Electro-Chemical
chemical action when combined with electricity.
-
Product
30μm Silicon Interdigitated Electrode (IDE)
SBE1
-
30 μm silicon interdigitated electrode (IDE) for MEMS, gas sensing, biosensing, and electrochemical applications. High-precision microfabrication with customizable sizes and electrode configurations for research and OEM projects.
-
Product
Linear Polarization Resistance (LPR) Monitoring
-
The electrochemical technique, commonly referred to as Linear Polarization Resistance, is the only corrosion monitoring method that allows corrosion rates to be measured directly, in real time. Although limited to electrolytically conducting liquids, the response time and data quality of this technique make it clearly superior, where applicable, to all other forms of corrosion monitoring.
-
Product
IDA Electrodes
-
Interdigitated Array (IDA) electrode is an electrode developed for electrochemical measurements to be performed in a very small quantity of the sample. IDA electrode could be applied for the detection and reaction analysis of the compounds in a small quantity of the sample. IDA electrode is a microelectrode pattern fabricated by using the lithography technology. The Electrodes are composed of 65 pairs. In each one of the pair has a function of the oxidation and reduction electrodes.
-
Product
Constant Temperature Humidity Battery Test Chamber
-
Guangdong Test EQ Equipment co., Ltd.
- Battery-Specific Thermal Management: Dual-compressor cascade cooling (-40°C stability) and ceramic heaters for rapid high-temperature recovery.- Precision Electrochemical Control: Integrated battery cyclers with CAN/Modbus protocols, supporting SOP (State of Power), SOH (State of Health), and DCR (Direct Current Resistance) monitoring.- Safety-Centric Design-meet Hazard Level: Chambers are designed with Fire-resistant stainless steel interior, fire suppression,nitrogen purge system, and emergency power cutoff for thermal runaway prevention .- Data Acquisition & AI Analytics: Real-time logging of voltage, current, temperature, and pressure via LabVIEW/Python APIs. AI-driven anomaly detection reduces test cycles by 30%.- Energy Efficiency and Energy Storage: Heat recovery during discharge cycles cuts energy use by 25% (ISO 50001 compliant).
-
Product
S Sensor
Z-Gard S Sensor
-
The Z-Gard S Sensor is designed to detect the presence of carbon monoxide, nitrogen dioxide and combustible gases in air. These sensors employ solid state, electrochemical or catalytic sensors which generate a representative output signal proportional to the calibrated operating range.
-
Product
Oxygen Sensors for Medical Products
-
USA manufactured electrochemical galvanic oxygen sensors (O2 sensors) for use in ventilators, anaesthesia machines, incubators, oxygen monitors and breathing gas mixes.Approved FDA, MDSAP, ISO13485, ISO9001 replacement oxygen sensors for respiratory medical devices with lifetimes up to 60 months. .
-
Product
Graphite Sheet Electrodes
OT1-2
-
High-purity graphite sheet electrodes for electrochemical research, current collectors, electrocatalysis and corrosion testing. Custom sheet dimensions, exposed areas, mounting holes and lead-connection options are available for laboratory cell designs.
-
Product
Cell Stand
CS-3A
-
The CS-3A Cell Stand is adopted with CHI series Electrochemical Analyzers and other apparatus directly. The cell is enclosed in a Faraday cage to reduce electrical interference. A built-in gas control allows purging a sample. Gas line is provided to purge next sample, while analyzing the present sample separately, thus increasing productivity. Magnetic stirrer allows for controlling the mixing of the sample for experiments requiring mass transport of electrolyte or analyte to the electrode surface. Cell top positioner with detachable cell cap allows easy removal and replacement of the cell vial as well as the electrodes for rinsing, cleaning, and replacement.
-
Product
Scanning Probe Workstations
-
BioLogic has over 25 years of experience producing scanning probe electrochemistry instruments. Initially this included a number of single technique instruments, with the first modular scanning electrochemical workstation, the M370, introduced in 2006, under the Uniscan name.Scanning probe electrochemistry has found use in academic and commercial research settings. It is applicable in any field in which bulk electrochemical measurements have been used. Scanning probe electrochemistry has found widespread use in: Corrosion and coatings, Biology, including biosensors and biotechnology, Batteries, fuel cells and photovoltaics, Materials, Catalysis
-
Product
Screen-Printed Electrodes
-
Screen-printed electrodes (SPEs) for electrochemical sensing, biosensor development and routine analytical testing. PotentioLab supplies disposable carbon, gold, platinum and modified SPE formats for laboratory research, portable electrochemical systems and method development.
-
Product
CO/Co2 Testers
-
TES Electrical Electronic Corp.
CO-0-999 pp, range. Max hold with time stamp.Alarm level setting. Replaceable sensor extends meter life.Stabilized electrochemical CO Sensor.Automatic sensor zeroing upon start-up.
-
Product
Water Quality Products
-
When you need to perform critical water testing, look to us for an extensive selection of electrochemical meters, controllers, probes, electrodes, test kits, buffers, and standards. Our field and laboratory instrumentation include water analysis instruments for dissolved oxygen, temperature, pH, conductivity, salinity, and turbidity.
-
Product
Tribocorrosion Tester
ASTM G119
-
Tribocorrosion involves studying Wear Evaluation of Protective Coatings. It involves mechanical and electrochemical interactions between components in motion. Rtec Tribocorrosion modules measures inline current, voltage, friction, wear, temperature , down force, ear, acoustic emissions at all times. Currently used by several Fortune 500 firms globally.
-
Product
Three-Neck H-Type Electrochemical Cell
CTH-1
-
CTH-1 three-neck H-type electrochemical cell designed for electrocatalysis, electrochemical analysis, and laboratory three-electrode systems. Available in 30ml to 250ml capacities with dual-chamber glass structure and excellent chemical resistance.
-
Product
Screen-Printed Carbon Electrode With Ag/AgCl Reference (RE)
SPE01
-
A screen-printed silver (Ag) reference electrode designed for electrochemical sensing, biosensor development, environmental monitoring, and laboratory research with excellent reproducibility and customizable electrode configurations.
-
Product
T-Type Platinum Sheet Electrode Clip
TTP-1
-
TTP-1 T-Type Platinum Sheet Electrode Clip is an electrode holder, clip or electrochemical cell accessory designed to position electrodes securely and provide stable electrical connection during laboratory electrochemical testing.
-
Product
Time-Resolved Electrochemical Quartz Crystal Microbalance
400C Series
-
The quartz crystal microbalance (QCM) is a variant of acoustic wave microsensors that are capable of ultrasensitive mass measurements. Under favorable conditions, a typical QCM can measure a mass change of 0.1-1 ng/cm2. QCM oscillates in a mechanically resonant shear mode under the influence of a high frequency AC electric field which is applied across the thickness of the crystal. Figure 1b below shows an edge view of a QCM crystal undergoing oscillatory shear distortion. The central portions of the top and bottom of the crystal are coated with a typically disk-shaped thin metal film (e.g., gold).
-
Product
Crocodile Clip Simple Electrode Holder
CCS-1
-
CCS-1 compact electrode holder with a PTFE sleeve and stainless-steel or copper crocodile clip, providing stable electrical contact for electrochemical experiments.
-
Product
Universal Electrode Holder Series
PSE-1
-
The PSE-1 Universal Electrode Holder Series is designed for secure mounting of platinum, gold, titanium, copper, stainless steel, graphite, and glassy carbon electrodes in electrochemical experiments. Available in PTFE and PEEK body options, with standard, extended, L-type, rod, and custom configurations to accommodate a wide range of cell designs and laboratory setups.
-
Product
Unsealed Jacketed Electrochemical Cell – Temperature-Controlled
DL-1
-
DL-1 Unsealed Jacketed Electrochemical Cell – Temperature-Controlled is an electrochemical cell for laboratory research, designed for three-electrode testing, sealed or unsealed experiments, photocatalysis, corrosion studies, optical observation, or customized electrochemical workflows depending on the selected model. The cell can be matched with working electrodes, reference electrodes, counter electrodes, gas ports, quartz windows, PTFE covers, jackets, and custom fittings according to the experimental setup. Please confirm the required volume, sealing method, electrode ports, and application conditions before ordering.
-
Product
Alcohol Tester
-
Shenzhen Graigar Technology Co.,Ltd.
Electrochemical (fuel cell) alcohol sensor, Module changeable Test Range: 0.000-2.000mg/l (0.400%B.A.C; 4.000%oB.A.C; 4.000g/l;) Alarming level: Pass level: 0.090mg/L (could be modified) Fail level:0.250mg/L (could be modified) Accuracy: +/-10% Work temperature: -10oC-50oC Work humidity: <95%RH (No Dews) Battery: 2XAA NiMH batteries, rating capacity: 2.1AH Dimension lXbXh: (mm) 250X105X400 Indication manner: mg/l,mg/100ml,g/l ,%BAC,%oBAC optional Coin for single time: 0-15 (For 0, the tester can be tested without coin). Coin diameter: 20mm-28mm Coin thickness: 1.2mm-2.5mm Coins Capacity: about 200 pieces Straw capacity: 200pcs(⊄<=7mm) Breath sampling time: about 5 seconds continuous breath.
-
Product
Multichannel Potentiostats
-
Multi Channel potentiostats/galvanostats from Princeton Applied Research and Solartron Analytical assist researchers increase their scope from the examination of a single sample at a time to multiple samples simultaneously. While providing the same level of accuracy as the single channel potentiostats, multi channel potentiostats can be configured to scale with your research today as well as provide solutions for the next step in your electrochemical research plan tomorrow.
-
Product
Screen-Printed Gold Electrode For Electrochemical Sensing
GPE1
-
A gold screen-printed electrode (SPE) designed for electrochemical sensing, biosensor development, molecular detection, and laboratory research with excellent reproducibility and customizable electrode configurations.
-
Product
EIS Battery Analyzer
BA8100
-
The BA8100 is designed to accurately measure the internal impedance of a single cell or battery stack with voltages as high as 80 V. In addition to impedance, auxiliary measurements include voltage, current, phase, capacitance, inductance, quality factor and more. With the provided software, the BA8100 can perform Electrochemical Impedance Spectroscopy (EIS) across a frequency range of 50 mHz to 10 kHz. The impedance spectrum can be evaluated through the Nyquist and Bode plot tools to determine effective series resistance (ESR) and track battery health. Included with the BA8100 is a self-test fixture to verify the instrument’s performance or compensate for resistance introduced by the test leads.
-
Product
Metal Sheet Working Electrodes
CS1
-
Metal sheet electrodes for electrochemical research, corrosion testing, and materials evaluation. Available in iron, copper, nickel, titanium, stainless steel, aluminum, zinc, silver, gold, platinum, tungsten, graphite, nickel foam, and MMO-coated titanium materials. Standard dimensions are available, with custom sizes and materials supported upon request.
-
Product
Acrylic Electrolytic Cell
CAE-1
-
Custom acrylic electrolytic cell for electrochemical testing, electrolysis, and electrodeposition. Transparent PMMA body with customizable ports and dimensions.
-
Product
Solid State Battery Molds
-
Solid-state battery molds for laboratory pressing, assembly, and testing, designed for reliable cell fabrication under controlled pressure conditions. Suitable for solid-state battery research, material evaluation, and electrochemical testing.
-
Product
L-Type Multi-Purpose Platinum Sheet Electrode Clip
EH-1
-
EH-1 L-Type Multi-Purpose Platinum Sheet Electrode Clip is an electrode holder, clip or electrochemical cell accessory designed to position electrodes securely and provide stable electrical connection during laboratory electrochemical testing.
-
Product
U-Type Glassy Carbon Electrode | 3mm
CS1-1
-
U-Type Glassy Carbon Electrode with PTFE insulation for electrochemical applications. Suitable for CV, EIS, electrocatalysis, corrosion testing, and electrochemical sensor research. Available in standard and custom configurations.
-
Product
CR2032 Coin Cell Compression Mold
CCC1
-
CR2032 coin cell compression mold designed for solid-state battery pressure testing and electrochemical research.





























