Dense Wavelength Division Multiplexing
Dense Wavelength Division Multiplexing
-
Product
PXI 2 Amp MUX, Single 64-Channel 1-Pole
40-635-001
Multiplexer Module
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI 2A Multiplexer, 16-Bank, 8-Channel 1-Pole
40-614-001
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
PXI 2 Amp MUX, Single 4-Channel 8-Pole
40-635-104
Multiplexer Module
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI/PXIe High Voltage Multiplexer, Triple 7-Channel, 2-Pole
40-321-122-HI
Multiplexer Module
The 40-321-122-HI (PXI) and 42-321-122-HI (PXIe) are triple 7-channel 2-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
Wavelength Meter
-
HighFinesse/Ångstrom offers sensitive and compact wavelength meters with a large spectral range for high speed measurement of lasers. The optical unit consists of temperature-controlled Fizeau-based interferometers that are read out by photodiode arrays. The high absolute accuracy is achieved by use of solid state, non-moving optics.
-
Product
PXI 8-slot BRIC Power Multiplexer, 5-Channel, 48-Pole (7 Sub-cards)
40-571A-005
Multiplexer Module
The 40-571A-005 is a 5-channel, 48-pole 3 Amp Power Multiplexer and is part of our BRIC family. The 40-571A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
Product
PXI/PXIe High Density 2A Multiplexer, 1-Bank, 4-Channel, 32-Pole
42-614D-020
Multiplexer Module
The 40-614D-020 (PXI) and 42-614D-020 (PXIe) 1-bank, 4-channel, 32-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI 2 Amp MUX, Quad 4-Channel 2-Pole
40-635-109
Multiplexer Module
The 40-635 2 Amp Multiplexer module is available in 9 standard configurations as well as 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP10T, 18 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
40-788-121-TE
Multiplexer Module
The 40-788-121-TE (PXI) and 42-788-121-TE (PXIe) are single failsafe SP10T 18 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
PXI 2A Multiplexer, 4-Bank, 4-Channel 8-Pole
40-614-009
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
PXI/PXIe RF Multiplexer, Single 16-Channel, Terminated, 8GHz, 50Ω, SMA
40-883B-002
Multiplexer Module
The 40-883B-002 (PXI) and 42-883B-002 (PXIe) are single 16 to 1 50Ω RF multiplexers with 8GHz bandwidth and automatic termination of unused signal channels. They are available in 8 to 1 and 16 to 1 configurations in two and three slots respectively.
-
Product
PXI/PXIe MEMS Optical Switch, Dual Insert/Bypass
40-860A-322
Multiplexer Module
The 40/42-860A-322 is a PXI/PXIe dual insert/bypass switch with MU connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
Product
PXI Solid State Multiplexer, Dual 3-Channel, 30 Amp
40-667B-011
Multiplexer Module
The 40-667B-011 is a dual 3-channel 30A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
Product
PXI 5A Mux 1-Bank 48-Ch Isolated COM
40-651-011
Multiplexer Module
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel. Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP10T, 22 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-788-131-E
Multiplexer Module
The 40-788-131-E (PXI) and 42-788-131-E (PXIe) are single failsafe SP10T 22 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP6T, 26.5 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-785C-531-TE
Multiplexer Module
The 40-785C-531-TE (PXI) and 42-785C-531-TE (PXIe) are single failsafe SP6T 26.5 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI Dual 3-Channel 30A Solid State MUX
40-667-011
Multiplexer Module
The 40-667 is a high current multiplexer available in dual 3-channel or single 6-channel configurations occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation.Each multiplexer channel can support 30A of continuous current and switch up to 40V signals. The switches can sustain inrush currents in excess of 120A. AC or DC signals can be switched since the switch is polarity insensitive.Note: The 40-666-011 supersedes the 40-666-001 which is functionally the same but with some changes in specification. A data sheet for the 40-666-001 can be found in the 40-666/667 User Manual.
-
Product
16-bank, 4-channel, 2 pole version is part of the 40-614C High Density 2A Multiplexer
40-614C-002
Multiplexer Module
This 16-bank, 4-channel, 2 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 2-Bank 6GHz SMA
60-802-002
Multiplexer Module
The 60-802-002 is a 4-channel, 2-bank RF multiplexer suitable for switching 50Ω signals up to 6GHz. It is part of a range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for between 1 and 16 banks of 4 or 6-channel multiplexers.
-
Product
PXIe Microwave Multiplexer, Single SP6T, 26.5 GHz, 50 Ω, SMA, Terminated, Failsafe
42-785C-531-T
Microwave Multiplexer
The 40-785C-531-T (PXI) and 42-785C-531-T (PXIe) are single failsafe SP6T 26.5 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
LXI Microwave Multiplexer, SP4T, 2-Bank, 50GHz, 50Ω, SMA-2.4
60-803-702
Multiplexer Module
Our 60-803-702 is a 2 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 50GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 2.5 GHz, 75 Ω, 1.6/5.6, Failsafe
42-785C-752
Multiplexer Module
The 40-785C-752 (PXI) and 42-785C-752 (PXIe) are dual failsafe SP6T 2.5 GHz unterminated 75 Ω microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
LXI Microwave Multiplexer, SP4T, 11-Bank, 67GHz, 50Ω, SMA-1.85
60-803-811
Multiplexer Module
Our 60-803-811 is a 11 bank SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 67GHz. The 60-803 range is capable of supporting up to 16 banks of 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
LXI Microwave Multiplexer, 50Ω 6-Channel 8-Bank 40GHz SMA-2.9
60-801-408
Multiplexer Module
The 60-801-408 is a 6-channel, 8-bank RF multiplexer suitable for switching 50Ω signals up to 40GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI/PXIe High Density 2A Multiplexer, 2-Bank, 16-Channel, 4-Pole
42-614D-012
Multiplexer Module
The 40-614D-012 (PXI) and 42-614D-012 (PXIe) 2-bank, 16-channel, 4-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
PXI RF Multiplexer: 3 GHz, Quad 1 x 4, 50 Ω, Terminated Common
M9147A
Multiplexer Module
Route signals up to 3 GHz through any of four 1 x 4 RF switch multiplexers in a single PXI module.
-
Product
8-Ch SPST 12A-250VAC 24VDC Multiplexer with CAN
H620047C2
Multiplexer Module
This module is ideal for switching up to 12A. Composed by eight relays organized in two trees of four with two relays with NC contact available. The module is shielded in order to reduce the radiated interference in high current switchings.
-
Product
PXI Dual SP6T Multiplexer 26.5GHz 50 SMA
40-784A-032
Multiplexer Module
Pickering Interfaces’ range of 40-784A PXI Microwave Multiplexer Modules have a characteristic impedance of 50Ω and are capable of switching signals up to 40GHz. Available in single, dual or triple, SP6T or SP4T formats, they are suitable for constructing complex microwave switching networks and provide a range of switching configurations to suit most applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors
-
Product
PXI/PXIe Microwave Multiplexer, Single SP8T, 8 GHz, 50 Ω, N-Type, Remote Mount, Failsafe
40-788-011-E
Multiplexer Module
The 40-788-011-E (PXI) and 42-788-011-E (PXIe) are single failsafe SP8T 8 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-788 range of multiplexers are also available as single or dual, SP8T, SP10T or SP12T panel mounted multiplexers with relays mounted on the front panel.
-
Product
PXI 3A Power MUX BRIC, 4-Channel, 24-Pole
40-571-102
Multiplexer Module
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.




























