Filter Results By:
Products
Applications
Manufacturers
Gold
invaluable naturally occurring material able to withstand corrosion, highly conductive. AKA: Au
See Also: Precious Metal, Platinum, Au, Gold Test
-
product
Mini Power, Receiver, 50u Gold (22 Amps). 18 AWG Twisted Pair Red/Black (5 Amps). Banana Plug Black, Banana Plug Red, 41"
7-242418000-041
Mini Power, Receiver, 50u Gold (22 Amps). 18 AWG Twisted Pair Red/Black (5 Amps). Banana Plug Black, Banana Plug Red, 41"
-
product
Micro Coax, Contact, ITA, 75 Ohm, RG179
610141103
Primary mating contact 610140103. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 75ΩFrequency Range DC – 2 GHzVSWR 1.39 @ 2 GHzInsertion Loss – √f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG179Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
Gold Probes
4900 Series
The "GOLD PROBE" has been designed specifically for use with Tektronix, Hewlett Packard and other high performance oscilloscopes. This new slim design along with a host of versatile accessories, allows you to reach the most difficult test point in today's highly complex circuitry. The gold plated Probe Tips, Sprung Hook, Ground Lead, Alligator Tip and other critical interconnect points within the Gold Probe, provide excellent contacts for probing low level analog signals and high speed digital data. Unlike most "off shore" commodity probes, Probe Master guarantees quality and continuing domestic support for our "Made in America" Gold Probe.
-
product
Power Supplies
ZPG-1000B
80Plus Gold Certified provides typical 87% efficiency at 50% of max load. The ZPG series can give you the power you need at higher efficiency, which means you can use the same power with less energy. Built in QUAD 8-pin PCI-Express graphic card connector offering further upgradability.
-
product
Working Electrodes for Flow Cell
Our working electrodes for flow cell are mounted in blocks of PEEK. This resin protects the electrodes from external noise and allows researchers to utilize them regardless the content of mobile phase of HPLC because of their hardness and organic slovent-resistance. Glassy carbon is usually chosen for the redox reaction study on liquid chromatography. Platinum, Gold, Carbon paste and Nickel electrodes are utilized for special purporses.
-
product
High Force Type Prbobe For PCB, K100 Series 100 Mil Pitch, Receptacle
KR100
K100 Series, Pitch 100mil, Receptacle, no wire wrap pin. Brass with gold finish.
-
product
Plugbord
3662A6
VECTOR Electronics and Technology, Inc.
44 Gold plated edge contacts (22 each side)on 0.156"(3.96mm) centers.Overall Ground plane on one side with 0.085" diameterclearance around each hole. No pattern on reverse side.
-
product
Alchitry Cu FPGA Development Board (Lattice ICE40 HX)
If you are not needing a lot of power to start your FPGA adventure, or are looking for a more economical option, the Alchitry Cu FPGA Development Board might be the perfect option for you! The Alchitry Cu is a "lighter" FPGA version than the Alchitry Au but still offers something completely unique. FPGAs, or Field-Programmable Gate Arrays, are an advanced development board type for engineers and hobbyists alike to experience the next step in programming with electronics. The Cu truly exemplifies the trend of more affordable and increasingly powerful FPGA boards arriving each year. This board is a fantastic starting point into the world of FPGAs and the heart of your next project. Finally, now that this board is built by SparkFun, we added a Qwiic connector for easy I2C integration!
-
product
Scientific CCD Image Sensors
Our front and backside illuminated (BSI) and backthinned Charge Coupled Devices (CCDs) are seen as the gold standard for scientific and quantum imaging in applications in spectroscopy, microscopy, In vivo, x-ray and astronomy. We understand that every imaging application is unique and requires our engineers and scientists to work closely with our customers providing highly tailored imaging solutions.
-
product
Grid Electrode
Grid electrode is produced by the deposition of the platinum, gold or carbon onto the quartz glass. The dimension of the glass is 8 x 27 mm, with a 1 mm of the thickness, and the grid line is 100 m width with a distance of the 150 m between lines.
-
product
Micro Power, Contact, ITA, 21 Amp, 12-14 AWG
610143101
Primary mating contact 610142101. (May mate with other Receiver contacts, as well.)Specifications Operating Current 21 amps continuousContact Resistance 1.5 mOhms max.Dielectric Withstanding Voltage (DWV) 1500 VDC min.Contact Body BrassContact Plating 30µ" Au over 100µ" NiContact Termination CrimpCycle Life 10,000 cyclesRoHS Directive 2011/65/EU Status CompliantREACH Article 33 Status CompliantECHA Article 59 of Reach Regulation CompliantAVG Mating Force (lbs) 1.23u
-
product
Micro Coax, Contact, Receiver, 50 GHz
610140108
Primary mating contact 610141108. (May mate with other ITA contacts, as well.) *This contact sold as a patchcord only.Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 30µ" Au over 100µ" NiContact Termination Solder Nut ClampInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC-50GHzVSWR 1.06+0.004 f(GHz)Insertion Loss - .095 x √f(GHz) dBDWV 700 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications Flex 405Environmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
product
High Force Type Probe For PCB, K100 Series 100mil Pitch, Type H, Ø0.80mm, 155gf
K100-H080155-SKAU
K100 Series, Pitch 100mil, Tip Style H, Tip Diameter Ø0.80mm, Spring force 155gf, Steel with Gold Plating.
-
product
High Force Type Probe For PCB, K100 Series 100mil Pitch, Type I, Ø1.26mm, 230gf
K100-I126230-SKAU
K100 Series, Pitch 100mil, Tip Style I, Tip Diameter Ø1.26mm, Spring force 230gf, Steel with Gold Plating.
-
product
Standard Pitch Spring Probes
Other than spring probes with gold plating, we have spring probe with anti-solder migration coating and plating that were developed by KITA. We also have anti-solder migration material for plunger tip. These are all included in “MARATHON” series. They have wide range of tip type for various use for every popular total length.
-
product
Signal, Contact, Receiver, TriPaddle, 7 Amp, 20-24 AWG, Crimp/Solder
610110125
Signal, Contact, Receiver, TriPaddle, 7 Amp, 20-24 AWG, Crimp/Solder.p/n 610110125 TriPaddle Receiver 50µ" AU platingp/n 610110101 TriPaddle Receiver 30µ" AU platingThis contact primarily used in CASS applications.
-
product
Stator Test Systems
Automation Technology's STS-3800 has become the "gold standard" in Stator Testing Equipment. The STS-3800 is packed with standard features and like all of ATI's 3800 Series Test Systems, it is backed by the industry leading two-year limited warranty. The STS-3800 offers the most comprehensive testing of stators and fields available.
-
product
WR-8 Waveguide Straight
WAG-08-SXX
Precision mmw F-Band, WR-08, Straight waveguides are built with high precision and then gold plated for high corrosion resistance. They have very low loss and great VSWR. Manufactured to rigid specifications, these transmission line components provide minimum detrimental effects on the overall system VSWR.XX = length in inchesFeatures of WR-08, Waveguide Straights• 90 GHz to 140 GHz• Low Insertion Loss, typical for length• Low Return Loss, typical for length• UG-387 flangeView more WR-8 Waveguide Straight
-
product
PCI Adapter for cPCI
PCI2cPCI
PCI2cPCI is an adapter familiy used to mount a cPCI device into a PCI connector. PCI2cPCI-32, PCI2cPCI-32-IO, and PCI2cPCI-64 are passive devices with impedance controlled traces interconnecting the Gold Fingers of the PCI edge connector to the press fit cPCI connector. All PCI signals are routed through including power, ground, PCI bus, secondary control signals.
-
product
Mini Power, ITA, 36", 50u Gold (22 Amps), 16 AWG White Teflon (19 Amps), Single-Ended
7-243916000-036
Mini Power, ITA, 36", 50u Gold (22 Amps), 16 AWG White Teflon (19 Amps), Single-Ended
-
product
Radio Frequency Cable Tester
RFCT
Textron Systems’ Radio Frequency Cable Tester (RFCT) allows for on-site testing and maintenance for radio frequency (RF) transmission paths within a platform. Using preconfigured databases of sweep parameters and pass/fail criteria, the RFCT quickly determines the status of installed RF cables. The RFCT checks each cable’s performance characteristics to include voltage standing wave ratio (VSWR), insertion loss (IL), phase and phase matching. If a cable fails a test, the RFCT automatically determines the distance-to-fault (DTF). With its intuitive touchscreen-based user interface and lightweight, ruggedized packaging, the RFCT is the gold standard for operational-level RF cable testing.
-
product
Spectrophotometer - Spectrometer
Spectroscopy has a wide area of application in many fields. Spectroscopy is based on the concept of Energy = frequency x Planck (E=ʎh) constant which is used to study matter. Spectrometry is the technique which is used to analyze the concentration of elements in the sample being tested. Our products are able to analyze carbon, aluminum, sulfur, gold, silver, magnesium, steel, alloys and many other elements. We can also calibrate our products to account for elements like oxygen which are present in many compounds by calibrating with a known sample.
-
product
Trace Level Chemiluminescence NO-NOy Analyzer
Model T200U NOY
Teledyne Advanced Pollution Instrumentation
The Model T200U NOy analyzer has been developed and refined specifically to address the challenges of NOy monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is coupled with a remote NOy converter via umbilical to allow measurements with a lower detectable limit of 50 ppt.The Model T200U NOy analyzer combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer. The remote NOy converter is provided with a stainless steel, NEMA 4X (IP65) enclosure and custom sample umbilical to allow a mounting height of 10 meters. In addition, the converter features a unique purge circuit designed to remove residual calibration gas.
-
product
STD Bus, Vectorbord Plugbord
4610
VECTOR Electronics and Technology, Inc.
56 Gold plated edge contacts (28 each side)on 0.125"(3.175mm) centers. 3-Hole solder pads (0.28” x 0.080”) and buses forinterconnecting multiple component leads. Row and column legends provided.
-
product
Mini Coax, Contact, ITA, RG316
610103115
Primary mating contact 610104114. (May mate with other Receiver contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 30µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50 ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance < 5 mΩ @ 0.5 Amp & always < 10 mΩCable Specifications RG316Environmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
product
Inductor Products
Macom Technology Solutions Holdings Inc.
They provide uniformity, durability and repeatability in circuit fabrication. The coils are polyimide coated to protect from ambient contaminants, and to eliminate the need for conformal coating. Quartz substrates are rugged and reduce dielectric losses. Chips may be bonded using either conductive or non conductive epoxies, and wire bonded with gold wire or ribbon by thermocompression bonding.
-
product
Mini Coaxial Contact, Receiver, RG316 Double Shield
610104149
Mini Coaxial Contact, Receiver, RG316 Double Shield.Mechanical SpecificationsDurability 20,000 cyclesContact Material Shield – BrassCenter Conductor – BeCuContact Plating Shield – 50µ" Au over 100µ" NiCenter Conductor – 60µ" Au over 100µ" NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC to 1 GHzVSWR ≤ 1.06 @ 1 GhzInsertion Loss 1.2 dB @ 1 Ghz1.02 dB @ 500 MhzDWV 1500 VDC Min.Contact Resistance 5 mOhms center/ 3 mOhms outer Cable Specifications RG316 Double ShieldEnvironmental SpecificationsOperating Temperature -50°C to +105°CInsulation Resistance 1000 MΩ min.
-
product
Single Sided PCB
Amitron produces prototype, midrange and high volume Single Sided circuit boards, with a copper thickness from one to twenty ounces. Operating temperatures range from 130 C to 230 C. Single sided boards are available with surface finishes including Organic surface protectant (OSP), Immersion Silver, Tin, and Gold plating along with both leaded or lead-free Hot Air Solder Level (HASL).
-
product
Isothermal Titration Calorimeters
MicroCal ITC Range
The "Gold Standard" for measuring binding affinity and stoichiometry. MicroCal ITC isothermal titration calorimeters are used to study a wide range of biomolecular interactions. The applications range from drug design to fundamental research such as the understanding and regulation of signal transduction pathways. These systems deliver direct, label free and in-solution measurements of binding affinity and thermodynamic parameters in a single experiment. They have high sensitivity, low sample consumption and options for automation to minimize ‘hands on’ time. A choice of instruments ensures that MicroCal ITC calorimeters meet the varied and demanding requirements of today’s life science laboratories.
-
product
LUTHER & MAELZER BARE BOARD TEST PINS
SERIES LMP 78
Materials and Finishes MATERIAL: Heat treated beryllium copper FINISH: 24 Kt gold plate over hard electroless nickel