ICP
-
Product
PROBE MICROPHONE ICP
377B26
-
Open Circuit Sensitivity (at 250 Hz)Frequency Range (+2.2/-4.9 dB)2 to 20000 HzLower Limiting Frequency (-3 dB)Inherent Noise<45 dB(A) re 20 Pa Dynamic Range(3% Distortion Limit)EnvironmentalTemperature Range (Operating)-40 to +158 F-40 to +70 C[5]
-
Product
ICP Plasma System
-
The AXIC IsoLok® Inductively Coupled Plasma (ICP) Load-Locked Processing System from AXIC, Inc. defines a new concept in Deep Reactive Ion Etch (DRIE) and low temperature-low damage Plasma Enhanced Chemical Vapor Deposition (ICP-PECVD) plasma processing. The system is based on a modular design starting with a universal chamber and cabinet unit with ICP etch or deposition bottom electrodes available for easy installation into the chamber unit combined with a load-lock. We are confident you will find the ease of use, variety of plasma processes, serviceability and attractive pricing unsurpassed by any other plasma product in the market.
-
Product
In-line ICP® Charge Converters
-
In-line ICP® charge converters play a vital role in converting high impedance charge mode piezoelectric sensor signals into low impedance voltage signals, facilitating input to readout, recording, and analysis instruments. Specifically engineered for compatibility with high temperature piezoelectric sensors, these units are capable of operation in environments reaching up to 500°F (260°C). The series boasts ±2.5V or ±5.0 V output, offering a range of gain options, all packaged within a compact and durable casing. As a cost-effective alternative to laboratory charge amplifiers, in-line ICP® charge converters present an appealing choice for multi-channel applications.
-
Product
Low Outgassing ICP® Accelerometers
-
Low Outgassing ICP® (IEPE) Accelerometer Types & Their Applications.
-
Product
Structural Test ICP® Accelerometers
-
Conventional structural test data systems use few to several hundred sensors. Cables bundles can be complex and confusing resulting in setup errors. Sensors with TEDS (Transducer Electronic Data Sheet) allow for an internal sensor digital chip to store sensor information. This information contains descriptive identifiers that when connected to a TEDS compatible signal conditioner or data system, reads the descriptive information and automatically aligns the data system. Human error is minimized, reducing time consuming data verification or re-test. The Series 333 ICP® accelerometers, and their accessories, are designed to address the needs of multi-point modal and structural test measurement applications. This equipment was developed in conjunction with the world renowned University of Cincinnati Structural Dynamics Research Laboratory and proven in real-world testing situations. The PCB 333 Series accelerometers delivers rapid system setup, reduces human documentation errors, maintains calibration data of each sensor, allows for “Plug-and-Play” installation, reduces overall test time lowering project test costs.
-
Product
On-line ICP / ICP-MS Sample Preparation System
SDX ʜᴘʟᴅ
-
The SDXHPLD system combines the proven ASX‑560 autosampler with a novel vortex mixing dilution accessory. The system dilutes in the same way you do by hand: volume-to-volume dilution, using a highly accurate syringe pump. But it also goes an additional step to vortex mix the resulting dilution prior to sample introduction to ICP and ICP-MS.The SDX employs vortex mixing to promote homogenization of a sample to ensure accurate and precise analysis following dilution. The variety of sample matrices submitted for trace element analysis necessitates the need for mixing. This long overdue capability improves data quality by fully homogenizing a dilution mixture rather than performing in-line combination.The SDXHPLD is a straight-forward, fully-integrated solution for automated dilution of aqueous and acid base sample prep for ICP or ICP-MS.
-
Product
ICP OES spectrometer (ICP AES)
-
SPECTRO Analytical Instruments GmbH
ICP OES spectrometer (ICP AES) for the rapid analysis of elements in a variety of matrices including aqueous, semi-conductor, petrochemical, soil, metallurgical and slurries
-
Product
Sub-Miniature ICP® Pressure Sensors
-
PCB's sub-miniature 105C dynamic pressure sensors are specifically designed to fit into tight spaces where mounting space is at a premium.
-
Product
ICP Microphone System
378C01
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration. Click the following for individual component information.
-
Product
Quartz ICP® Force Rings
-
Ring-style sensor configurations measure dynamic compression. Tension measurements are also possible if the unit has been installed with proper pre-load. The through-hole mounting supports platform, integrated link, and support style installations using either a through-bolt or the supplied stud.
-
Product
High Sensitivity ICP® Accelerometers
-
High sensitivity ICP® accelerometers are specifically designed to enable the detection of ultra-low-level, low-frequency vibrations associated with very large structures, foundations, and earth tremors. These sensors typically possess exceptional measurement resolution as the result of its comparatively larger size, which furnishes a stronger output signal and a lower noise floor. All units are hermetically sealed in a titanium or stainless steel housing. Models that include a 2-pin, military style connector provide the added benefit of being electrically case isolated for superior RF and EMI protection.
-
Product
ICP Electret Array Microphone
130A23
-
Nominal Microphone Diameter: 1/4" Frequency Response Characteristic (at 0 incidence)Free-FieldInherent Noise (A Weighted)<30 dB(A) re 20 Pa<30 dB(A) re 20 Pa Dynamic Range (High)150Environmental Temperature Range ( Temperature Effect on Output (-10 to +50 C)<0.7 dB<0.7 dB[2] Influence of Axial Vibration Excitation Voltage 18 to 30 VDC18 to 30 VDC
-
Product
Industrial ICP® Strain Sensors
-
For Process Monitoring/Quality Control. The Industrial ICP® Strain Sensors incorporate piezoelectric quartz sensing crystals that respond to a longitudinal change in distance. The resultant strain measurand is an indirect measurement of stress forces acting along the structure to which the sensor is mounted. As such, these devices can provide insight into the behavior of mechanical systems or processes that generate an associated machinery reaction.
-
Product
ICP Microphone System
378A14
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
Compressor-Cooled Incubator
ICP
-
Our ICP compressor-cooled incubator offers great results whenever a rapid and precise changeover between heating and cooling phases in ramp operation is required. Due to the finely tuned control technology, temperatures exactly reach the setpoint values without the need for energy-intensive bursts of power.
-
Product
Reusable ICP® Strain Gauge
-
This high-resolution dynamic alternative to bond foil strain gauges uses a quartz sensing element in a durable, titanium housing. It has 0.0006 microstrain resolution, 5 volt output, 100k Hz frequency response and 0.5 gram mass for lightweight test articles. The reusable sensor comes with a calibration certificate, attaches to the test specimen in 60 seconds and is removed in 10 seconds.
-
Product
Dual Matrix Autosampler
Oils 7400
-
Oils testing laboratories are adding more sample types as their industry becomes more complex. The Oils 7400 Homogenizing Autosampler allows two sample matricies to be introduced to an ICP instrument from the same system. Boasting a dual port rinse station fed by two separate peristaltic pumps, it can change between oils and coolants testing on demand. With improved speed, mixing capability and sample drip capture, the Oils 7400 delivers robust analysis without compromise.
-
Product
Vibration Transducers Calibration System
-
The system is used for calibration of vibration transducers as well as:*ICP and charge accelerometers;*piezoelectrical and capacitive vibration transducers;*vibration-measuring instruments.
-
Product
Inductively Coupled Plasma Spectroscopy (ICP-OES/MS), ICP Analysis Services
-
ICP-OES measures the light emitted at element-specific characteristic wavelengths from thermally excited analyte ions . This light emitted is separated and measured in a spectrometer, yielding an intensity measurement that can be converted to an elemental concentration by comparison with calibration standards. ICP-MS (ICP-Mass Spec) measures the masses of the element ions generated by the high temperature argon plasma. The ions created in the plasma are separated by their mass to charge ratios, enabling the identifcation and quantitation of unknown materials. ICP-MS offers extremely high sensitivity (i.e. low detection limits) for a wide range of elements
-
Product
General Purpose Coaxial Cables For Sensors
-
General purpose coaxial cables are used with single axis ICP® sensors. This table provides relevant specifications for four cable types. Type 002 is the most commonly used, but three other types are also available.
-
Product
4-conductor Cables For Sensors
-
4-conductor cables are used with ICP® triaxial sensors and single axis MEMS sensors. This table provides the most relevant specifications for five cable types. Type 010 and 034 are the most commonly used, but three other types are also available.
-
Product
Dual-Mode Charge Amplifiers
-
Dual-mode charge amplifiers represent a versatile solution for both piezoelectric charge mode and ICP® sensors. Among the advanced features offered by models 443B01, 443B02 and 2775C are an ultra-low noise floor, sensor fault detection, overload detection, a built-in calibration reference signal, and an RS-232 port for seamless computer control. Notably, model 443B02 features a long discharge time constant selection, ideal for capturing quasi-static events lasting several seconds, a capability particularly beneficial for ballistics and ammunition testing applications. Model 2775C features AC, DC, and servo outputs.
-
Product
IEPE Triaxial Accelerometer – 1000 mV/g
HDP356B18
-
Triaxial accelerometer high sensitivity, ICP, 1V/g, weight 25g, range 5 g pk
-
Product
Chemical Testing
-
Accolade Engineering Solutions
To ensure product environmental compliance or to gain better understanding of your materials or processes, chemical testing is often required. AES has state of the art the equipment for chemical analysis. For elemental analysis XRF, SEM/EDS or ICP can be used. For molecular analysis GCMS, HPLC and FTIR may be used. FTIR may also be used for surface analysis of contamination and our microFTIR system is suitable for the smallest samples.
-
Product
ICP Microphone System
378C10
-
This model includes a 1/4" microphone cartridge, a mated preamplifier with TEDS, and system calibration.
-
Product
Cryogenic ICP® Accelerometers
-
Cryogenic ICP® accelerometers are specifically designed to operate at temperatures below the typical -65 ºF (-54 ºC) temperature limit of most voltage mode sensors. The use of specialized, built-in, cryogenic circuitry and quartz shear sensing technology promote survivability in demanding environments such as liquid nitrogen. Each sensor is hermetically sealed and individually tested to determine the thermal coefficient of sensitivity at -320 ºF (-196 ºC) ensuring reliable operation and accurate measurements. These sensors have been successfully used in the presence of liquid helium during structural testing of rocket boosters.
-
Product
ICP-MS spectrometers (ICP MASS)
-
SPECTRO Analytical Instruments GmbH
SPECTRO MS is a double-focusing sector field ICP MS (ICP mass spectrometer) based on a Mattauch-Herzog geometry with a newly developed ion optic and pioneering detector technology. It is the only ICP MS instrument available on the market today that is capable of simultaneously measuring the complete mass range used for inorganic mass spectrometry from 6Li to 238U with a permanent ion beam going to the detector.
-
Product
PCB High Sensitivity, 100mV/g, ICP® (IEPE) Accelerometer
784170-01
-
The PCB HSTA15 helps you acquire sound and movement data with supported PXI Sound and Vibration Modules, C Series Sound and Vibration Input Modules, and USB-based Sound and Vibration Devices. This sensor uses the Integrated Electronics Piezo-Electric (IEPE) current excitation. The PCB HSTA15 features a sensitivity range of 10 mV/g and requires a 4-socket plug-to-3 BNC plug cable.
-
Product
Autosampler
ASX‑560
-
Users call CETAC Autosamplers the best on the market, and it’s easy to see why. Put the most reliable, efficient and solidly built autosampler to work in your lab for sample analyses. We have a model to meet your needs, regardless the size of your lab or your specific technique, whether AA, ICP, ICP-MS, TOC, US-VIS, flash/prep chromatography, protein purification, liquid handling or others.
-
Product
IEPE Monoaxial Accelerometer – 100 mV/g
HDP352C34
-
Monoaxial accelerometer general purpose, ICP, 100mV/g, weight 5,8 g, range 50 g pk