Product
PXI/PXIe Battery Simulator Module, 6-Channel With V/I Readback
41-752A-011
Simulator
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 6-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
Product
LED Load Simulator
63110A/ 63113A/63115A
Simulator
As shown on the V-I curve in figure 1, the LED has a forward voltage VF and a operating resistance (Rd). When using a resistor as loading, the V-I curve of the resistor is not able to simulate the V-I curve of the LED as shown in blue on figure 1. This may cause the LED driver to not start up due to the difference in V-I characteristic between the resistors and the LEDs. When using Electronic Loads, the CR and CV mode settings are set for when the LED is under stable operation and therefore, is unable to simulate turn on or PWM brightness control characteristics. This may cause the LED driver to function improperly or trigger it’s protection circuits. These testing requirements can be achieved when using a LEDs as a load; however, issues regarding the LED aging as well as different LED drivers may require different types of LEDs or a number of LEDs. This makes it inconvenient for mass production testing.
-
Product
PCI Strain Gauge Simulator Card, 6-Channel, 350 Ohm
50-265-016
Strain Gauge Simulator
These cards simulates the operation of a range of strain gauges making them ideal for testing strain gauge meters and a wide variety of industrial control systems. They provide a simple way of replacing in house developed sensors with a low cost simulator having excellent performance that is easy to calibrate and use.
-
Product
PXI/PXIe Battery Simulator Module, 6-Channel, 1 KV Isolation
41-752A-101
Battery Simulator
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 6-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture. The 750 V or 1 kV isolation barrier (version dependent) allows the module to be used as a lower power version of a battery stack, representative of those used for vehicle propulsion.
-
Product
Battery Simulator SoftPanel
A170202
Battery Simulator
For the products developed to connect batteries for use, if the battery is not ready or unable to be provided due to high cost, the 17020 battery simulator can be used to confirming the product functions during development. The applications of battery simulator include motor drives within the car system, OBC, D-D convertor or charger within the CSS system and products of DC bus, etc.
-
Product
PXI Strain Gauge Simulator Module 6-Channel, 350
40-265-016
Strain Gauge Simulator
The 40-265 range consists of 6, 4 or 2 channel modules (this version is the 6-channel, 350Ω) that simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. The range provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance. The 40-265 uses the same resistor bridge techniques that real life strain gauges are based on, ensuring accurate emulation under all conditions.
-
Product
GPS Simulator
ADIVIC MP6220
Simulator
Multi-channel GPS simulator for GPS receiver position fix testIndividual channel is power adjustableSingle channel mode for receiver S/N ratio testTunable power output level from -160dBm to -55dBm
-
Product
PXI RTD Simulator Module, 16 Channel, PT100
40-263-201
Simulator
The 40-263-201 is a 16-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
PXI RTD Simulator Module 18 Channel PT100
40-262-001
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the design principles of our 40-260 PXI Precision Resistor, this RTD simulator module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels.
-
Product
PXI/PXIe Battery Simulator Module, 2-Channel, 1 kV Isolation
43-752A-103
Battery Simulator
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
Product
PCI Strain Gauge Simulator Card, 6-Channel, 1k
50-265-206
Strain Gauge Simulator
These cards simulates the operation of a range of strain gauges making them ideal for testing strain gauge meters and a wide variety of industrial control systems. They provide a simple way of replacing in house developed sensors with a low cost simulator having excellent performance that is easy to calibrate and use.
-
Product
PXI RTD Simulator Module 12 Channel PT100
40-262-201
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the design principles of our 40-260 PXI Precision Resistor, this RTD simulator module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels.
-
Product
PXI Strain Gauge Simulator Module 6-Channel, 1.5k
40-265-406
Strain Gauge Simulator
The 40-265 range consists of 6, 4 or 2 channel modules (this version is the 6-channel, 1.5kΩ) that simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. The range provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance. The 40-265 uses the same resistor bridge techniques that real life strain gauges are based on, ensuring accurate emulation under all conditions.
-
Product
Dual Port Simulator Fiber Channel XMC Module
XMC-FC4 Simulyzer
Simulator
*Two independent fiber channel ports*The two SFPs accept electrical as well as optical transceivers*Each port supports 1, 2, or 4 Gbps*Supports customer-specific defined transmission speed*Comprehensive decoding of FC-1, FC-2 and Upper Layer Protocol (ULP) frames*Triggering and filtering*Supports DMA for high-speed streaming*IRIG-B time code encoder / decoder for data correlation*Supports ULPs such as FC-AE-ASM, FC-AE-RDMA, FC-AE-1553 and FC-AV*Supports HS-1760E applications such as AS5653, AS5652 and AS5627*Optional fcXplorer, Windows-based FC simulation and analysis test software*FC SDK (Software Development Kit) provides drivers and APIs for Windows XP / 7,*Linux, VxWorks, QNX Neutrino RTOS and others on request
-
Product
PXI Millivolt Thermocouple Simulator Module - 24 Channel
41-760-002
Simulator
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
Product
PXI RTD Simulator Module, 12 Channel, PT500
40-263-302
Simulator
The 40-263-302 is a 12-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
PCI Strain Gauge Simulator Card, 6-Channel, 1.5k
50-265-406
Strain Gauge Simulator
Designed to simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. It provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance that is easy to calibrate and use.
-
Product
PXI/PXIe LVDT/RVDT/Resolver Simulator Module, 2-Banks
41-670-003-AABBCC
Simulator
The 41/43-670-003 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as resolvers. It has two banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal. This allows the module to simulate up to 2 channels of 5 or 6-wire or 4 channels of 4-wire.
-
Product
Grid Simulators
Simulator
A grid simulator can be used to simulate the characteristics of low-voltage mains. For this purpose, all voltages and frequencies of the supply networks occurring worldwide can be simulated. Critical states such as short-term voltage dips or voltage peaks (surge/burst) can also be generated.The integrated sequencer function enables the generation of different network parameters, e.g. distorted waveforms and intermediate oscillations. Therefore, grid simulators are well suited for testing conformity to standards and especially for determining the behaviour of electrical equipment in borderline situations. Many European and other international standards are pre-programmed for testing.
-
Product
PXI Strain Gauge Simulator Module 6-Channel, 1k
40-265-206
Strain Gauge Simulator
The 40-265 range consists of 6, 4 or 2 channel modules (this version is the 6-channel, 1kΩ) that simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. The range provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance. The 40-265 uses the same resistor bridge techniques that real life strain gauges are based on, ensuring accurate emulation under all conditions.
-
Product
Dual Port Simulator Fiber Channel PCI Module
PCI-FC4 Simulyzer
Simulator
The modules are available as a single-function board - for analysis or for simulation / data generation - but also as a full-function board for simultaneous analysis and simulation. By simply upgrading the firmware / software, a single function board can become a full function board without having to purchase new hardware.
-
Product
Dual Port Simulator Fiber Channel PXIe Module
PXIe-FC4 Simulyzer
Simulator
The modules are available as a single-function board - for analysis or for simulation / data generation - but also as a full-function board for simultaneous analysis and simulation. By simply upgrading the firmware / software, a single function board can become a full function board without having to purchase new hardware.
-
Product
PXI Millivolt Thermocouple Simulator Module - 32 Channel
41-760-001
Simulator
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
Product
Battery Simulator
1200
Battery Simulator
The Battery Simulator 1200 provides isolated channels to simulate battery sink and source characteristics often used for testing a Battery Management System (BMS). The instrument can be used standalone with the soft front panel, or integrated into a larger test system. Its proper industrial cooling and cell channel isolation allows units to be easily stacked, providing solutions with over 200 channels of simulation capability. The built-in channel voltage and current readback reduces the need for external monitoring equipment.
-
Product
PXI/PXIe Battery Simulator Module, 4-Channel, Simplified Current Sink, 750 V Isolation
43-752A-902
Battery Simulator
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 4-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
Product
ARINC825 (CAN Bus) Test & Simulation Module for CPCI With 2 Or 4 CAN Bus Nodes
ACC825-3U-x
Simulator
ARINC825 (CAN bus) Test & Simulation module for CPCI with 2 or 4 electrically isolated CAN bus nodes operating concurrently at CAN bus high speed bit rate of up to 1Mbit/s. The ACC825-3U-x CPCI card can work either with full functionality as an active CAN node for testing and simulating or in Listening Only mode for monitoring and recording purposes.
-
Product
PXI RTD Simulator Module, 12 Channel, PT100
40-263-301
Simulator
The 40-263-301 is a 12-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
CPCIe (PXIe) Module
ACS-FC-3U-2
Simulator
The ACS-FC-3U-2 is AIM’s high performance CPCIe (PXIe) module offering 2 ports with full function test, simulation, monitoring and analyzer functions for Fibre Channel networks. The ACS-FC-3U-2 is a powerful State-of-the-Art 4-lane CPCIe 2.0 compliant CPCIe board.
-
Product
PXI RTD Simulator Module, 24 Channel, PT100
40-263-001
Simulator
The 40-263-001 is a 24-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
PXI Strain Gauge Simulator Module 4-Channel, 1.5k
40-265-404
Strain Gauge Simulator
The 40-265 range consists of 6, 4 or 2 channel modules (this version is the 4-channel, 1.5kΩ) that simulate the operation of a range of strain gauges making it ideal for testing strain gauge meters and a wide variety of industrial control systems. The range provides a simple way of replacing in house developed sensors with a low cost simulator having excellent performance. The 40-265 uses the same resistor bridge techniques that real life strain gauges are based on, ensuring accurate emulation under all conditions.