Hilkar, combines extensive research and development with high quality systems in both manufacturing and design processes. In addition to this, an extensive sales organization and experienced customer response have founded. Today, dedicated to serving our customers in Turkey and abroad, Hilkar is one of the main power resistors, reactors, special transformers and motor control and testing systems supplier in the world.
- +90 264 275 5540
- +90 264 275 1276
- hilkar@hilkar.com
- Organize Sanayi Bolgesi 10.Cad. No:9
Arifiye/Sakarya, 54580
Turkiye
-
Product
Grounding Transformers [ZN (Zigzag), ZNyn, YNd(open), Ii0]
-
Grounding Transformers are designed for providing an artificial neutral point for ungrounded three phase power systems. During the line-to-ground faults, grounding transformers provide an easy path to ground faults to limit the fault currents and transient overvoltages.
-
Product
Neutral Grounding Resistors
NGR
-
Neutral Grounding Resistors (NGRs) are used to limit the fault current for safety of equipment and personnel in industrial systems.
-
Product
LV Iron Core Harmonic Filters
-
Nonlinear loads such as power electronics based equipment and electric furnaces are sources of harmonic currents leading to harmonic distortion, which is one of the most important parameters for defining the power quality. Most of the commercial loads such as personal computers, photocopy machines, power supplies, and compact fluorescent lamps; and industrial loads such as AC and DC motor drives inject harmonic currents into the network that they are connected to.
-
Product
Combined Load Banks
C-Series
-
C-series combined load banks are devices which contain resistive and reactive loads, apply the load to an electrical power source and dissipate the power of the electrical power.
-
Product
Dynamic Braking Resistors
-
Speed of three phase asynchronous squirrel-cage motors and three phase synchronous motors are generally controlled by motor drives where frequency of the drive output determines the motor speed, and it can be adjusted without dependence on the voltage magnitude.
-
Product
dv/dt Filters
-
dV/dT Output Filter Modules effectively protect motors against these high voltage spikes due to the use of motor cables between IGBT based motor drives and motors.
-
Product
Air Core Test Lab Reactors
-
Test Laboratory Reactors are designed for high voltage and high power test laboratories. They are designed to withstand the most extreme electrical service conditions during test periods. Design techniques are implemented in accordance with the most demanding service conditions. These reactors are used for various purposes in test laboratories such as current limiting and synthetic testing of circuit breakers, capacitor testing, artificial line simulation etc.
-
Product
Explosion-Proof Heaters
-
Explosion-Proof Heaters (ATEX certified) provide neutral convection solutions of heating for electrical equipments in hazardous industrial locations where potential for explosion exists due to the presence of flammable gases, vapors, powder-metals or dusts.
-
Product
LV Iron Core Motor Starting Reactors
-
Motor starting reactors are used to reduce voltage during starting of large 3 phase motors while limiting inrush currents.
-
Product
Slip-Ring Motor Starting Panels
Rotor Starter
-
The Slip-Ring Motor Starters are based on the series of resistors that are applied to the rotor circuit to control the speed/torque characteristics of the motor. Rotor starters are mainly used for the motor starting applications requiring high-starting torque like loaded belt conveyors in mining industry. By external resistors, it is possible to shift the motor maximum (break-down) torque up to starting torque point for motors under heavy loads during start-up. The resistors are splitted into some steps and controlled via contactors by motor starting control system. As the motor speed increases, the external rotor resistors are eliminated by shorting contactors until all external resistors are shorted out.
-
Product
Motor Starting Auto-Transformers
-
Motor Starting Auto-Transformers reduce the inrush current by stepping down the applied voltage during the start-up operation of induction and synchronous motors.
-
Product
Crowbar Resistors
-
Crowbar resistors are three phase resistance banks which are connected to the rotor windings of the DFIG (Doubly-Feed Induction Generator) such as wind power generator. They are used to prevent damage to the inverter circuits attached to rotor side when a fault occurs in the grid. DFIG power converter, which has a restricted over-current limit, needs special attention during faults in the grid. If the rotor current or DC link voltage reaches the threshold value, crowbar resistors disconnect the converter in order to prevent the generator turning into a squirrel cage induction machine. By crowbar resistors, the DFIG could stay connected to the grid and continue its operation.
-
Product
Harmonic Filter Resistors
-
The widespread use of nonlinear loads such as power electronics based equipment and electric arc & ladle melt furnaces all around the world hinder the quality of electric power. One of the most important parameters for defining the power quality is harmonic distortion.
-
Product
Primary Current Injection Testers
-
Primary Current Injection Tester is designed for testing protective relay and circuit breakers and also testing the turns ratio of current transformers at high variable currents. A test current is injected into the primary side of a system to determine how the system behaves at particular levels of current. This test makes it possible to determine whether the relay will trip and how long the current needs to flow before the trip is initiated.
-
Product
High Resistance Neutral Grounding Devices
-
HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.