ndb Technologies Inc.
ndb Technologies core business is the development and marketing of portable, high technology, test and measurement equipment for the electrical utility market.
- 1 (418) 877-7701
- 1 (418) 877-7787
- mkt@ndbtech.com
- sales@ndbtech.com
- 111-1405 Ave. St-Jean-Baptiste suite 111
Quebec City, QC G2E 5K2
Canada
-
product
High Frequency Current Transformer Clamps
HFCT-20HD & HFCT-60HD™
The HFCT-20HD™ and HFCT-60HD™ are high frequency current transformer sensors designed for partial discharge detection on electric apparatus’ ground returns. Made from superior quality materials, it is designed for any environment.
-
product
Partial discharge measurement with remote wireless reading
PD-LT
The PD-LT allows online partial discharge detection on cable accessories such as cable head for safety and maintenance purposes.The PD-LT indicates the intensity of the partial discharges, converting the electrical charge units (pC) into decibels (dB). Thus the reading is kept as a simple intensity level indication, proportional to the probability of a fault's presence in the tested medium voltage accessory.The remote display gives a dB value of the probe's measurement. The dB value will vary along with the discharges indicators on the PD-LT probe. The measurement range is from 0 to 65dB and the display will show ''OL'' if the reading is over 65dB.
-
product
Current Transformer Tester
CTT
The CTT is designed to test the current transformer ratio, Phase shift, Polarity, Excitation, Saturation, Winding resistance and Insulation resistance using the voltage method in compliance with ANSI/IEEE C57.13.1 and IEC 60044-1 standards, where voltage is applied to the secondary X terminals of the current transformer.
-
product
Energized Cable Identification System
LCI™
The LCI™ system is intended for energized cable identification on secondary and primary circuits. This innovative solution features a dual frequency technique that eliminates false identifications. The LCI™ is designed to be easy to use, safe for the user and cost-effective.
-
product
High Precision Digital 10A Mirco-Ohmmeter
DRM-10A™
The DRM-10A™ is a lightweight and portable micro-ohmmeter designed to measure very low resistances from 0.01 μΩ to 200 Ω. It is the most accurate in its category.
-
product
True Phase Identification System
SPI-III™
Our vision has always been to create a phase identification system that exceeds any of today’s industry quality, safety and efficiency requirements. SPI-III’s unique design consists of a wireless bi-module combo that is stunningly easy to configure and operate. With many advancements and innovations, SPI-III will be more helpful than ever before, enabling field applications such as identification of A-B-C electrical phases from all 50 and 60 Hz networks, switchgear phase concordance (matching), phase rotation, system paralleling, underground phasing applications and more.
-
product
Ultrasonic Corona & Arcing Detector
ULD-40™
The ULD-40™ is an ultrasonic detector designed for corona effect and arcing detection for predictive maintenance in electric utilities. Available with a variety of accessories, this instrument is a cost-effective must for any prevention plan.
-
product
Distribution Transformer Tester
NDB-DOC™
The NDB-DOC™ is a test instrument designed for distribution networks transformers from 10kVA to 2500kVA. It can determine the presence of short circuits or an open circuit in the distribution transformer primary winding & also short circuits on the secondary winding. The NDB-DOC™ is designed to be operated from an arial device or from the ground at the end of a hot stick without disconnecting the transformer’s secondary windings.
-
product
Distribution Transformer Tester
NDB-DOC-3™
The NDB-DOC-3™ is a test instrument designed for distribution networks transformers from 5kVA to 3MVA. It can determine the presence of short circuits or open circuits in the distribution transformer primary winding & also short circuits on the secondary winding.The NDB-DOC-3™ is designed to be operated without disconnecting the transformer’s secondary windings from their loads.
-
product
Contact Resistance Measurement Kit
LRM-10
The LRM-10 is a 10A micro-ohmmeter kit designed to measure low resistance for electrical interconnections integrity testing. The LRM-10 has a range from 0.01µΩ to 200Ω. It comes with heavy duty four points probes and it is compatible with a great variety of optional accessories.
-
product
Expert Partial Discharge Detector
XDP-II™
The well-established XDP-II™ is a battery-operated portable device allowing partial discharge detection and analysis. The data is saved in its internal memory for local or further analysis on the PC-based XDP-SOFT™. Paired with the proper accessories, the XDP-II™ becomes a powerful solution for many applications such as Cable Joints and Elbows, Switchgear, Offline, Acoustic, TEV, Rotating machines, Transformer, etc…
-
product
Cable Identification & Phasing
VCi-3™
The VCi-3™ system is designed for cable and phase identification, mainly for installation or maintenance purposes on three-phase electrical networks during power shutdowns.The transmitter module injects a low current on the cable conductors by direct contact or magnetic clamps methods. A voice message is recorded by the user and will be transmitted along with digital signals. Groundings stay connected at both ends of the three-phase circuit during the test. The detector module is used at the other end of the cable system.
-
product
Winding Resistance Tester with Demagnetisation Circuit
WRT-10D
The WRT-10D is a high performance winding resistance tester designed for power transformer and large motor applications. It is equipped with a bright LCD display, a rugged high quality cable set, a built-in printer, a full QWERTY keypad and a demagnetisation circuit.
-
product
Distribution Transformer Tester
DOC-2000™
The DOC-2000™ is a test instrument designed for distribution networks transformers up to 167KVA. It can determine the presence of short circuits or an open circuit in the distribution transformer primary winding & also short circuits on the secondary winding. The DOC-2000™ is designed to be operated from an arial device or from the ground at the end of a hot stick without disconnecting the transformer’s secondary windings.