Line Impedance Stabilization Network
Line Impedance Stabilization Network
See Also: Line Impedance, LISN
-
product
Line Injector
J2120A
While the injection transformer is a very wideband adapter, it is not useful for measuring ripple rejection (PSRR) of a power supply or even an opamp. This is because the attributes that make the injection transformer perform so well also result in a transformer that is intolerant of DC current. Even very small DC currents (5mA or less) can greatly reduce the signal capacity or even totally saturate the transformer. For this reason, the Picotest line injector (J2120A) is another essential test adapter.
-
product
PNA Microwave Network Analyzer
N5227B
Meet your toughest measurement challenges with the highest performing microwave network analyzer in the industry Measure S-parameters with the smallest uncertainty and highest stability Efficiently characterize active components with applications that simplify setups Meet your specific budget and measurement needs by customizing to just the right level of performance Accelerate insight into component behavior using a multi-touch display and intuitive user interface Every spec verified, adjustments included Lock in support & peak performance from the start
-
product
Turret Drive Stabilization System
Curtiss-Wright Defense Solutions
Weapons' accuracy and reliability are crucial factors for combat success. The ability to accurately locate a target and stabilize the shot while moving out of the line of sight could make all the difference.
-
product
Temperature Stabilized Antenna
TSA-100
A major source of error in timeand frequency receivers is the variationof signal delay due to changes in the outdoor temperature. The designofthe TSA-100 includes two fully independent thermal zones, each with itsown precision heating and cooling capability. The result is that thetemperatureof the preamp is maintained within ±0.5°C over an ambient temperaturerange of -20°C to +50°C. This system virtually eliminates bothseasonal and diurnal variations, supporting exceptionalrepeatability.
-
product
Network Analyzer N-Port Calibrated Measurements
S95551B
PXI vector network analyzers (VNA) offer the capability to extend the number of ports for your measurements by using additional modules. When multiple modules are used, they are configured for multiport operation. The S95551B adds a multiport analyzer mode that enables full multiport error correction and measurement capabilities. The instruments may be identified as one VNA by the firmware running on an external host PC. At least one VNA instrument connected to your PC must have one S95551B license to maintain N-port capabilities.
-
product
High Impedance Probes
Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.Everbeing offers GGB’s high impedance active probe for failure analysis of your devices. The high impedance with low capacitive design allows measurements of internal nodes without loading the device. For more information, please visit http://www.ggb.com.
-
product
Stability Chambers
PH Series
The Darwin Chambers PH Series Stability Chambers are designed for performance specifications exceeding FDA and ICH requirements. For GMP studies, ultrasonic humidification provides excellent humidity control and avoids hot spots during mapping. Thermoelectric cooling provides more stable temperature control than equivalent refrigeration systems. All PH series chambers incorporate inherent cooling redundancy, quiet operation, simple serviceability and excellent reliability.
-
product
Bench-top Stabilized Laser Source
JW8002
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
JW8002 Bench-top stabilized laser source is a new instrument with high output stability and good wavelength stability, which is developed byJoinwit Company using automatic optical power control (APC) technology and automatic temperature control (ATC) technology. JW8002 is an ideal instrument for measuring optical device characteristics, device aging, monitoring, experiment, etc. JW8002 is simple in application and design, easy to use and maintain. Widely used in optical communication, optical transmission, optical fiber sensing and other fields of scientific research, production and engineering.
-
product
Impedance Analyzer
MFIA
The Zurich Instruments MFIA is a digital impedance analyzer and precision LCR meter that sets the new standard for impedance measurements in the frequency range from DC to 5 MHz. The MFIA provides 0.05% basic accuracy and a measurement range spanning from 1 m to 10 G. The instrument has a high measurement repeatability and a small temperature drift. With the LabOne user interface the MFIA offers a number of long-awaited innovations for the impedance and LCR measurement available without the need of any software installation.
-
product
Stability Chambers
Our stability test chambers are ideal for pharmaceutical, packaging, life science, personal care, medical, biomedical storage, research, and more.
-
product
Venable Stability Analysis Software
In 1983, Venable launched the renowned K-Factor Technique, still in use by many instrument manufacturers today. Venable has elevated the original software with its innovative Stability Analysis program. Go straight from measurement to design using Stability Analysis as its dynamic functionality eliminates lengthy manual value calculations and guesswork. Compensation amplifier synthesis capability, or coefficients for digital power supplies, enables user to achieve exact feedback loop bandwidth and phase margin desired on the first try.
-
product
Impedance meters
Electronic components meters for circuit verification in laboratories, technical schools and technical support centres.
-
product
Oxidation Stability Testers
Automatic lubricating oils oxidation stability tester, transformer oil oxidation stability tester, distillate fuel oil oxidation stability tester, gasoline oxidation stability tester (induction period method)
-
product
Battery Impedance Tester
KVBT-15S
KV Hipot Power Test Equipment Co.,Ltd
Battery Internal Resistance Tester with advanced AC discharge measurement method, is applied to test accurately the voltage and resistance of battery capacity and state.
-
product
Streamline Vector Network Analyzer, 9 KHz To 4.5 GHz, 4 Or 6-port
P5020B
Compact, faceless, vector network analyzer (VNA). Flexible four or six-port VNA dramatically reduces your size of test. Up to 4.5 GHz.
-
product
Impedance Matching Pads
Surface mount and coaxial 50 Ohm / 75 Ohm impedance matching pads for CATV systems, broadband networks, test setups and more!
-
product
Antenna Impedance Converter
The low noise impedance matching equipment has a high impedance input with minimized capacity. With the 50 Ω output it can be used with common EMI receivers or spectrum analyzers to measure the emissions received by an antenna on a vehicle.
-
product
PXIe Vector Network Analyzer Source, 1 MHz To 6 GHz
M9389A
The M9389A PXIe vector network analyzer source is a component for the M9485A PXIe multiport vector network analyzer. The M9389A configuration includes two PXIe modules (M9310A source output, M9309A synthesizer) and its control is provided through the M9385A software front panel (SFP). The M9485A provides a true multiport VNA with up to 12-ports in one chassis and up to 24 ports in two chassis.
-
product
Impedance Analyzer 1MHz-20Hz
IA1000
Frequency range20 ~ 1MHzFrequency accuracy0.005%Frequency resolution0.001% in all frequency rangeTest signal level0.05 ~ 2.0 VrmsTest signal resolution0.001 VrmsTest signal output impedance100ΩImpedance Z range; basic accuracy0.0000Ω ~ 99.99
-
product
FDA/ICH Stability Rooms
Darwin Chambers Company Stability Rooms offer superior environmental control for a wide variety of products needing a specific temperature and/or humidity conditions, Darwin Chambers is proven to exceed ICH/FDA stability requirements. For this reason, our FDA/ICH chambers are highly sought. Pharmaceutical shelf-life testing, accelerated stability studies, and testing and storage for cosmetics, animal health products, nutritional supplements, general products, medical devices, packaging materials are just a few applications we service.
-
product
Ultra-High Stability DC Power Supply
62075H-30N
The 62075H-30N output power has maximum 7.5kW/30V/250A power module designed with 4U height that can be connected easily as master or slave with three units to 22.5kW/30V/750A in parallel or two units to 15kW/60V/250A in series and operated as a standalone unit via system bus. The 62075H-30N provides stable DC output cur rent sour ce and powe r for pre c i s ion measurement. It offers an advanced 250A/30V ultra high-stable ±10 ppm (current stability ±1.25 mA) with high eciency and high power factor in compliance with energy savings. In addition it has a 20 bit digital control with bright vacuum fluorescent display readout.
-
product
Electrical Impedance Tomography
Electrical Impedance Tomography (EIT) is an imaging technique that visualizes conductivity or impedance distributions both in 2D and in 3D. Sciospec is partnering with world leading scientists in the field to deliver solutions that enable using EIT both in research and in practical applications.
-
product
Aluminum Cabinet Stabilizers, Pair
ST-1
Cabinet stabilizers are cast aluminum construction. They extend 10” (254mm) from the base and are adjustable with leveling screw/pads.
-
product
Transmission Line Probes
Transmission line probes are a special type of passive probe designed for use at very high frequencies. They replace the high impedance probe cable found in a traditional passive probe with a precision transmission line, with a characteristic impedance that matches the oscilloscope input (50 Ohm). This greatly reduces the input capacitance to a fraction of a picofarad, minimizing the loading of high frequency signals. A matching network at the tip increases the DC input resistance. While they have lower DC input resistance than a traditional passive probe (usually 500 Ohm) to 1kOhm), the input impedance of these probes remains nearly constant over their entire frequency range. A traditional /10 passive probe will have a 10 MOhm) input impedance at DC, however this impedance drops rapidly with frequency, passing below the input impedance of a transmission line probe at less than 100 MHz.
-
product
Focus Control And Stabilization
Applied Scientific Instrumentation
The CRISP system is designed to maintain focus over time i.e. compensate for thermal & other factors that may cause the sample to drift out of focus over time. It also can be used to maintain a given focal point while scanning the sample in XY. If you are looking to find the optimal focal point while scanning through the sample in Z phase.
-
product
RADAR Stability Testing
PN9002
Radar component and system testing usually evokes images of complex, expensive measurement systems occupying multiple equipment racks. In some cases, radar equipment designers have even used entire radar systems as a proving ground for their new components and modules. With the introduction of the PN9002 pulse-to-pulse radar stability test set from Noise eXtended Technologies , radar testing has become significantly less complex and costly. The modular PN9002 system provides outstanding dynamic range at frequencies from 2 to 18 GHz and optionally from 0.4 to 18 GHz.
-
product
Streamline USB Vector Network Analyzer, 4.5 GHz
P5000A
Compact, faceless, USB vector network analyzer (VNA). Flexible two-port VNA which dramatically reduces your size of test. Up to 4.5 GHz.
-
product
Impedance Analyzer 10MHz-20Hz
IA1021
Feature Specifications: Dual test mode: Analyzer(frequency sweep) and LCR(single frequency).Measurement frequency: 20Hz to 10MHz, 6 digitsFrequency resolution: 0.001% in all frequency rangeFrequency accuracy: 0.01%.DC bias(program): -10V ~ +10V, 0.005V resolution, accuracy 0.5%.Measurement basic accuracy: Impedance +-0.2%, phase: +-0.1°.Display Range: Z: 0.0000Ω-99.999MΩ.





























