Probing
See Also: Probers, Probing Stations, Nano Probes
-
product
Microwave Testing
50A
The GGB Industries, Inc., MODEL 50A probe sets new standards in microwave probing performance. Using low loss coaxial techniques, the Model 50A achieves an insertion loss of less than 1.0 db and a return loss of greater than 18 db through 50 GHz.
-
product
Standard 1.68 (48.00) - 3.20 (91.00) General Purpose Probe
HPA-52B
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 250,000Overall Length (mil): 629Overall Length (mm): 15.98
-
product
Manual Test Fixture (MA)
MA 2013/D/H/VPC-G12x-18
Parallel contact stroke: 15 mmContact force max.: 2000 NInterface block required: NoInterface signals max.: 1700Component on PCB: 58 mmPressure frame unit-opening angle: 75Installation height test probe top: 16,0 mmInstallation height test probe bottom: 10,5 mmInstallation height dual-stage test probe bottom: 16,0 mmweight: 25,00 kg
-
product
POGO-25HM-4 Probe
POGO-25HM-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 2,000,000Overall Length (mil): 1300Overall Length (mm): 33.02
-
product
Corrosion Analysis
Resipod
Resipod is a fully integrated 4-point Wenner probe, designed to measure the electrical resistivity of concrete in a completely non-destructive test. It is the most accurate instrument available, extremely fast and stable and packaged in a robust, waterproof housing designed to operate in a demanding site environment. The Resipod is the successor of the classic CNS Farnell Resistivity Meter.Surface resistivity measurement provides extremely useful information about the state of a concrete structure. Not only has it been proven to be directly linked to the likelihood of corrosion and the corrosion rate, recent studies have shown that there is a direct correlation between resistivity and chloride diffusion rate and even to determination of early compressive strength. This makes it one of the most versatile NDT methods for concrete.
-
product
H.V. Probes
PD-28
Standard Electric Works Co., Ltd
● Measures both AC and DC voltages with digital multitester.● Are typically used to measure high voltages in TV sets, power supplies and instruments in laboratories.● Lightweight and rugged.● 2 available contact tips: round needle tip for normal use and a special flat spring-type for CRT anode.
-
product
High Voltage Probe
HVP-40M
*DC 40KV CAT II Pollution 2*600MΩ Impedance*25KV ± 2%, 40KV ± 3%*T.C. 200 ppm/oC*Positive Polarity only.*Resolution 1KV*Need not power.*CE, TUV GS, UL, CUL, IEC1010
-
product
Residential/Commercial Combustion Analyzer w/ NOx Sensor
C165+N
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C165+ Residential/Commercial Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and differential pressure. Prints to optional printer and wireless App. The new LINK feature connects the included wireless pipe clamp temperature probes and other optional probes to the C165+. Essential information for installing and maintaining furnaces and boilers all in one device.
-
product
High Force Type Probe For PCB, K100 Series 100mil Pitch, Type G, Ø1.50mm, 155gf
K100-G150155-SKAU
K100 Series, Pitch 100mil, Tip Style G, Tip Diameter Ø1.50mm, Spring force 155gf, Steel with Gold Plating.
-
product
Test Probes
Our innovative Test Probes are the upgrade version of Auto Multi Meter. It can perform multiple circuit system test such as power supply feed, voltage and resistance measurement, continuity test, ground test, polarity check and components activation.
-
product
High 1.73 (49.00) - 8.00 (127.00) High Performance Lead Free Probe
LFRE-1L-8
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Debug Probes
J-Link and J-Trace
SEGGER Microcontroller GmbH & Co. KG
SEGGER J-Links are the most widely used line of debug probes available today. They've been proven for more than 10 years with over 250,000 units sold, including OEM versions and on-board solutions. This popularity stems from the unparalleled performance, extensive feature set, large number of supported CPUs, and compatibility with all popular development environments.
-
product
ITA, I2 Micro ICon, 168 Position
410130101
The i2 Micro iCon ITA is capable of holding up to 168 QuadraPaddle contacts. Its sleek, 0.8” footprint increases the horizontal stackability. The 30 degree U-shaped cable clamp allows ITA modules to be pre-wired before assembly and can hold cable bundles with an oblong bushing effective diameter of 0.77 in. The removable cover allows easy access to wiring for maintenance and probing. Integrated spring locking tabs ensure even and secure engagement.
-
product
Web Sensor
P8511
Web Sensor P8511 is designed to connect one probe. To Web Sensor P8541is possible connect up to four probes. Temperature or humidity probes are available asoptional accessories
-
product
Infrared Thermometers
Two specifications tell you nearly everything you need to know about any infrared (laser) thermometer: its measurement range and its distance-to-spot (D:S) ratio. The wider the range and the higher the D:S number (a measure of its optical resolution), the better the instrument. Infrared Thermometers (IRTs) with lower numbers are perfectly adequate for simple tasks like spot-checking food temperatures and energy auditing such as the IRT207 Non-Contact Infrared Thermometer. Higher-priced infrared thermometers intended for industrial users may have a SKU that ends in "K" such as the IRT850K Ultra-Wide-Range Infrared Thermometer with K Port and Adjustable Emissivity. The "K" indicates that it can accept inputs from a "K" type thermocouple probe used to measure temperature on-contact.
-
product
4.0mm Hazardous Live Parts Probe
CX-A4D
Shenzhen Chuangxin Instruments Co., Ltd.
Used to verify protection against access to hazardous parts through top openings. Meets IEC, EN, UL and CSA Standards including IEC 1010, EN61010-1, UL3101-1, and CSA 1010-1. The handle and stop face are made of Delrin. The rod is made of stainless steel.
-
product
High 2.90 (82.20) - 12.60 (357.00) Switch Probe
TSP100-H150-3
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
2 inputs Centesimal Thermometer Pt100
HD2127.1
Centesimal thermometer in the range ±199.99 °C, decimal outside this range, 2 inputs for Pt100 probes with SICRAM module. Measuring range -200 °C…+650 °C.
-
product
Surface Roughness Meters
This instrument is compatible with four standards of site to measure surface roughness of various machinery-processed parts, calculate corresponding and clearly display all measurement parameters.When measuring the roughness of a surface, the sensor is placed on the surface and then uniformly slides along the surface by driving the mechanism by the sharp built-in probe. This roughness causes displacement of the probe which results in change of inductive amount of induction coils so as to generate analogue signal, which is in proportion to the surface roughness at output end of phase-sensitive rectifier.
-
product
Water Conductivity and Temperature Probe
CS547A-L
The CS547A is a water quality probe that measures both electrical conductivity (EC) and temperature. It connects to a Campbell Scientific datalogger via the A547 interface. This probe is compatible with most Campbell Scientific dataloggers.
-
product
Ultra High 1.77 (50.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-25J-10
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Power Integrity Analyzer Reference Solution
The power integrity analyzer reference solution is a hardware-based solution with the Keysight Infiniium S-Series 10-Bit ADC oscilloscope and probes, including the N7020A power rail probe that lets you see the true AC power noise on your DC power line and supports up to +/- 24 V offset and the N2820A high-sensitivity current probe that can measure down to 50 uA.
-
product
Calibration Baths
Calibration baths are electronic controllers which automatically, quickly and with the help of a liquid, supply a temperature. Due to the high reliability and exceptional homogeneity in the measuring chamber, calibration baths are particularly suitable as a factory/working standard for the automatic testing and/or calibration of the widest range of temperature probes - independent of diameter. A special micro calibration bath design enables on-site applications.
-
product
Ultra High 1.77 (50.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-25B-10
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Relative Humidity Kelvin Probe
RHC
The Relative Humidity Kelvin Probe (RHC) systems are the ideal solution for monitoring samples in a controlled atmosphere for contact potential difference (CPD)/work function (Φ) measurements.
-
product
Probes
Fujian Lilliput Optoelectronics Technology Co., Ltd.
We are one of the leading and professional probes manufacturers and suppliers in China. Thanks to our highly qualified experts and advanced technology, we are also one of the world's leading brands. Welcome to buy the quality, cheap and durable probes in stock from us. Check the quotation with us now.
-
product
Structure-Borne Sound Probe
T10
The T10 structure-borne sound probe can be used to monitor the condition of machines, systems and processes, provided that they generate detectable structure-borne sound in the ultrasonic range. Changes in the sound signals indicate a change in the condition and/or process of the plant. The detection of these changes forms the basis for condition monitoring in preventive maintenance. The T10 structure-borne sound probe is used when the installation space is very limited or the test specimen must not be loaded with a large sensor mass. The T10 structure-borne sound probe is also suitable for use on non-magnetic surfaces.
-
product
÷10 HiZ 500 MHz Passive Probe for WaveSufer 400 Series Oscilloscopes.
PP007-WS-1
The PP007 embodies leading technology in passive probe design. The small probe is optimized for maximum waveform fidelity, including high frequency signal components, in a rugged probe suitable for every day.The sharp probe tip* is spring loaded, allowing it to retract into the narrow probe head. The tip does not slip off the object being probed—important when probing small geometry surface-mounted components. Probing dense circuits is easier with the small 2.5 mm ground sleeve, which provides much better visibility than 5 mm and 3.5 mm probes.
-
product
10:1 500 MHz 10 MOhms Passive Probe
PP005A
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MO. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.