 mm) Tip 1W: 1205 mil (30.61 mm) Tip 2W: 1205 mil (30.61 mm)
-
Product
Alternate 1.00 (28.00) - 2.00 (57.00) General Purpose Probe
P2663G-1W2S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
Product
PXIe 16 Bit Arbitrary Waveform Generator - up to 1.25 GS/s on 2 Channels
M4X.6631-X4
Arbitrary Waveform Generator
The M4x.66xx-x4 series arbitrary waveform generators (AWG) deliver the highest performance in both speed and resolution. The series includes PXI Express (PXIe) cards with either one, two or four synchronous channels. The large onboard memory can be segmented to replay different waveform sequences. The AWG features a PCI Express x4 Gen 2 interface that offers outstanding data streaming performance. The interface and Spectrum’s optimized drivers enable data transfer rates in excess of 2.8 GB/s so that signals can continuously replayed at a high output rate. While the cards have been designed using the latest technology they are still software compatible with the drivers from earlier Spectrum waveform generators. So, existing customers can use the same software they developed for a 10 year old 20 MS/s AWG card and for an M4x series 625 MS/s AWG.
-
Product
64-Channel Form A General Purpose Switch for 34980A
34939A
General Purpose Switch
The Keysight 34939A is a high density general-purpose switch module for the 34980A Multifunction Switch/Measure Unit. It has 64 independent single-pole, single-throw (SPST) relays that can switch 1A and carry 2A. This module can be used to cycle power to products under test, control indicator and status lights, and to actuate external power relays and solenoids. The relays are 100V, 1A contacts and can handle up to 60W. Standard 78-pin Dsub connectors allow for use with standard cables, screw terminal blocks, or mass interconnect solutions.
-
Product
PXI-2514, 7-Channel, 40 A PXI Signal Insertion Switch Module
778572-14
Signal Module
7-Channel, 40 A PXI Signal Insertion Switch Module—The PXI‑2514 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2514 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
Product
Replaceable General Purpose Probe
MEP-30
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 30Test Center (mm): 0.76Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 690Overall Length (mm): 17.53





























